Abdallah, S., Wilkinson-Maitland, C., Waskiw-Ford, M., Abdallah, I., Lui, A., Smith, B., Bourbeau, J., & Jensen, D. (2017). Late Breaking Abstract - Validation of Hexoskin biometric technology to monitor ventilatory responses at rest and during exercise in COPD. European Respiratory Journal, 50(Suppl. 61), PA1359. https://doi.org/10.1183/1393003.congress-2017.PA1359
SummaryIn the gait experiment, 19 healthy college students aged 18–21 years (10 male and 9 female) completed six over-ground walks covering a distance of four meters at self-determined slow, medium, and fast speeds in a motion-capture laboratory. Hexoskin supplied tri-axial acceleration at 64 Hz; its other sensor data were not analyzed. The experiment compared the eyeglass-camera system and the body-worn accelerometer with 20-camera optical motion capture for classifying gait speed. Separately, the dissertation describes a video-based Fuzzy Inference System that uses video features and identified objects to classify activities.
Key FindingIn the gait experiment, the eyeglass-camera system significantly discriminated gait speed and outperformed the vest-based accelerometer, while motion capture provided superior gait-speed discrimination. The glasses-derived frontal-plane data distinguished slow, medium, and fast speeds in all reported pairwise comparisons (all p < .05); the accelerometer's vertical-plane data did not (p = .26). Separately, a video-based Fuzzy Inference System reported 74% overall activity-classification accuracy, but the dissertation cautions against direct comparison with systems that produce one definitive action label.
Abed, M., & Ibrikci, T. (2023). Sleep apnea events detection using deep learning techniques. Journal of Sleep Disorders: Treatment and Care, 12(1), 101. https://doi.org/10.4172/2325-9639.23.12.101
Breen, M., Reed, T., Breen, H. M., Osborne, C. T., & Breen, M. S. (2022). Integrating wearable sensors and video to determine microlocation-specific physiologic and motion biometrics-method development for competitive climbing. Sensors, 22, Article 6271. https://doi.org/10.3390/s22166271
SummaryThis study developed a method for examining time-resolved biometrics in relation to climbing strategy, technique, and position on an indoor wall. Continuous Hexoskin measurements and smartphone video were time-matched so heart rate, breathing rate, minute ventilation, and hip acceleration could be viewed at specific positions along the route. An interactive interface supported review of biometric changes at key events and calculation of summary statistics. The illustrated demonstration was a 530 s (8:50, min:sec) lead climb on a 16.8 m (55 ft) indoor wall.
Key FindingDuring a 530-second lead climb monitored with Hexoskin, heart rate consistently increased during active climbing and decreased during rest, while breathing rate varied less consistently. Hip-acceleration peaks up to 0.36 g corresponded to active climbing, and sustained values of 0.01–0.08 g corresponded to rest. In a difficult 46–151 s section, heart rate, breathing rate, and minute ventilation all rose substantially; these descriptive results support the feasibility of linking sensor data with climbing video, and they do not show that a training intervention improved performance.
Abid, M., Khabou, A., Ouakrim, Y., Watel, H., Chemcki, S., Mitiche, A., Benazza-Benyahia, A., & Mezghani, N. (2021). Physical Activity Recognition Based on a Parallel Approach for an Ensemble of Machine Learning and Deep Learning Classifiers. Sensors, 21(14), 4713. https://doi.org/10.3390/s21144713
SummaryAbid and colleagues investigated inter-subject human-activity recognition from acceleration data collected with a Hexoskin shirt. They compared three classification pipelines based on handcrafted features with ReliefF and SVM, LDA with KNN, and a multivariate CNN, then combined them in an ensemble for ten static, dynamic and hazardous activities. The ensemble reported weighted-average precision, recall and F1 scores of about 99%, while parallel processing shortened segmentation and GPU execution accelerated the CNN under the reported setup.
Key FindingFor activity recognition from Hexoskin acceleration, the multivariate CNN and the three-pipeline ensemble each reported weighted-average precision, recall and F1 scores of about 99% across their evaluated activity classes. The ensemble covered ten activities, and under the reported setup, parallel processing made segmentation almost five times faster while GPU execution made the CNN about 80 times faster than CPU execution.
Hopenfeld, B. (2022). Peak space motion artifact cancellation applied to textile electrode waist electrocardiograms recorded during outdoors walking and jogging [Preprint]. bioRxiv. https://doi.org/10.1101/2022.01.07.475456
SummaryThis single-participant preprint evaluated a peak-space motion-artifact cancellation method for waist textile ECG during outdoor walking and jogging. A 54-year-old man completed four sessions on different days, each with approximately 20–25 minutes of walking and jogging. Hexoskin chest ECG served as the reference for waist ECG recorded with a Zephyr Bioharness.
Key FindingProcessed waist ECG generally tracked the Hexoskin chest-reference heart rate during walking and jogging, but tracking deteriorated during two approximately five-minute poor-quality periods. Artifact cancellation was less complete during walking than jogging. A secure waistband fit remained necessary because the method could not recover QRS complexes fully obscured by motion artifact; results come from one participant, and RMSSD agreement applies only to acceptable-quality segments.
Raw signals
ECG
Data channels
RR Interval
Metrics
RMSSD
HexoskinArticleNeuroscience, Sleep & CognitionOccupational Health & Human FactorsData Science & Artificial Intelligence
Ahmed, S., Deneke, W., Mai, V., Veneruso, A., Stepita, M., Dawson, A., Hoefel, B., Claeys, G., Lam, N., & Sharmin, M. (2020). InterViewR: A Mixed-Reality Based Interview Training Simulation Platform for Individuals with Autism. In 2020 IEEE 44th Annual Computers, Software, and Applications Conference (COMPSAC) (pp. 439-448). IEEE. https://doi.org/10.1109/COMPSAC48688.2020.0-211
SummaryAhmed and colleagues developed InterViewR to address limitations in digital interview training for individuals with Autism by combining an immersive virtual-reality interview with a Hexoskin smart shirt. Hexoskin captured RR intervals and breathing rate so the platform could present real-time affective feedback and help users recognize stress during different parts of an interview. The user evaluation examined feasibility, usability, and perceived usefulness, and the authors reported that the mixed-reality platform elicited genuine stress responses while providing coherent feedback on interview skills.
Key FindingInterViewR combined immersive virtual-reality interview practice with Hexoskin-based affective feedback, and the authors reported that it elicited stress responses and provided coherent feedback on interview performance. In a separate 11-person usability evaluation, none of the participants had Autism; they considered the system useful for interview training but did not expect to use it frequently. Suggested improvements included a more human-like interviewer, more varied settings, clearer feedback and objective performance scoring.
Rogers, B. (2020). A personalized low intensity exercise prescription based on an index of non-linear heart rate variability: A case report. Journal of Athletic Enhancement, 9(1). https://doi.org/10.37532/jae.2020.9(1).327
SummaryThis single-participant case report examined DFA a1, a nonlinear heart-rate-variability index, during cycling in a 62-year-old male recreational cyclist. It compared progressive five-minute intervals with and without 25 mg Atenolol and longer 10-minute intervals near the first ventilatory threshold. Hexoskin supplied heart-rate and R–R interval recordings, which were analyzed alongside ventilation and cycling workload.
Key FindingHeart rate measured with Hexoskin was 15–20 bpm lower at each power stage with Atenolol, while DFA a1 declined similarly with increasing cycling power in the control and Atenolol trials. At roughly 125 bpm, DFA a1 was 0.336 during Atenolol cycling and 0.723 during the control ramp at different workloads. These observations distinguish matching heart rate from matching workload in this individual; they do not establish universal training thresholds.
Ahn, H., & Ko, J. (2022). The Effect of Olfactory Inhalation on KPGA Golfers’ Putting Performance, Postural Stability and Heart Rate. International Journal of Environmental Research and Public Health, 19(19), 12666. https://doi.org/10.3390/ijerph191912666
SummaryTen professional golfers completed 3-metre putting tasks under control, lavender, citrus, and ammonia conditions. A Hexoskin biometric shirt recorded heart-rate changes, while a force plate measured centre-of-pressure area. Olfactory inhalation produced no significant difference in putting success or heart rate, but postural-stability differences were significant in the address, downswing, and total putting sections.
Key FindingIn ten professional golfers, olfactory inhalation did not significantly change putting success (p = 0.115) or heart rate recorded by Hexoskin during the address, putting, or total phases (p = 0.838, 0.878, and 0.666). Postural stability measured by centre-of-pressure area was significantly inhibited in the address, downswing, and total putting sections (p = 0.000, 0.035, and 0.047).
Data channels
Heart Rate
HexoskinArticleCardiology & ArrhythmiaClinical Medicine & SurgeryNeuroscience, Sleep & Cognition
Brunet, J., Wurz, A., Hussien, J., Pitman, A., Conte, E., Ennis, J. K., Herry, C. L., Seely, A. J. E., & Seely, D. (2022). Exploring the effects of yoga therapy on heart rate variability and patient-reported outcomes after cancer treatment: A study protocol. Integrative Cancer Therapies, 21, 1–13. https://doi.org/10.1177/15347354221075576
SummaryThis protocol describes an exploratory single-subject study of yoga therapy after cancer treatment. Twenty-five adults were recruited and six dropouts were reported. The program comprised one individual yoga-therapy session and six weekly group sessions, with seven assessments from baseline through follow-up. Hexoskin shirts recorded ECG and respiratory data at assessment visits, and hierarchical linear modeling was planned for heart-rate variability and patient-reported outcomes. The publication reports a protocol rather than efficacy results.
Key FindingThis yoga therapy protocol used Hexoskin to monitor participants after cancer treatment; it reports no efficacy results. It describes a single-subject design with 25 recruited adults and six dropouts, using heart-rate variability as the primary outcome and fatigue, anxiety, depression, stress, perceived cognitive function and quality of life as secondary outcomes.
Mujaddid, A. (2023). Responsiveness of the Hexoskin Smart Shirt to detect pharmacological lung volume reduction at rest and during exercise in people with chronic obstructive pulmonary disease (COPD) [Master's thesis, McGill University]. eScholarship@McGill. https://doi.org/10.82308/3155
SummarySix adults with chronic obstructive pulmonary disease completed stair-stepping tests before and after bronchodilator treatment while wearing Hexoskin. Researchers compared the shirt with a Vmax metabolic cart; poor shirt signal quality excluded one participant from the main analysis. Tidal volume, minute ventilation and respiratory rate correlated between devices, but inspiratory capacity and inspiratory reserve volume did not. Changes after bronchodilator treatment did not correlate significantly between devices.
Key FindingIn five analyzable participants with COPD, Hexoskin tracked changes in breathing pattern during stair stepping, but the comparison with Vmax did not support using the shirt to detect bronchodilator-induced changes in operating lung volumes.
Raw signals
Respiration
Data channels
Breathing RateMinute VentilationTidal Volume
HexoskinArticleClinical Medicine & SurgeryNeuroscience, Sleep & Cognition
Brunet, J., Hussien, J., Pitman, A., Wurz, A., Conte, E., Polskaia, N., & Seely, D. (2024). Yoga therapy as an intervention to improve patient-reported outcomes among adults after treatment for cancer: Preliminary findings from a trial using single-subject experimental design. Integrative Cancer Therapies, 23, 1–14. https://doi.org/10.1177/15347354241233517
SummaryThis exploratory single-subject study analyzed 20 of 25 enrolled adults after cancer treatment. Participants received one individual yoga-therapy session and six weekly small-group sessions, with patient-reported fatigue, anxiety, cognitive function, depression, stress, and quality of life measured across phases. Hierarchical linear modeling compared changes over time. The article reports preliminary patient-reported outcomes rather than garment-derived physiological findings.
Key FindingThe authors reported that cancer-related fatigue and state anxiety increased immediately after the individual session but improved more during the subsequent group-intervention phase. Trait anxiety, perceived cognitive impairment, its impact on quality of life, and functional wellbeing also improved over time, while the remaining patient-reported outcomes did not change. These exploratory findings require confirmation in controlled trials and do not provide garment-derived physiological outcomes.
HexoskinArticleOccupational Health & Human Factors
Bull, R., Wong, S., MacQuarrie, A., Katrakazos, E., Cumming, T., & McFarland, L. (2026). Early childhood educators’ well-being and physiological stress in the workplace: An exploratory study utilizing wearable technology. International Journal of Stress Management, 33(1), 55–66. https://doi.org/10.1037/str0000381
SummaryThis exploratory study combined psychological surveys with Hexoskin HRV monitoring in Australian early childhood educators. One hundred educators were recruited, and 68 had usable physiological data after cleaning. A common four-hour window from 10:00 a.m. to 2:00 p.m. was analyzed across work shifts; it was not a uniform total wear duration.
Key FindingIn a study pairing questionnaires with Hexoskin heart-rate variability monitoring, educators reported poorer functioning than normative data for emotional role limitations, energy/fatigue, and social functioning (BF10 > 100); this self-report comparison does not establish a physiological burnout marker. The mental-health association with RMSSD was small (τb = 0.17, p < .05) with anecdotal Bayesian support (BF10 = 2.25). Work–family conflict associations with RMSSD and HF power became nonsignificant after controlling for age, and the paper reported evidence against a relationship between burnout scores and physiological measures.
Data channels
RR Interval
Metrics
RMSSD
HexoskinConference AbstractCardiology & ArrhythmiaClinical Medicine & SurgeryValidation & Methodology
Alalool, A., Dubeau, S., Shu, Y., Roy, J.-F., Fournier, P.-A., Crystal, E., & Cheung, C. (2024). Comparative Analysis of a Wearable Electrocardiograph Reporting Technology and Holter Monitor in Cardiac Monitoring: A Prospective Study. Canadian Journal of Cardiology, 40, S67. https://doi.org/10.1016/j.cjca.2024.08.104
Buregeya, J. M., Apparicio, P., & Gelb, J. (2020). Short-term impact of traffic-related particulate matter and noise exposure on cardiac function. International Journal of Environmental Research and Public Health, 17(4), Article 1220. https://doi.org/10.3390/ijerph17041220
SummaryThis exploratory study followed four healthy young cyclists aged 25–37 years in Montreal over five days to examine traffic-related particulate-matter and noise exposure alongside pre- and post-cycling cardiac measures. Hexoskin supplied continuous ECG during 40-minute sitting periods and minute ventilation used with Aeroqual pollutant concentrations to estimate inhaled dose. Bayesian models analyzed 255 five-minute RR-interval segments.
Key FindingPM2.5 and PM10 doses estimated using environmental sensors and Hexoskin minute ventilation were highly correlated (r = 0.98), so the authors retained PM2.5 for subsequent analysis. Separate models reported associations of higher cumulative PM2.5 and noise dose with greater heart-rate variation, but the noise association disappeared when PM2.5 entered the combined model. The authors reported no HRV effect and cautioned against generalizing from four participants; the source's Bayes-factor interpretation is internally inconsistent, so no evidence-strength direction is assigned here.
Raw signals
ECG
Data channels
Heart RateMinute VentilationRR Interval
Metrics
RMSSDSDNN
AstroskinArticleCardiology & ArrhythmiaClinical Medicine & SurgeryValidation & Methodology
MacQuarrie, A., Sidhu, J., Deetlefs, C., Whitfield, S., & Stainer, M. (2024). Establishing the Validity and Reliability of the Astroskin® Biometric Shirt. Topics in Exercise Science and Kinesiology, 5(1), Article 4. https://doi.org/10.9741/2766-2187.1078
SummaryMacQuarrie and colleagues compared Astroskin with the hospital-grade corpuls3 monitor in 24 participants during a seated 22-minute session; 19 returned for a second seated session. Heart rate and systolic blood pressure showed low error, strong concordance, and comparable between-session reliability. Oxygen-saturation error was low, but concordance and reliability were weaker, identifying SpO2 sensor placement and performance across a wider physiological range as areas for further study.
Key FindingAstroskin heart rate and systolic blood pressure showed low error, strong agreement with corpuls3, and comparable reliability across sessions. SpO2 error was low, but concordance and reliability were weaker, potentially reflecting limited variability and sensor placement.
Data channels
Heart RateSpO₂Systolic Pressure
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human Factors
Burnett, R. A., Matheson, D. J., Kapron, C. R., Blackburn, B. E., Gililland, J. M., Anderson, L. A., Pelt, C. E., Peters, C. L., & Archibeck, M. J. (2025). Conversion total knee and hip arthroplasty requires increased energy expenditure compared to primary knee arthroplasty. The Journal of Arthroplasty. Advance online publication. https://doi.org/10.1016/j.arth.2025.11.003
SummaryFive orthopaedic surgeons wore Hexoskin garments during 179 joint-replacement operations to examine physiological workload across simple primary, conversion/complex primary, and revision knee and hip arthroplasty. The garment-derived outcomes were heart rate, minute ventilation, and energy expenditure. The patient case counts and demographics describe the operations, not the five monitored surgeons.
Key FindingIn five surgeons monitored with Hexoskin across 179 joint replacements, energy expenditure was descriptively higher during conversion/complex primary and revision arthroplasty than during simple primary procedures. After accounting for surgeon differences and patient BMI, complex primary knee arthroplasty remained higher than simple primary knee arthroplasty (β = 166.2, SE 60.7; P = 0.0073), whereas the corresponding hip comparison was not significant (P = 0.17). Heart rate and minute ventilation showed no significant overall group differences.
Data channels
Heart RateMinute Ventilation
HexoskinAcademic ThesisExercise Physiology & Sports ScienceOccupational Health & Human FactorsValidation & Methodology
Sherman, A. R. (2015). System Safety Analysis of the Opelika Fire Department's Crawling Simulator [Master's thesis, Auburn University]. Auburn University Electronic Theses and Dissertations. https://etd.auburn.edu/handle/10415/4901
SummarySherman's system-safety study examined a crawling training device used by East Alabama fire departments, where reducing training-related injury risk was the central objective. The analysis proposed Hexoskin for remote physiological monitoring alongside infrared cameras and modeled it as a failsafe in the simulator fault tree. The model estimated that these additions would reduce the failure-mode detection score to 4 and the risk-priority number from 144 to 72; this was a modeled result, not a prospective validation with firefighter trainees.
Key FindingThe safety model estimated that adding Hexoskin and infrared cameras would reduce the simulator's failure-mode detection score to 4 and its risk-priority number from 144 to 72. This was a modeled safety-analysis result rather than a prospective validation of Hexoskin with firefighter trainees.
HexoskinArticleOccupational Health & Human FactorsValidation & Methodology
Burr, L., Šula, J., Mayrhauser, J., & Meschtscherjakov, A. (2023). BREATHTURES: A first step towards breathing gestures as distinct input modality. In Extended Abstracts of the 2023 CHI Conference on Human Factors in Computing Systems (Article 60, pp. 1–6). ACM. https://doi.org/10.1145/3544549.3585787
SummaryUsing Hexoskin thoracic and abdominal respiratory movement, this preliminary study developed five breathing gestures as inputs for a game-like Android application. Seven users tested the gestures and rated the experience an average 9 out of 10. The study identified the need for more personalized detection and calibration to accommodate individual breathing patterns.
Key FindingOf five interface gestures based on Hexoskin chest and abdominal movement, breath holding and thoracic sighing received the highest ease ratings. In a separate 'worked well' question, five of seven participants selected hold breath and five selected deep thoracic breath. Several gestures required more than one detection attempt, and participants reported difficulty distinguishing thoracic from abdominal breathing; the authors identified blurred gesture distinctions and repeated attempts as reasons for further refinement and personalized calibration; these were future work, not demonstrated improvements.
Alizadeh, M., Shaker, G., De Almeida, J. C. M., Morita, P. P., & Safavi-Naeini, S. (2019). Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar. IEEE Access, 7, 54958-54968. https://doi.org/10.1109/ACCESS.2019.2912956
SummaryAlizadeh and colleagues used a 77 GHz frequency-modulated continuous-wave radar in a bedroom setting to estimate breathing and heart rates from a person lying on a bed. Hexoskin served as the wearable reference sensor for both measures. Radar estimates correlated 94% with Hexoskin breathing rate and 80% with Hexoskin heart rate under the reported conditions, so these results evaluate the radar rather than establish a new Hexoskin accuracy estimate.
Key FindingNon-contact radar estimates correlated 94% with Hexoskin breathing rate and 80% with Hexoskin heart rate. Hexoskin functioned as the wearable reference sensor, so the reported correlations evaluate the radar estimates rather than establish a new Hexoskin accuracy estimate.
Raw signals
Respiration
Data channels
Breathing RateHeart Rate
HexoskinAcademic ThesisOccupational Health & Human Factors
SummaryThis study examined how intolerance of uncertainty and task appraisal relate to stress and performance in RCMP law-enforcement students. Participants completed questionnaires and simulated emergency-driving and use-of-force tasks. Hexoskin recorded heart rate as a measure of physiological arousal.
Key FindingAmong RCMP law-enforcement students, greater intolerance of uncertainty was associated with lower combined driving performance in the second session. Intolerance of uncertainty was also positively associated with task appraisal, while subjective stress was not significantly associated with the reported performance scores or maximum heart rate. These are correlational findings and do not show that either construct caused changes in stress or performance; the paper's abstract gives a broader null conclusion that conflicts with the detailed driving result, so the mixed findings should be interpreted cautiously.
Alizadeh, M., Shaker, G., & Safavi-Naeini, S. (2020). Remote Health Monitoring System for Bedbound Patients. In 2020 IEEE 20th International Conference on Bioinformatics and Bioengineering (BIBE) (pp. 801-806). IEEE. https://doi.org/10.1109/BIBE50027.2020.00136
SummaryAlizadeh and colleagues developed a contactless MIMO-radar system to monitor breathing and sleep position for two adjacent bedbound subjects at a time. The study reports three experimental rounds with two subjects per round, but it does not state that these were six distinct people. Hexoskin served as the breathing-rate reference. The radar reached 97% overall breathing-rate accuracy, a maximum RMSE of 1.7 breaths/min and more than 83% correct sleep-position detection under the reported conditions.
Key FindingUsing Hexoskin as the breathing-rate reference, the contactless radar achieved 97% overall breathing-rate accuracy and a maximum RMSE of 1.7 bpm across the reported measurements. Sleep position was classified correctly in more than 83% of cases, supporting simultaneous breath and position monitoring of two nearby sleepers under the tested conditions.
Raw signals
Respiration
Data channels
Breathing Rate
HexoskinArticleData Science & Artificial IntelligenceOccupational Health & Human Factors
Calbert, L., & Hashemi Tonekaboni, N. (2024). Temporal dynamics of classroom stress: Insights from wearable sensors and machine learning. In 2024 International Conference on Machine Learning and Applications (ICMLA) (pp. 377–384). IEEE. https://doi.org/10.1109/ICMLA61862.2024.00057
SummaryResearchers used Hexoskin vests and Actigraph watches to collect physiological and movement data for classifying self-reported classroom stress in five undergraduates. They compared several machine-learning approaches, including models that preserved the timing of observations. A temporal random-forest analysis with a 30-day sliding training window reported about 92% median accuracy and F1, but performance was weaker when person-specific models were tested on a later semester. The small, demographically narrow sample limits generalization.
Key FindingIn five undergraduates monitored with Hexoskin vests and Actigraph watches, a temporal random-forest model using a 30-day sliding training window reached about 92% median accuracy and F1. That result came from temporal cross-validation; person-specific models performed poorly when trained on one semester and evaluated on a later semester. The study did not establish performance in larger or more diverse groups; stress labels were self-reported, sensor coverage was limited, and factors such as sleep, caffeine and outside stress were not controlled.
Alkurdi, A., He, M., Cerna, J., Clore, J., Sowers, R., Hsiao-Wecksler, E. T., & Hernandez, M. E. (2025). Extending Anxiety Detection from Multimodal Wearables in Controlled Conditions to Real-World Environments. Sensors, 25(4), 1241. https://doi.org/10.3390/s25041241
SummaryThis study evaluated whether machine-learning models developed with wearable data from controlled conditions could extend to real-world anxiety detection in young adults. Hexoskin contributed ECG, respiration, and 3-axis acceleration data within a multimodal system that also used an E4 wristband. XGBoost and Decision Tree performed strongly when models were trained and tested on the same subsets, whereas Random Forest led transfer learning in calibration and in-lab settings and SVM led for in-the-wild data. The findings show that environmental noise, multimodal signal contributions, and the balance of feature importance affect model robustness and transferability.
Key FindingWith multimodal inputs including Hexoskin ECG, respiration and acceleration, XGBoost reached 0.95 accuracy and 0.94 F1 score on the combined calibration subset and 0.92 accuracy and 0.90 F1 score on WEAR in-lab data. In transfer learning, Random Forest performed best for calibration and in-lab data, while SVM led for in-the-wild data, so the baseline leaders did not consistently retain their advantage. The RADWear in-the-wild data were 80% not anxious, and the researchers undersampled that majority class while preserving the minority observations.
Raw signals
AccelerationECGRespiration
HexoskinAcademic ThesisExercise Physiology & Sports ScienceOccupational Health & Human FactorsValidation & Methodology
SummaryThis thesis combined a health survey, field monitoring, a fitness substudy and laboratory validation to examine paramedic health and work demands. In the field study, Hexoskin recorded heart rate, respiratory rate, physical activity, energy expenditure and steps during 232 shifts completed by 32 paramedics. A separate laboratory study compared Hexoskin heart-rate and respiratory-rate measurements with standard measurements during cycling. Participant counts and results belong to distinct study components and should not be combined.
Key FindingDuring 232 monitored shifts, the 32-paramedic field cohort spent more time on calls per shift in metropolitan postings than in regional postings. In a separate 14-paramedic fitness substudy, greater estimated aerobic fitness was associated with lower heart rate at shift start and across shifts. These observational results do not establish causation, and the fitness subgroup was self-selected; a cardiac-arrest analysis was limited to four paramedics and seven arrests.
SummaryThis thesis evaluated how human-activity-recognition models performed when wearable hardware or recording sessions changed, using Astroskin and Zephyr BioHarness accelerometer data collected from the author as the sole participant in a home setting after COVID-19 restrictions prevented the planned research. An Astroskin-trained model dropped from 99.07% accuracy on Astroskin data to 65.74% on BioHarness data, while another model declined from 99.57% to 50.95% when tested in a different Astroskin recording session. A separate out-of-domain discriminator identified data from unfamiliar hardware or recording sessions with 97.60% accuracy. The thesis proposes this discriminator as a warning when incoming sensor data no longer match a model’s training conditions, but the one-person home experiment does not establish broader performance.
Key FindingActivity-recognition accuracy declined when wearable hardware or recording sessions changed: Model A fell from 99.07% on Astroskin data to 65.74% on BioHarness data, while Model A Type 1 fell from 99.57% to 50.95% across Astroskin sessions. The BioHarness-trained Model H achieved 29.63% on Astroskin data, but the thesis gives conflicting values for its same-domain BioHarness result; when both hardware and session differed from training, accuracy reached 19.28%. The out-of-domain discriminator flagged unfamiliar device or session data with 97.60% accuracy, but the experiment used only the author as a participant in a home setting after COVID-19 restrictions prevented the planned research, so broader performance remains unestablished.
Raw signals
Acceleration
Data channels
Activity
HexoskinArticleClinical Medicine & SurgeryNeuroscience, Sleep & Cognition
Campbell, K., Neul, J. L., Lieberman, D. N., Berry‑Kravis, E., Benke, T. A., Fu, C., Percy, A., Suter, B., Morris, D., Carpenter, R. L., Marsh, E. D., & von Hehn, J. (2025). A randomized, placebo‑controlled, cross‑over trial of ketamine in Rett syndrome. Journal of Neurodevelopmental Disorders, 17, Article 4. https://doi.org/10.1186/s11689-025-09591-y
SummaryA randomized, double-blind crossover trial enrolled 23 girls aged 6–12 years with Rett syndrome. Participants received five days of oral ketamine or placebo, followed by a nine-day washout and the alternate treatment; the studied doses were 0.75 or 1.5 mg/kg per dose, given twice daily. Hexoskin contributed daily activity, sleep, heart and lung-function data as exploratory measures. The primary outcome was safety and tolerability.
Key FindingIn a crossover trial that used Hexoskin for exploratory monitoring, five days of low-dose oral ketamine did not improve clinical outcomes over placebo in girls with Rett syndrome, although exploratory EEG findings showed first-dose target engagement. Most related adverse events were mild or moderate; one participant stopped treatment after Grade 3 vomiting; only 10 participants contributed to the EEG analysis, and no correction was applied for multiple comparisons. The trial tested only the two lowest planned doses and stopped after two cohorts because of recruitment difficulties, limiting conclusions about higher doses or longer treatment.
Amelard, R., Hedge, E. T., & Hughson, R. L. (2021). Temporal convolutional networks predict dynamic oxygen uptake response from wearable sensors across exercise intensities. NPJ Digital Medicine, 4(1), 156. https://doi.org/10.1038/s41746-021-00531-3
SummaryAmelard and colleagues used Hexoskin smart-shirt cardiorespiratory signals and reference oxygen-uptake measurements from a metabolic system in 22 healthy young adults completing cycle-ergometer protocols. A temporal convolutional network modeled dynamic oxygen uptake across exercise intensities. The predicted oxygen uptake classified light, moderate and vigorous activity second by second with 94.1% accuracy across 16,090 seconds. The authors describe the approach as a path toward quantitative aerobic-activity monitoring outside the laboratory when combined with tidal-volume and heart-rate-reserve calibration.
Key FindingAcross cycling intensities, a temporal convolutional network using 218 seconds of Hexoskin cardiorespiratory data produced a combined oxygen-uptake error of −22 ± 122 ml min−1. The temporal models had lower limits of agreement and substantially fewer parameters than the stacked LSTM comparison, while a heart-rate-only configuration showed high bias and variance. Predicted oxygen uptake classified light, moderate and vigorous activity with 94.1% accuracy across 16,090 seconds.
Carlson, L. A., Lawrence, M. A., & Kenefick, R. W. (2018). Hydration status and thermoregulatory responses in drivers during competitive racing. Journal of Strength and Conditioning Research, 32(7), 2061–2065. https://doi.org/10.1519/jsc.0000000000002268
SummaryNine male stock-car drivers were monitored during a competitive NASCAR event in hot conditions. Hexoskin continuously recorded heart rate during the racing session, while separate instruments measured core and skin temperature and environmental conditions. The study described hydration and physiological strain during a short race; it did not test whether these changes affected driving performance.
Key FindingDuring a roughly 17-minute race in which Hexoskin tracked heart rate and separate instruments measured temperature, nine male stock-car drivers lost 0.77 ± 0.3% of body weight on average and had a mean sweat rate of 0.63 ± 0.4 L/h. Core and skin temperatures rose, while the core-to-skin temperature gradient narrowed. The sweat-rate calculation included prerace activity, and the study did not measure the three- to four-hour fluid losses discussed as projections or test effects on driving performance.
SummaryCôté-Bélisle explored Hexoskin-supported biofeedback for emotional regulation and emotional awareness in young men with ADHD. Participants used heart-rate and breathing-rate reports to identify physiological-arousal surges and connect them with everyday emotional experiences. Both completers later reported greater competence in identifying, understanding, and managing their emotions.
Key FindingTwo young adults with ADHD completed the seven-week Hexoskin-supported biofeedback intervention. Both showed improved emotional regulation after the intervention and at the two-week follow-up, while emotional-awareness results varied by participant and instrument, with EDRE scores returning to baseline at follow-up. With two completers and no control group, the findings are preliminary and cannot establish that biofeedback caused the observed changes.
Data channels
Breathing RateHeart Rate
HexoskinArticleData Science & Artificial IntelligenceOccupational Health & Human FactorsValidation & Methodology
Caroll, T., Hernandez, G., Koutitas, G., Wierschem, D., Mendez, F., Vallez, D., Aslan, S., Koldenhoven, R., & Jimenez, J. (2020). Comparison of inverse kinematics algorithms for digital twin industry 4.0 applications. In 2020 IEEE International Conference on Systems, Man, and Cybernetics (SMC) (pp. 3319–3326). IEEE. https://doi.org/10.1109/smc42975.2020.9283253
SummaryThis prototype compared two inverse-kinematics algorithms for augmented-reality digital twins of manual-handling tasks. Motion-capture joint positions served as the reference for avatar-joint error. Participants also wore a Hexoskin Shirt and Smart Device to supply heart rate, breathing rate and calorie data for the broader fatigue-analysis setup, but the study did not report a biometric or fatigue-detection validation.
Key FindingIn the tested digital-twin setup, Bio IK used 38 body points and produced lower avatar-joint position error than Unity IK using nine points. Bio IK required more processor time but slightly less memory, and the authors integrated it into an augmented-reality application. The comparison concerns avatar positions measured against motion capture; it does not validate Hexoskin biometrics or establish that one algorithm performs better for every movement or system.
AstroskinPaperNeuroscience, Sleep & CognitionOccupational Health & Human FactorsClinical Medicine & Surgery
Innovative Biomonitoring Systems in the Aerospace Industry
Andreev, E., Radeva, V., & Nikolova, M. (2019). Innovative biomonitoring systems in the aerospace industry. N. Y. Vaptsarov Naval Academy, Varna, Bulgaria.
SummaryThis paper reviews physiological monitoring aboard the International Space Station and describes Astroskin in the context of a student proposal for a space medical center. The proposed center would link crew monitoring with physician support.
Key FindingAstroskin is discussed as a potential source of physiological data. The paper reports a design proposal, with no new wearer measurements or clinical outcome.
AstroskinPaperData Science & Artificial IntelligenceOccupational Health & Human Factors
McGregor, C. (2021). A platform for real-time space health analytics as a service utilizing space data relays. In 2021 IEEE Aerospace Conference (50100) (pp. 1–14). IEEE. https://doi.org/10.1109/AERO50100.2021.9438475
SummaryThis engineering paper proposes a way to combine Bio-Monitor recordings with other astronaut health data and transmit them through space data relays. It describes how the service could support monitoring beyond low Earth orbit.
Key FindingThe proposed service would move beyond downloading data after wear. The paper describes a system design; it reports no test of real-time Bio-Monitor transmission or astronaut health outcomes.
HexoskinAcademic ThesisNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Merrill, A. M. (2018). A transdiagnostic investigation of amygdala-vmPFC resting state functional connectivity and emotional distress in daily lives [Doctoral dissertation, University of Missouri-Columbia]. https://doi.org/10.32469/10355/66774
SummaryThis dissertation examined associations between resting-state amygdala–ventromedial prefrontal cortex connectivity and emotional distress in daily life using functional MRI and 14 days of ecological momentary assessment. Thirty-two women completed the procedures; three left-handed participants were excluded from all analyses, leaving 29 right-handed women, and two participants with low random-prompt compliance were further excluded from momentary analyses, leaving 27. Right amygdala–ventromedial prefrontal cortex connectivity was associated with sadness instability and a behavioral-dysregulation composite, while overall mean negative affect and overall affective instability were not significantly associated with connectivity. Participants wore Hexoskin while awake to collect cardiac activity, respiration and accelerometry, but the dissertation explicitly excluded all physiological data from its analyses and reports no Hexoskin physiological results.
Key FindingAmong the 27 participants retained for momentary analyses, resting-state connectivity between the amygdala and ventromedial prefrontal cortex was associated with specific outcomes. Right-sided connectivity was associated with sadness instability and the behavioral-dysregulation composite, while binge eating was associated with connectivity on both sides; overall mean negative affect and overall affective instability showed no significant association. These are specific, non-causal fMRI and ecological-momentary-assessment associations: although participants wore Hexoskin during the 14-day awake data-collection period, the dissertation excluded its cardiac, respiratory and accelerometry data from analysis and reports no Hexoskin physiological results.
SummaryThis thesis developed data-driven models that estimate the full blood-pressure waveform from electrocardiogram and photoplethysmography signals and attach an uncertainty measure to each estimate. Astroskin supplied electrocardiogram and photoplethysmography signals for both study components and tri-axial acceleration for daily-activity monitoring. The daily-activity study used Portapres as the blood-pressure reference, while the cycling study used NOVA from Finapres Medical Systems; reference-device failures excluded six of 18 cycling participants, leaving 12 for analysis. The studies used distinct participant groups, so their results remain tied to their individual protocols.
Key FindingAcross five participants in a daily-activity analysis, complete blood-pressure waveform estimates had a mean absolute error of 6.18 ± 0.73 mmHg when walking data were included and 5.85 ± 0.73 mmHg when they were excluded. Separate exercise analyses found that nonlinear autoregressive models with external inputs (NARX) tracked large mean arterial pressure changes, but did not capture changes linked to peripheral resistance from ECG and forehead PPG alone.
Raw signals
AccelerationECGPPG
Data channels
Pulse Transit Time
AstroskinPaperCardiology & ArrhythmiaOccupational Health & Human FactorsClinical Medicine & SurgeryData Science & Artificial Intelligence
SummaryResearchers used Astroskin ECG data to test a method for generating synthetic signals that combine features of wearable recordings with patterns from clinical ECGs. The study compared the generated signals with those from a model trained on mean squared error alone.
Key FindingThe authors reported that generated signals were 3.6 times closer to the original asymptomatic wearable ECGs and 1.3 times closer to the symptomatic clinical ECGs than the baseline model’s outputs. This measured signal similarity; it did not test diagnosis in astronauts.
Chaari, M., Abid, M., Ouakrim, Y., Lahami, M., & Mezghani, N. (2020). A mobile application for physical activity recognition using acceleration data from wearable sensors for cardiac rehabilitation. In Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (pp. 625–632). SCITEPRESS. https://doi.org/10.5220/0009118706250632
SummaryThis study developed a mobile human-activity-recognition application using three-axis acceleration from a Hexoskin garment. The classifier was evaluated on data from 40 healthy volunteers who repeated 10 activities and achieved 95.4% overall accuracy with a support vector machine under leave-one-subject-out testing. Home cardiac rehabilitation was the intended application, but no rehabilitation patients or clinical outcomes were evaluated.
Key FindingThe support-vector-machine classifier reached 95.4% overall activity-classification accuracy under leave-one-subject-out testing. It used Hexoskin acceleration data from 40 healthy volunteers, not cardiac-rehabilitation patients. The application displayed recognized activities and included an archive of medical reports for doctors, but increased home-rehabilitation participation remained an aim rather than a demonstrated outcome.
SummarySaini evaluated machine-learning and deep-learning models for human-activity recognition using participant-labeled Hexoskin data. Models trained with Capture24 were tested on Hexoskin data for activities including walking and sleeping. The conclusion reports 98.4% accuracy for an LSTM configuration that did not require manual feature engineering to distinguish walking from sleeping. The thesis presents healthcare use as a future possibility rather than a demonstrated clinical benefit.
Key FindingThe Hexoskin evaluation set focused on sleep and walking annotations, and the classifiers were assessed with accuracy, recall, precision and F1 score. The LSTM without manual feature engineering produced the strongest balanced test result reported in the table: 98.4% accuracy, 97.5% recall, 93.4% precision and 95.4% F1 score. Several tree and boosting configurations showed train-test gaps consistent with overfitting, and the thesis does not establish effectiveness in healthcare settings.
Raw signals
Acceleration
HexoskinAcademic ThesisExercise Physiology & Sports ScienceOccupational Health & Human FactorsValidation & Methodology
Développement d’une veste de refroidissement individuelle adaptée au travail en mines profondes
Al Sayed, C. (2018). Développement d’une veste de refroidissement individuelle adaptée au travail en mines profondes [Thèse de doctorat, École de technologie supérieure, Université du Québec].
SummaryThis thesis contains two separate human studies. A 42-minute cooling-garment test involved 19 male completers and evaluated a liquid-carbon-dioxide system in a hot, humid chamber. A second study compared Hexoskin and Polar H7 heart-rate measurements in 12 male volunteers during a 28-minute cycling protocol under moderate and hot, humid conditions. Cooling outcomes came from separate Polar H10 and thermometer measurements.
Key FindingIn the cooling study, which used Polar H10 for heart rate, wearing the garment was associated with lower internal body temperature and heart rate, lower perceived exertion and better comfort, humidity sensation and well-being during the 42-minute test. In the separate validation, average Hexoskin–Polar heart-rate correlations were 0.9987 in moderate conditions and 0.9985 in hot, humid conditions. These correlations do not establish individual interchangeability, and no miner field deployment was tested.
Apparicio, P., Gelb, J., Jarry, V., & Lesage-Mann, É. (2021). Cycling in one of the most polluted cities in the world: Exposure to noise and air pollution and potential adverse health impacts in Delhi. International Journal of Health Geographics, 20(1), 18. https://doi.org/10.1186/s12942-021-00272-2
SummaryApparicio and colleagues monitored three healthy male cyclists over five dry days in Delhi while modeling road-level noise and nitrogen-dioxide exposure. Hexoskin measured heart rate, breathing rate and minute ventilation; minute ventilation was combined with Aeroqual nitrogen-dioxide concentration to estimate inhaled dose. For one hour of cycling under moderate predicted pollution, estimated noise dose was 212% on residential streets and 459% on primary roads, while estimated inhaled nitrogen dioxide was 403 µg and 482 µg, respectively.
Key FindingIn Delhi, researchers combined Hexoskin ventilation data with environmental measurements. Cycling on a primary road rather than a residential street was associated with 47 µg/m³ more NO2 and 3.3 dB(A) more noise. After one hour in areas with moderate predicted pollution, estimated noise dose reached 212% on residential streets and 459% on primary roads, while inhaled NO2 reached 403 µg and 482 µg, respectively.
Data channels
Minute Ventilation
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human FactorsValidation & Methodology
Chang, T. P., Beshay, Y., Hollinger, T., & Sherman, J. M. (2019). Comparisons of stress physiology of providers in real-life resuscitations and virtual reality–simulated resuscitations. Simulation in Healthcare, 14(2), 104–112. https://doi.org/10.1097/SIH.0000000000000356
SummaryA single-site pilot compared physiological stress in 16 pediatric emergency physicians during real emergency-department resuscitations and a one-hour virtual-reality session. Across 69 monitored shifts and 31 resuscitations, heart-rate and salivary-cortisol increases were larger in real events, while perceived workload was higher in virtual reality. Hexoskin measured heart rate; cortisol and workload were separate measures.
Key FindingHeart rate measured with Hexoskin and cortisol measured in saliva rose more during real emergency-department resuscitations than during virtual simulations. Virtual-reality scenarios still increased heart rate, but the study did not establish equivalent physiological stress. This was a small, single-site provider study: nine shifts had entirely missing heart-rate data, and resuscitation type and patient outcomes were not collected; the real and virtual phases occurred in different settings and periods, so the comparison does not isolate simulation format alone.
Raw signals
ECG
Data channels
Heart Rate
HexoskinAcademic ThesisRespiratory & Infectious DiseaseExercise Physiology & Sports ScienceClinical Medicine & Surgery
Pelgröm, A. (2021). Breathing patterns of asthma patients during cycling ergometry [Master's thesis, University of Twente]. UT Student Theses. https://essay.utwente.nl/89148/
SummaryPelgröm used Hexoskin thoracic and abdominal respiratory-inductance signals to compare breathing coordination during maximal cycling in 12 people with asthma and 15 healthy controls. The study introduced BPratio, describing the balance between tidal volume and breathing frequency, and Ldis, a measure of thoraco-abdominal asynchrony. Most participants increased breathing depth before breathing frequency, while 33% of the asthma group accelerated breathing earlier in the workload. Deviant Ldis patterns were more common in asthma and were associated with reduced performance or greater post-exercise dyspnoea.
Key FindingMost participants increased tidal volume before accelerating breathing frequency late in exercise, but one third of the asthma group increased breathing frequency earlier, at about 30% to 40% of maximum workload. Both markedly increasing and unusually stable thoraco-abdominal asynchrony were associated with signs of dysfunctional breathing. These deviant patterns occurred in 33% of participants with asthma and 7% of healthy controls.
Raw signals
Respiration
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human Factors
Chang, T. P., Azen, C., & Sherman, J. M. (2020). Physiological stress markers following resuscitations remain elevated throughout physician shift hours. Academic Emergency Medicine, 27(6), 510–513. https://doi.org/10.1111/acem.13982
SummaryThis planned secondary analysis followed 21 pediatric emergency-medicine providers over 91 eight-hour shifts. Hexoskin recorded heart rate under work clothes, while salivary cortisol was sampled separately at scheduled points. Shifts with a preceding event had higher heart rate and cortisol at midshift and end-shift than shifts without an event.
Key FindingHeart rate measured with Hexoskin was higher at midshift and end-shift when a preceding event had occurred. Cortisol also remained higher at those points, rather than showing the decline seen on shifts without an event. Heart rate and cortisol were summarized at defined time points; the observational analysis did not establish how long changes lasted after shifts, cumulative health effects or patient outcomes.
Cherif, N., Ouakrim, Y., Benazza-Benyahia, A., & Mezghani, N. (2018). Physical activity classification using a smart textile. In 2018 IEEE Life Sciences Conference (LSC) (pp. 175–178). IEEE. https://doi.org/10.1109/LSC.2018.8572280
SummaryThirteen healthy volunteers each repeated 10 physical activities five times while wearing a Hexoskin garment with a waist-level accelerometer. The study classified these activities plus an unknown transition class using k-nearest-neighbor and support-vector-machine models. Overall test accuracy was 96.37% for the k-nearest-neighbor model and 95.4% for the support-vector-machine model under a random sample-level split.
Key FindingUsing waist acceleration from Hexoskin shirts worn by 13 healthy volunteers, a k-nearest-neighbor model classified activities with 96.37% accuracy. The researchers split samples at random, so the result does not show how well the model would classify the movements of a new participant.
Raw signals
Acceleration
HexoskinArticleRespiratory & Infectious DiseaseNeuroscience, Sleep & CognitionExercise Physiology & Sports ScienceClinical Medicine & Surgery
Aucoin, R., Nguyen, D., Ross, B., Bourbeau, J., Lewthwaite, H., Ekström, M., von Leupoldt, A., & Jensen, D. (2026). Effect of fan-to-face therapy on exertional breathlessness in adults with chronic lung disease. ERJ Open Research, 12(4). https://doi.org/10.1183/23120541.01636-2025
SummaryThirty-two adults with COPD or interstitial lung disease completed randomized four-minute treadmill tests with fan-to-face, fan-to-leg and no-fan conditions. Two participants could not wear the Hexoskin shirt and three more had unusable software data, leaving usable Hexoskin physiological data for 27 participants. Fan-to-face reduced breathlessness by 0.5 Borg units versus no fan but did not outperform fan-to-leg; ventilation, breathing pattern, heart rate and blood oxygen saturation did not differ across conditions. Clinically meaningful reductions of at least one Borg unit occurred in 31% of the full sample and 45% of the more-breathless exploratory subgroup under fan-to-face versus no fan.
Key FindingAcross all 32 participants, fan-to-face reduced breathlessness by 0.5 Borg units versus no fan but not versus fan-to-leg; the exploratory subgroup with at least moderate breathlessness improved by 0.9 units versus no fan. Usable Hexoskin physiological data were available for 27 participants, and ventilation, breathing pattern, heart rate and blood oxygen saturation did not differ across conditions.
Cherif, N. H., Mezghani, N., Gaudreault, N., Ouakrim, Y., Mouzoune, I., & Boulay, P. (2018). Physiological data validation of the Hexoskin smart textile. In Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) (Vol. 1, pp. 150–156). SCITEPRESS. https://doi.org/10.5220/0006588001500156
SummaryThe study compared Hexoskin heart rate, breathing rate and estimated ventilation with simultaneous laboratory references during a progressive maximal-exercise test. Results were reported for 28 healthy participants. Heart-rate and breathing-rate measurements generally showed high agreement, while estimated-ventilation results varied too widely for a firm validity conclusion.
Key FindingReported agreement coefficients for Hexoskin heart rate versus the laboratory reference were 0.98–0.99 for almost all participants, but one participant had much lower values of 0.58 and 0.59 after sensor-contact problems. Breathing-rate coefficients ranged from 0.91 to 0.99, whereas estimated-ventilation coefficients ranged from 0.2 to 0.99 and remained difficult to validate. The healthy laboratory sample and progressive exercise protocol do not establish performance in clinical or daily-living settings.
Raw signals
Respiration
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinArticleOccupational Health & Human Factors
Cheriyan, D., Khamraev, K., & Choi, J.-H. (2021). Varying health risks of respirable and fine particles from construction works. Sustainable Cities and Society, 72, Article 103016. https://doi.org/10.1016/j.scs.2021.103016
SummaryIn a controlled dust chamber, the study monitored particulate matter and inhalation rate across 15 construction activities and materials. Alphasense OPC-N3 sensors measured PM1, PM2.5 and PM10, while a Hexoskin wearable supplied inhalation-rate measurements. The authors used these measurements in a hazard-index model; the results do not represent disease incidence or demonstrate risk reduction at real construction sites.
Key FindingThe exposure model, which combined particle measurements with Hexoskin inhalation rate, calculated the highest particle-size hazard levels for M20 and M25 concrete mixing, even though the highest particulate-matter emissions occurred during concrete-block cutting. Mixing also had higher inhalation rates than the other activities. These are modeled hazard indices from controlled dust-chamber tests, not observed disease rates or evidence that a control reduced exposure; field validation at construction sites remains needed.
Auger, D., Almond, A., Wright, R., Breuer, J., Fletcher, F., & Jones, K. E. (2025). Bridging Spirit and Science: Physiological and Spiritual Effects of Wîwîp’son Healing Swing Sessions. Research Square. https://doi.org/10.21203/rs.3.rs-8399311/v1
Raw signals
AccelerationECG
Data channels
RR Interval
HexoskinArticleOccupational Health & Human Factors
Choi, J.-H., Khamraev, K., & Cheriyan, D. (2022). Hybrid health risk assessment model using real-time particulate matter, biometrics, and benchmark device. Journal of Cleaner Production, 350, Article 131443. https://doi.org/10.1016/j.jclepro.2022.131443
SummaryIn controlled dust-chamber simulations, this study combined real-time inhalation-rate data with particulate-matter and toxic-substance measurements to model construction-activity health risks. Hexoskin measured inhalation rate, Alphasense OPC-N3 sensors measured particulate matter, and MiniVol sampling supported toxic-substance analysis. The resulting indices are modeled hazard estimates, not observed disease rates or evidence of reduced exposure.
Key FindingIn a drilling study that paired particle sensors with Hexoskin inhalation-rate measurements, particulate-matter concentration was highest for M25 concrete blocks at 4.151 mg/m³ and lowest for solid blocks at 1.685 mg/m³. The paper reported aggregate toxic-substance hazard indices above its stated threshold across activities, while particulate-matter indices remained below it. These modeled classifications do not establish disease risk, regulatory compliance or performance at construction sites.
Bıçakcı, H. S., Santopietro, M., & Guest, R. (2023). Activity-based electrocardiogram biometric verification using wearable devices. IET Biometrics, 12(1), 38-51. https://doi.org/10.1049/bme2.12105
SummaryResearchers tested whether recognizing a person’s activity from an ECG before verifying identity improved biometric performance. They analyzed two public datasets, including ECG recorded with a Hexoskin Hx1 in the Vollmer dataset. Classifying activity first generally improved verification compared with using the ECG directly; a Naïve Bayes verifier generally produced lower equal-error rates than a decision tree.
Key FindingIn a comparison that included Hexoskin ECG, identifying activity before checking identity improved biometric verification relative to direct verification. The result concerns the analysis method, not a clinical diagnosis.
Raw signals
ECG
HexoskinArticleData Science & Artificial IntelligenceOccupational Health & Human Factors
Chowdhury, T. A., Gratz-Kelly, S., Wagner, E., Motzki, P., & Lehser, M. (2024). Ensemble learning approach for advanced predictive modeling of biometric data and action states with smart sensing. IEEE Access, 12, 139998–140008. https://doi.org/10.1109/ACCESS.2024.3466528
SummaryThis study used a Hexoskin-derived dataset containing heart rate, breathing rate, minute ventilation, cadence and activity to build forecasting and action-state models. Random-forest and XGBoost models predicted heart and breathing rates up to 25 minutes ahead. A separate hardware prototype converted sustained predicted drops or spikes into haptic and sound alerts; the study did not demonstrate clinical or safety outcomes.
Key FindingThe stacked model for forecasting breathing rate from a Hexoskin dataset reported 8.1% on the study's SI error metric. One example trained on one minute of data and predicted the next four minutes. Support-vector-machine classification performed less well than other tested approaches; these results come from the study dataset and prototype and do not establish clinical accuracy, real-world hazard prevention or universal forecasting performance.
Bıçakcı Yeşilkaya, H. S., & Guest, R. (2025). Activity-aware electrocardiogram biometric verification utilising deep learning on wearable devices. EURASIP Journal on Information Security, 2025(1), Article 7. https://doi.org/10.1186/s13635-025-00193-8
SummaryThis study investigated activity-aware electrocardiogram biometric verification using deep learning on wearable devices. It used ECG-only models in a framework designed to work with different device types, including a Hexoskin smart shirt with textile sensors. Activity-aware verification generally outperformed direct verification, although performance varied widely across image representations, window lengths and model settings.
Key FindingScalogram images generally produced the lowest equal-error rates, while Mel-spectrograms produced the highest; Faros performed better with SGDM and Hexoskin with Adam. The best reported Hexoskin result was a 0.49% equal-error rate in the four-second scalogram standing condition, with 0.49% false acceptance and 0% false rejection across one, three and five genuine enrollment samples. Activity-aware verification generally outperformed direct verification, but performance varied widely across model settings.
Raw signals
ECG
HexoskinArticleData Science & Artificial IntelligenceOccupational Health & Human Factors
Chowdhury, T. A., Gratz-Kelly, S., Wagner, E., Motzki, P., & Lehser, M. (2026). A multimodal intelligent system for human digital twin simulation with continuous kinematic data tracking, biometric prognosis, and cognitive state feedback in industrial environments. Advanced Intelligent Discovery, Article e202500217. https://doi.org/10.1002/aidi.202500217
SummaryResearchers built a digital twin of an industrial assembly task using physiological measurements from a Hexoskin vest, camera images and movement data from instrumented gloves. The prototype used these inputs to model movement and fatigue signals and trigger feedback. The authors observed unrealistic changes in simulated biometrics and avatar movement, limiting what the simulation can establish about workers.
Key FindingIn a prototype simulation combining Hexoskin measurements with cameras and smart gloves, the system reported 85.4% accuracy for fatigue-signal detection. Reported errors for the capacitive heart-rate and breathing-rate estimates were 3.14 and 2.91, respectively; these were not accuracy measurements of the shirt. Unrealistic biometric changes and avatar motion limit the interpretation of the simulation.
Babakhani, S., Remy, D., & Roitberg, A. (2025). Deep Learning for Metabolic Rate Estimation from Biosignals: A Comparative Study of Architectures and Signal Selection. arXiv. https://doi.org/10.48550/arXiv.2511.09276
HexoskinArticleClinical Medicine & SurgeryValidation & Methodology
Claiborne, A., Williams, A., Jolly, C., Isler, C., Newton, E., May, L., & George, S. (2023). Methods for analyzing infant heart rate variability: A preliminary study. Birth Defects Research, 115(10), 998–1006. https://doi.org/10.1002/bdr2.2177
SummaryThis preliminary study compared infant heart-rate and heart-rate-variability measures derived from electrocardiogram and RR-interval files after 5–10-minute resting recordings at one month of age. Researchers used a Hexoskin Shirt Junior, custom conversion scripts and Kubios software. Results differed for one variability measure, and only heart rate and low-frequency power were significantly correlated between file types.
Key FindingRoot mean square of successive differences showed a significant fixed bias between Hexoskin electrocardiogram-derived and RR-interval files, although Bland–Altman plots assessed several heart-rate-variability measures. Only heart rate and low-frequency power were significantly correlated between procedures. A discussion passage contradicts the latter result for low-frequency power, so these preliminary findings require cautious interpretation and standardized processing.
Raw signals
ECG
Data channels
Heart RateRR Interval
Metrics
RMSSD
HexoskinArticleClinical Medicine & SurgeryData Science & Artificial Intelligence
Baig, M., Mirza, F., GholamHosseini, H., Gutierrez, J., & Ullah, E. (2018). Clinical Decision Support for Early Detection of Prediabetes and Type 2 Diabetes Mellitus Using Wearable Technology. Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2018, 4456-4459. https://doi.org/10.1109/EMBC.2018.8513343
SummaryBaig and colleagues combined Hexoskin cardiac, respiratory, and activity measurements with blood glucose, demographics, clinical rules, and a knowledge base in an adaptive neuro-fuzzy model for early detection of prediabetes and type 2 diabetes. The approach was evaluated longitudinally in two people using 7.25 hours of real-time data and reported 91% accuracy, 94% sensitivity, 90% specificity, and 91% agreement with clinical assessment. The results support further evaluation of individualized wearable monitoring, while the two-person test limits generalizability.
Key FindingUsing Hexoskin cardiac, respiratory, and activity inputs, the adaptive neuro-fuzzy model achieved 91% accuracy, 94% sensitivity, and 90% specificity for the reported prediabetes and type 2 diabetes detection task; Kappa testing reported 91% overall agreement with clinical assessment.
Coden, G., Greenwell, P., Niu, R., Fang, C., Talmo, C., & Smith, E. L. (2024). Energy expenditure of femoral broaching in direct anterior total hip replacements—Comparison between manual and automated techniques. The International Journal of Medical Robotics and Computer Assisted Surgery, 20(1), Article e2592. https://doi.org/10.1002/rcs.2592
SummaryA single surgeon performed 26 direct-anterior total hip replacements with manual femoral broaching and 20 with a battery-powered automated system. Hexoskin-derived surgeon energy expenditure, heart rate and minute ventilation were compared during broaching. The automated method was associated with shorter broaching time and lower measured physiological demand in this observational, single-surgeon comparison.
Key FindingFor one surgeon performing total hip replacements, automated broaching took 3.7 minutes on average versus 6.1 minutes with manual broaching. Hexoskin estimates of the surgeon’s energy expenditure averaged 16.0 versus 32.6 Calories, respectively.
Data channels
Heart RateMinute Ventilation
HexoskinArticleClinical Medicine & SurgeryData Science & Artificial Intelligence
Baig, M. M., GholamHosseini, H., Gutierrez, J., Ullah, E., & Lindén, M. (2021). Early Detection of Prediabetes and T2DM Using Wearable Sensors and Internet-of-Things-Based Monitoring Applications. Applied Clinical Informatics, 12(1), 1-9. https://doi.org/10.1055/s-0040-1719043
SummaryBaig and colleagues combined Hexoskin vital-sign and activity measurements with blood glucose, demographics, clinical guidelines, and a knowledge base in an adaptive neuro-fuzzy model for early detection of prediabetes and type 2 diabetes. The model was trained with data from 36 participants and tested longitudinally in two people. It reported 91% overall Kappa agreement and included a descriptive two-year follow-up.
Key FindingA model combining Hexoskin measurements with clinical and other inputs achieved 91% overall agreement with expert assessment for early prediabetes and type 2 diabetes detection. In the two-person follow-up, the participant using the wearable and mobile-health approach had average HbA1c of 64 mmol/mol versus 87.5 mmol/mol in the participant receiving traditional management, but this descriptive comparison does not establish causality.
Banerjee, T., Anantharam, P., Romine, W. L., Lawhorne, L., & Sheth, A. (2015). Banerjee, T., Anantharam, P., Romine, W. L., Lawhorne, L. W., & Sheth, A. (2015, July 27-30). Evaluating a Potential Commercial Tool for Healthcare Application for People with Dementia [Conference presentation]. International Conference on Health Informatics and Medical Systems, Las Vegas, NV, United States. https://corescholar.libraries.wright.edu/knoesis/1063
SummaryBanerjee and colleagues evaluated Hexoskin as a prospective unobtrusive monitoring platform for dementia care, first validating cadence in four healthy adults across rest, walking, running, and sprinting. Cadence changed in the expected order across the four activity states. This preliminary validation did not test people with dementia.
Key FindingHexoskin cadence increased in the expected order from rest to walking, running, and sprinting, with 95.5% of cadence variation explained by activity state. Breathing rate, minute ventilation, and accelerometer activity were significantly correlated with cadence, supporting their use for activity-pattern detection, whereas heart rate was the least consistent cadence correlate.
Couture, L., Passalacqua, M., Joblot, L., Magnani, F., Pellerin, R., & Léger, P.-M. (2024). Adaptive system to enhance operator engagement during smart manufacturing work. Sensors & Transducers, 265(2), 106–119. http://www.sensorsportal.com/p_3339.htm
SummaryThis study developed a logistic-regression model to estimate manufacturing-operator engagement from respiration and acceleration data collected with Hexoskin. Under leave-one-out cross-validation, the model reported 80.95% accuracy. The prototype displayed engagement on a continuous color gradient calibrated to the range observed in its training data.
Key FindingOperator engagement was higher in manual work than in the automated condition on the Utrecht Work Engagement Scale absorption subscore, 4.21 versus 3.32. The logistic-regression model using Hexoskin respiration and acceleration predicted engagement states with 80.95% accuracy under leave-one-out cross-validation. The feedback display is a prototype based on respiration and acceleration; the study does not establish improved engagement, productivity or safety.
Banerjee, T., Peterson, M., Oliver, Q., Froehle, A., & Lawhorne, L. (2018). Validating a Commercial Device for Continuous Activity Measurement in the Older Adult Population for Dementia Management. Smart Health, 5-6, 51-62. https://doi.org/10.1016/j.smhl.2017.11.001
SummaryBanerjee and colleagues evaluated Hexoskin against laboratory reference measures in 31 adults aged 65 years or older, including participants with mobility impairment, cognitive impairment, both, or neither. Processed cadence, respiration rate, and heart rate showed useful agreement with their references, while minute ventilation and short-duration activity level did not. The findings support selective longitudinal monitoring in older adults and emphasize signal-specific validation before dementia-management use.
Key FindingIn 31 older adults, processed Hexoskin cadence, respiration rate and heart rate tracked their corresponding reference measures, while minute ventilation and short-duration activity level did not. Heart rate and processed cadence showed the strongest agreement, and respiration rate showed a moderate but significant association with low bias. The results support selective use of the validated signals and do not establish that every commercial-sensor output is clinically interchangeable with its reference.
Couture, L., Passalacqua, M., Joblot, L., Magnani, F., Pellerin, R., & Léger, P.-M. (2024). Enhancing operator engagement during AI-assisted manufacturing work using optimal state deviation feedback system. In Proceedings of the 4th IFSA Winter Conference on Automation, Robotics & Communications for Industry 4.0/5.0 (ARCI 2024) (pp. 232–237). https://sam.ensam.eu/handle/10985/24788
SummaryTwenty-two participants completed manual and fully automated snowshoe-assembly tasks while wearing Hexoskin for physiological data collection. Those data were used to build the Optimal State Deviation Index for estimating engagement. The model reported 80.95% test accuracy under leave-one-out cross-validation. A separate prototype displayed engagement through a color gradient as part of an iterative biocybernetic-feedback design.
Key FindingThe Optimal State Deviation Index, developed using Hexoskin data during manual and automated snowshoe assembly, achieved 81.31% accuracy on training data and 80.95% under leave-one-out testing. The formula used the full Task 1 and Task 2 dataset, so the test estimate comes from cross-validation rather than a separate external cohort. In display testing, participants found the discrete color gradient more distracting; the study did not demonstrate improved workplace performance or safety.
Barker, L., & Mercer, J. (2017). Measuring Acceleration of a Trampoline Circus Act During Training and In-Show Using Wearable Technology [Conference abstract]. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000519030.33160.bb
Raw signals
Acceleration
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human Factors
Cozzarelli, N. F., Ashkenazi, I., Khan, I. A., Lonner, J. H., Lajam, C., Schwarzkopf, R., & Rozell, J. C. (2024). Surgeons Experience Greater Physiologic Stress and Strain in the Direct Anterior Approach Than the Posterior Approach for Total Hip Arthroplasty. The Journal of Arthroplasty, 39(9 Suppl 2), S322–S326. https://doi.org/10.1016/j.arth.2024.05.063
SummaryFive high-volume surgeons were monitored with Hexoskin during 144 consecutive total hip arthroplasties: 67 direct-anterior and 77 posterior procedures. Direct-anterior cases were shorter but were associated with higher surgeon stress index, heart rate and minute ventilation. This observational comparison concerns surgeon physiology and does not establish patient outcomes or that surgical approach caused the differences.
Key FindingIn five surgeons monitored with Hexoskin, direct-anterior procedures had a mean stress index of 17.4 versus 12.4 for posterior procedures. Heart rate averaged 101 versus 98.3 beats/min, and minute ventilation 21.7 versus 18.7 L/min. Operative time was shorter for the direct-anterior approach; results came from five high-volume surgeons and may not generalize to other surgeons, settings or patient outcomes.
Data channels
Breathing RateHeart RateMinute Ventilation
Metrics
RMSSD
HexoskinArticleExercise Physiology & Sports ScienceOccupational Health & Human Factors
Barker, L., Burnstein, B., & Mercer, J. (2020). Acceleration profile of an acrobatic act during training and shows using wearable technology. Sports Biomechanics, 19(2), 201-211. https://doi.org/10.1080/14763141.2018.1460394
SummaryBarker and colleagues used Hexoskin's hip-mounted tri-axial accelerometer to compare seven male acrobats' trampoline performances across training and shows. Training produced higher average, RMS, and RM4 acceleration, whereas perceived exertion was higher during shows and time in defined acceleration ranges did not differ significantly. The study positions wearable inertial measurement as a practical workload-management tool for theatre and arena performances where GPS is inoperable.
Key FindingHexoskin accelerometry showed higher average, RMS, and RM4 acceleration during training than shows, while artists rated shows as more exerting and time within the five acceleration ranges did not differ significantly. These track-level profiles suggest wearable inertial data can help coaches characterize mechanical demands in theatre environments where GPS is unavailable.
D’Souza, A. W., Notley, S. R., Brown, E. K., Poirier, M. P., & Kenny, G. P. (2019). The Hexoskin physiological monitoring shirt does not impair whole-body heat loss during exercise in hot-dry conditions. Applied Physiology, Nutrition, and Metabolism, 44(3), 332–335. https://doi.org/10.1139/apnm-2018-0370
SummaryNine healthy young men completed four randomly ordered exercise sessions in hot, dry conditions. Each session included seated rest, 60 minutes of semi-recumbent cycling at a fixed metabolic heat production and 60 minutes of recovery. Comparisons found no evidence that Hexoskin, worn alone or under a work uniform, impaired whole-body heat dissipation under the tested conditions.
Key FindingBody heat storage was similar with Hexoskin alone and the semi-nude control, 214 versus 211 kJ. Under a work uniform, storage was also similar with Hexoskin and a cotton undershirt, 307 versus 318 kJ. Evaporative, dry and total heat loss did not differ significantly between the paired conditions; this controlled study in nine men does not establish results for other populations, clothing systems or environments.
HexoskinConference AbstractOccupational Health & Human FactorsClinical Medicine & Surgery
Baylon, G., Soghier, L., Gordish, H., & Wolfe, A. (2025). A Pilot Study Measuring Pediatric Clinician Daily Physiologic Stress Using Heart Rate Variability [Conference abstract]. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0001099128.48142.cb
Raffoul, D. (2019). Validation and responsiveness of wearable biometric technology to monitor cardiac and ventilatory parameters at rest and during exercise in COPD [Master’s thesis, McGill University]. eScholarship@McGill. https://doi.org/10.82308/47051
SummaryThis master’s thesis compared Hexoskin with a Vmax metabolic cart during incremental and constant-workload cycling in adults with chronic obstructive pulmonary disease. Fourteen participants wore the shirt; seven contributed to the assessment of change after pulmonary rehabilitation. Heart rate and breathing rate changed with exercise, without significant device or device-by-time effects across the three tests. The findings for tidal volume and inspiratory capacity were less consistent.
Key FindingHexoskin and Vmax showed similar heart-rate and breathing-rate responses during exercise in the COPD cohort. The small rehabilitation subgroup and the less consistent lung-volume results limit conclusions about using the devices interchangeably.
Darnell, M. E., Quinn, T. D., Carnahan, S. P., Carpenter, T., Meglino, N., Yorio, P. L., & Doperak, J. M. (2022). Effect of cloth masks and N95 respirators on maximal exercise performance in collegiate athletes. International Journal of Environmental Research and Public Health, 19(13), 7586. https://doi.org/10.3390/ijerph19137586
SummaryTwelve Division I collegiate athletes completed graded treadmill tests while wearing an N95 respirator, a cloth mask or no face covering. Hexoskin continuously measured heart rate and breathing rate. Exercise lasted longer without a face covering; heart-rate slopes were similar across conditions, while breathing rate increased more steeply without a covering than with a cloth mask.
Key FindingHeart rate measured with Hexoskin increased similarly across the N95, cloth-mask and no-covering conditions, with no significant difference in slopes. Breathing rate rose in all conditions, but the increase was steeper without a covering than with a cloth mask. Transcutaneous carbon dioxide decreased over time only in the no-covering condition; results from 12 athletes and a maximal treadmill protocol do not establish effects in other populations or everyday activity.
Beltrame, T., Amelard, R., Wong, A., & Hughson, R. L. (2017). Extracting aerobic system dynamics during unsupervised activities of daily living using wearable sensor machine learning models. Journal of Applied Physiology, 124(2), 473-481. https://doi.org/10.1152/japplphysiol.00299.2017
SummaryBeltrame and colleagues monitored 13 healthy active men with Hexoskin for about six hours per day over four days to study aerobic-system dynamics during unsupervised daily activity. Hexoskin cardiac, respiratory and movement features were used to predict free-living oxygen uptake and derive aerobic-system dynamics. The predicted daily-life temporal measure correlated with the directly measured laboratory measure at r=0.82 (p<0.001).
Key FindingAerobic-system mean normalized gain derived from predicted oxygen uptake during unsupervised daily activity correlated with the laboratory-derived measure at r=0.82 (p<0.001; n=13), with a consistent difference of about 16%. The model distinguished light, moderate and vigorous activity, but only about 20% of monitored data occurred while participants were active enough for reliable aerobic-system analysis. Hexoskin supplied continuous activity, breathing and heart-rate inputs, while free-living oxygen uptake was model-predicted and the proposed health-status application remained speculative.
Raw signals
Acceleration
Data channels
Breathing RateCadenceHeart RateMinute Ventilation
HexoskinArticleOccupational Health & Human Factors
MacQuarrie, A., & Whitfield, S. (2019). Fit for duty: shedding light on paramedics’ health via research methodologies. International Paramedic Practice, 9(2), 47–49. https://doi.org/10.12968/ippr.2019.9.2.47
SummaryA field study monitored 32 paramedics with Hexoskin around work shifts and emergency calls, recording heart rate, respiratory rate and occupational acceleration. Fourteen also completed maximal cardiorespiratory fitness testing. The study examined how posting, body mass, call characteristics and fitness were associated with physiological responses during paramedic work.
Key FindingIn 32 paramedics monitored with Hexoskin, posting, body mass index and call type were associated with physiological responses during shifts and emergency calls. Greater cardiorespiratory fitness was associated with lower physiological demand among the 14 participants who completed fitness testing. These observational findings do not show that posting, body mass or fitness caused the measured differences.
Beltrame, T., Amelard, R., Wong, A., & Hughson, R. L. (2017). Prediction of oxygen uptake dynamics by machine learning analysis of wearable sensors during activities of daily living. Scientific Reports, 7, 45738. https://doi.org/10.1038/srep45738
SummaryBeltrame and colleagues evaluated oxygen-uptake prediction in 16 healthy active men during controlled random-paced walking and approximately 20 minutes of simulated daily activities. Hexoskin cardiac, respiratory, and motion features supplied the wearable inputs, while a COSMED K4b2 system provided the directly measured oxygen-uptake reference. The findings support prediction under the tested activity conditions and identify the need for further reliability testing before broader application.
Key FindingIn 16 healthy active men, the Hexoskin-feature random-forest model predicted oxygen uptake during simulated daily activities with r=0.87 versus COSMED measurements and produced mean normalized gain correlated at r=0.71 with the measured endpoint. The model distinguished resting, light, and moderate metabolic demands, but intense activity represented less than 2% of the data and was excluded from the validated range.
Raw signals
AccelerationECGRespiration
Data channels
Breathing RateCadenceHeart RateMinute Ventilation
HexoskinArticleOccupational Health & Human Factors
Davidson, J. M., Pulford-Thorpe, A., Callaghan, J. P., & Dominelli, P. B. (2025). An active sitting chair can increase energy expenditure while performing standardized data entry work. Work: A Journal of Prevention, Assessment and Rehabilitation, 81(1), 2129–2138. https://doi.org/10.1177/10519815241303339
SummarySixteen participants completed 20-minute standardized data-entry tasks in an active chair and a conventional chair. A metabolic cart measured oxygen uptake and ventilation, while Hexoskin measured heart rate and heart-rate variability. On average, active sitting increased oxygen uptake by 0.02 L/min and energy expenditure by 1.5 kcal per 15 minutes, with substantial individual variation.
Key FindingTen of 16 participants increased oxygen uptake in the active chair, two showed no change and four showed a decrease; the average change was 0.02 ± 0.04 L/min. Hexoskin cardiac measurements showed larger relative heart-rate-variability decreases in males than females, although absolute between-sex differences were not significant. This short laboratory study does not establish long-term health, productivity or weight-management benefits.
Beltrão, G., Alaee-Kerahroodi, M., Schroeder, U., Tatarinov, D., & Bhavani Shankar, M. R. (2022). Nonlinear Least Squares Estimation for Breathing Monitoring Using FMCW Radars. In 2021 18th European Radar Conference (EuRAD) (pp. 241-244). IEEE. https://doi.org/10.23919/EuRAD50154.2022.9784561
SummaryThis study used Hexoskin as a reference sensor to evaluate non-contact breathing-rate estimation with a frequency-modulated continuous-wave radar. A nonlinear least-squares estimator was compared with discrete Fourier transform and frequency-time phase-regression approaches in static, texting, and typing conditions. The proposed method produced high within-one-breath-per-minute accuracy in the laboratory tests.
Key FindingIn a 10-minute seated test, 94.5% of breathing-rate estimates from a 77 GHz radar and nonlinear least-squares model were within one breath per minute of the Hexoskin reference. Across the tested scenarios, the authors reported accurate estimation and improvement over discrete Fourier transform and frequency-time phase-regression methods, but the laboratory evidence does not establish performance in a broader population or free-living setting.
Raw signals
Respiration
Data channels
Breathing Rate
AstroskinPoster / PresentationOccupational Health & Human FactorsValidation & MethodologyExercise Physiology & Sports Science
DeLeon, R., Cowings, P., & Toscano, B. (2016, August 15). Wearable biosensor monitor to support autonomous crew health and performance [Poster presentation]. University of Houston-Clear Lake Student Symposia, Clear Lake, TX, United States. NASA Technical Reports Server. https://ntrs.nasa.gov/citations/20190000238
SummaryEight crew members wore an Astroskin prototype during two 30-day missions in NASA’s ground-based Human Exploration Research Analog. The team assessed wake and sleep recordings, exercise monitoring, and how easily crew could use the system.
Key FindingThe team obtained usable physiological data across 24-hour wake and sleep periods, and crew described the prototype as comfortable and easy to use. The study tested feasibility in a ground analog.
Bennett, S. L., Goubran, R., & Knoefel, F. (2016). Adaptive eulerian video magnification methods to extract heart rate from thermal video. In 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA) (pp. 1-5). IEEE. https://doi.org/10.1109/MeMeA.2016.7533818
SummaryBennett and colleagues evaluated whether thermal video could recover heart rate using adaptive Eulerian Video Magnification. A seated subject wore a Hexoskin smart shirt to provide the ECG reference while light and thermal cameras recorded simultaneously. Wide-band processing identified a chest region of interest, and narrow-band thermal processing produced an oscillation at 0.9 Hz, matching the ECG frequency of about 54 beats/min. The proof of concept supports further study of contactless physiological-signal extraction but does not establish validation across people or conditions.
Key FindingThe narrow-band thermal signal and Hexoskin ECG both oscillated at 0.9 Hz, approximately 54 beats/min, and the authors reported a strong correlation. This was a seated single-subject proof of concept.
Mannée – Boele, D. (2022). Current and novel methods to measure dynamic hyperinflation in patients with COPD: Accuracy and usability in telemonitoring [Doctoral thesis, Radboud University Nijmegen]. Radboud Repository. https://repository.ubn.ru.nl/handle/2066/250220
SummaryThis doctoral thesis examined whether Hexoskin respiratory measurements were stable enough for monitoring changes in lung volume. Researchers used a torso simulator to test the shirts’ response to changes in temperature and circumference. A separate experiment compared shirt measurements with spirometry during seven everyday tasks in 15 healthy adults. The human experiment did not establish accuracy in patients with COPD.
Key FindingNine of 12 Hexoskin shirts showed a linear response to changes in torso circumference on the simulator. Temperature correction reduced median drift from −34.7 to −0.5 mL/°C, identifying a source of measurement error that can be tested independently of breathing changes.
Bennett, M., Čironis, L., Sousa, A., Ahmad, S. L., Hassan, T., Yuen, K., Douris, P., Zwibel, H., DiFrancisco-Donoghue, J., & Koshy, A. (2022). Continuous monitoring of HRV in esports players. International Journal of Esports, 2(2). https://www.ijesports.org/article/60/html
SummaryBennett and colleagues used Hexoskin to monitor ECG-derived beat intervals and heart-rate variability during 1.5- to 2.5-hour League of Legends and Overwatch sessions. The results describe 19 male players across two cohorts, while the limitations describe n=10 and two device failures, leaving an unresolved internal count discrepancy. Winning-team mean SDRR was lower, but substantial individual variability and missing high-resolution gameplay context prevented a confident link between heart-rate variability and performance.
Key FindingHexoskin HRV showed a moderate association with esports activity and a team-level correlation of r=0.78 between winning and losing teams' global HRV patterns. The winning team had lower mean SDRR, but substantial individual variability and absent high-resolution gameplay context prevented a confident link between HRV and performance.
Denning, M., Smith, M., Zagrodnik, J., & Ruden, T. (2016). Movement intensity and caloric expenditure differences between walking and pickleball [Abstract]. Medicine & Science in Sports & Exercise, 48(5 Suppl), 209. https://doi.org/10.1249/01.mss.0000485629.74799.e1
Raw signals
Acceleration
Data channels
CadenceEnergy Expenditure
HexoskinArticleCardiology & ArrhythmiaRespiratory & Infectious DiseaseNeuroscience, Sleep & CognitionOccupational Health & Human Factors
Betson, J., Fein, E. C., Long, D., & Horrocks, P. (2024). Quantifying Threat or Challenge Response of Undergraduate Paramedicine Students During High-Stress Clinical Scenarios: A Narrative Review. International Journal of Paramedicine, (8), 173-189. https://doi.org/10.56068/QHQM3379
SummaryBetson and colleagues narratively reviewed approaches for quantifying threat-or-challenge responses among undergraduate paramedicine students during high-stress clinical scenarios. The review is motivated by the mental, physical, and emotional demands of paramedicine practice. Within its survey of cardiovascular measurement options, the review identifies Hexoskin as a portable technology for monitoring cardiovascular responses.
Key FindingThe narrative review treats challenge and threat as physiologically distinguishable stress appraisals and surveys cardiovascular and hormonal measurements that could be combined in high-stress paramedicine scenarios. Hexoskin is presented as one portable cardiovascular-monitoring option, not as a device validated by a new trial in this paper.
Denning, W. M., Zagrodnik, J., Smith, M., & Ruden, T. (2022). Physical activity differences between walking and playing pickleball doubles. Science & Sports, 37, 513.e1-513.e4. https://doi.org/10.1016/j.scispo.2021.06.009
SummaryTwenty-five healthy adults completed 30-minute pickleball-doubles and self-paced walking sessions on the same day in counterbalanced order. Hexoskin provided heart rate, step count and movement-based caloric-expenditure estimates. Pickleball produced higher heart rate, estimated caloric expenditure, perceived exertion and enjoyment, while walking produced more steps.
Key FindingMean heart rate measured with Hexoskin was nearly 14% higher and peak heart rate nearly 19% higher during pickleball doubles than walking. Estimated caloric expenditure was 36% higher during pickleball, while walking produced 54% more steps. The calorie values were movement-based predictions rather than oxygen-consumption measurements, and results from 25 healthy adults do not establish long-term health or weight-management benefits.
Data channels
Energy ExpenditureHeart RateSteps
Metrics
Steps
HexoskinArticleCardiology & ArrhythmiaRespiratory & Infectious DiseaseNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Birdee, G., Nelson, K., Wallston, K., Nian, H., Diedrich, A., Paranjape, S., Abraham, R., & Gamboa, A. (2023). Slow breathing for reducing stress: The effect of extending exhale. Complementary Therapies in Medicine, 73, 102937. https://doi.org/10.1016/j.ctim.2023.102937
SummaryBirdee and colleagues conducted a 12-week randomized, single-blinded trial comparing extended-exhale and equal-ratio slow breathing. The abstract reports 100 participants, while the article body reports 99 enrolled, 97 in the intention-to-treat analysis and 94 with complete data. Participants wore Hexoskin shirts during home practice to assess adherence to the assigned breathing ratios. Slow breathing reduced PROMIS Anxiety within both groups, while neither strategy significantly changed heart-rate variability and the between-group differences were nonsignificant.
Key FindingTwelve weeks of slow breathing reduced psychological stress within both groups, but extending exhalation did not provide a significant incremental benefit over equal-ratio breathing. Neither intervention significantly changed high-frequency heart-rate variability, while Hexoskin confirmed adherence to the assigned home breathing patterns.
Data channels
Breathing Rate
HexoskinArticleOccupational Health & Human FactorsValidation & Methodology
Dhillon, P., Tam, K., & Juneau, E. (2022). Dress for success: Embedded health sensors in the future soldier. Journal of Military, Veteran and Family Health, 8(2), 109-115. https://doi.org/10.3138/jmvfh-2021-0095
SummaryOne Canadian military section commander wore Hexoskin during a reserve-unit field exercise in British Columbia. The report describes 30 hours of continuous recording and a Bluetooth field test during a simulated mass-casualty event. The wearer reported comfort, no interference with duties and no apparent equipment failure during the exercise.
Key FindingThe Hexoskin garment was reported as comfortable and did not impede the wearer’s field-training tasks; no apparent failure or breakdown was observed during the exercise. It was worn over bare skin beneath a cotton T-shirt, fatigue top, rain jacket and tactical load-bearing vest with blank ammunition, without body armour or ballistic plates. This single-person training report does not establish performance across personnel, protective configurations or operational deployments.
Bishnoi, A., & Hernandez, M. E. (2025). Heart rate reserve effects on brain activation and cognitive-motor performance while doing an instrumented trail walking task in middle-aged to older adults. Archives of Gerontology and Geriatrics Plus, 2, 100115. https://doi.org/10.1016/j.aggp.2024.100115
SummaryBishnoi and Hernandez examined how heart-rate reserve was associated with prefrontal-cortex activation and gait during increasingly difficult Trail Walking Tasks. Heart-rate reserve was calculated from baseline resting heart rate and a formula-based maximum, while Hexoskin recorded heart-rate responses during the walking tasks and fNIRS measured brain activation. Higher heart-rate reserve was associated with greater prefrontal activation and shorter stride time, while stride width and stride length showed no significant heart-rate-reserve or task effects.
Key FindingIn a walking study that used Hexoskin to track heart rate during the tasks, higher heart-rate reserve was associated with greater prefrontal-cortex activation and shorter stride time during the more difficult dual-task walking conditions. Greater HbO2 activation was also associated with higher MoCA and Mini-BEST scores and faster walking, but cognitive error-rate effects were not significant.
Bishop, A., MacNeil, E., & Izzetoglu, K. (2021). Cognitive Workload Quantified by Physiological Sensors in Realistic Immersive Settings. In D. D. Schmorrow & C. M. Fidopiastis (Eds.), Augmented Cognition (Lecture Notes in Computer Science, Vol. 12776, pp. 119-133). Springer. https://doi.org/10.1007/978-3-030-78114-9_9
SummaryNine law-enforcement trainees aged 21 to 31 completed one-screen and five-screen use-of-force simulator conditions. Multimodal sensors tracked cognitive-workload biomarkers, with Hexoskin supplying heart and respiratory rates. Under higher immersion, prefrontal oxygenation and heart rate increased, while respiratory rate decreased. The findings support feasibility in this preliminary setting but require confirmation in a larger sample.
Key FindingIn a study using Hexoskin for heart and respiratory rates and separate sensors for brain oxygenation, higher immersion was associated with increased oxygenation in three of four prefrontal-cortex regions and an increase in heart rate from 86.70 to 87.66 beats per minute. Respiratory rate decreased from 18.49 to 17.84 breaths per minute, a statistically significant but practically negligible change contrary to the hypothesis; bilateral Index of Cognitive Activity also changed in the opposite direction from expected. The two self-report scales showed no significant difference, and the nine-participant findings require further validation.
Ding, T. Y., Gagliano, L., Jahani, A., Toffa, D. H., Nguyen, D. K., & Bou Assi, E. (2024). Epileptic seizure forecasting with wearable-based nocturnal sleep features. Epilepsia Open, 9(5), 1793-1805. https://doi.org/10.1002/epi4.13008
SummaryThe study used Hexoskin nocturnal sleep features to forecast seizure days in 78 hospitalized people with epilepsy. Support-vector-machine models normalized features to reference nights and evaluated 16-hour and 24-hour horizons with nested leave-one-patient-out cross-validation. The authors reported improvement over chance for some patients and called for longer recordings in residential settings.
Key FindingIn 78 hospitalized people with epilepsy, forecasts using Hexoskin sleep measurements beat chance for approximately 49% of patients at 16 hours and 40% at 24 hours. These percentages are the shares of patients whose forecasts outperformed chance, not the proportions of seizures predicted.
Raw signals
AccelerationECGRespiration
Metrics
BR AvgHR AvgSleep EfficiencySleep Non REM TimeSleep Position ChangesSleep REM TimeTime to Fall AsleepTotal Sleep Time
HexoskinPoster / PresentationCardiology & ArrhythmiaRespiratory & Infectious DiseaseOccupational Health & Human Factors
Bläsing, D., & Schicha, M. (2017). Wirkung von Herzkohärenztraining auf Real-Life-Stressoren. In Gesellschaft für Arbeitswissenschaft e.V. (Ed.), Soziotechnische Gestaltung des digitalen Wandels - kreativ, innovativ, sinnhaft: 63. Kongress der Gesellschaft für Arbeitswissenschaft (Beitrag A.3.1). GfA-Press. https://gfa2017.gesellschaft-fuer-arbeitswissenschaft.de/inhalt/A.3.1.pdf
SummaryRunners used real-time Hexoskin breathing feedback during treadmill running through three visual displays: ambient Trees, directional Arrows and a continuous Path. Speeds were adjusted individually in a sport-science laboratory. Interviews, body maps and questionnaires described different ways participants perceived, adapted to and interacted with the breathing visualizations.
Key FindingSome participants reported a mismatch between their breathing and the Path triangle, while others deliberately varied their breathing to explore the Trees response. Arrow cues helped several runners understand inhale-and-exhale timing or find a more intuitive rhythm. These qualitative, self-reported experiences from a laboratory session do not establish improved breathing, running performance or training outcomes.
Raw signals
Respiration
Data channels
Breathing RateHeart Rate
HexoskinArticleCardiology & ArrhythmiaNeuroscience, Sleep & CognitionExercise Physiology & Sports ScienceOccupational Health & Human FactorsValidation & Methodology
Bläsing, D., Buder, A., Reiser, J. E., Nisser, M., Derlien, S., & Vollmer, M. (2022). ECG performance in simultaneous recordings of five wearable devices using a new morphological noise-to-signal index and Smith-Waterman-based RR interval comparisons. PLoS ONE, 17(10), e0274994. https://doi.org/10.1371/journal.pone.0274994
SummaryBläsing and colleagues simultaneously compared Hexoskin Hx1 with four other wearable ECG devices in 13 adults across four five-minute phases: rest, walking, cognitive workload and uphill walking. They assessed local ECG noise, QRS detection and RR-interval quality with morphSQ and a modified Smith-Waterman approach. Hexoskin achieved 91.33% sufficient morphological signal quality overall and a QRS positive predictive value of 0.989. Signal quality was highest at rest and during the standing two-back task and lower during level and uphill walking, showing that performance depended on the activity.
Key FindingHexoskin provided acceptable ECG performance overall, with 91.33% sufficient morphological signal quality and a QRS positive predictive value of 0.989. Sufficient signal quality was 99.61% at rest, 86.82% during level walking, 99.15% during the two-back task and 77.60% uphill. Movement produced more noise, and close shirt fit mattered because electrode displacement could reduce accuracy; Faros produced the most stable results in this simultaneous comparison.
Dixon, P. C., Dubeau, S., Roy, J.-F., & Fournier, P.-A. (2025). Automatic cough detection via a multi-sensor smart garment using machine learning. Computers in Biology and Medicine, 191, Article 110192. https://doi.org/10.1016/j.compbiomed.2025.110192
SummaryIn an observational study, 44 healthy adults wore a Hexoskin garment while performing prompted coughs and other respiratory tasks in supine and seated positions. A random-forest model using the garment’s acceleration and respiratory-inductance features reported an F1 score of 93.0 ± 1.1%, precision of 84.2 ± 4.2% and sensitivity of 95.5 ± 1.6%. Patient monitoring was proposed as future work.
Key FindingThe cough-detection model using Hexoskin acceleration and respiration reported an F1 score of 93.0 ± 1.1%, compared with 93.1 ± 1.3% when all sensors were used. Acceleration- and respiration-based models outperformed electrocardiogram-based models for this task. The study used prompted tasks in 44 healthy adults under stationary conditions; it did not establish performance during substantial movement or in patients with spontaneous cough.
Vollmer, M., Bläsing, D., Reiser, J. E., Nisser, M., & Buder, A. (2023). Simultaneous physiological measurements with five devices at different cognitive and physical loads (version 1.0.2) [Data set]. PhysioNet. https://doi.org/10.13026/wce5-fj54
Dogan, A., Bishnoi, A., Sowers, R. B., & Hernandez, M. E. (2025). Continuous heart rate recovery monitoring with ECG signals from wearables: Identifying risk groups in the general population. IEEE Journal of Biomedical and Health Informatics, 29(8), 5493–5502. https://doi.org/10.1109/JBHI.2025.3550092
SummaryThe study used electrocardiogram signals recorded by sensors embedded in a Hexoskin shirt to classify heart-rate recovery in 38 participants after exercise. Groups were defined using the cohort median recovery value of 28 beats/min, and a support-vector classifier reported an area under the curve of 86%. The cohort-relative labels are not a clinical diagnosis or externally validated risk threshold.
Key FindingA classifier using Hexoskin ECG recordings from 38 participants achieved an area under the ROC curve of 0.86 for distinguishing faster from slower heart-rate recovery after exercise. The cutoff of 28 beats/min was the median in this group, not a validated clinical risk threshold.
Raw signals
AccelerationECG
Data channels
ActivityHeart RateRR Interval
Metrics
Heart Rate Recovery
HexoskinAcademic ThesisExercise Physiology & Sports ScienceClinical Medicine & Surgery
SummarySchneider evaluated gait analysis from a wearable camera embedded in glasses and a Hexoskin accelerometer vest. Four participants supplied the initial video-only validation data, and five participants completed an additional treadmill collection at five speeds from 2.0 to 3.5 mph with both sensors. Computer-vision and signal-processing methods recovered walking pace in the controlled treadmill setting, and Hexoskin acceleration features were related to treadmill-derived gait speed. The author reported that one sensor could support parametric gait analysis in this setting, while retaining both could provide richer data.
Key FindingAll eight initial video segments had a camera-derived frequency peak matching the manually annotated truth peak, and sparse optical flow produced the lowest sum of squared errors among the tested computer-vision methods. Hexoskin accelerometer Y- and Z-channel features each correlated 0.954 with treadmill-derived gait speed at the 0.01 significance level, while the camera V-channel feature was not significantly correlated with true speed. Generated and reference waveforms had coherence of 1 at the gait-frequency peak for each participant, and the author concluded that either sensor alone or both together could be considered under the controlled conditions.
Raw signals
Acceleration
HexoskinArticleOccupational Health & Human FactorsValidation & Methodology
Bläsing, D. (2017). Erfassung von individuellem Beanspruchungserleben am Arbeitsplatz über Herzratenvariabilität im Pflegebereich. Zeitschrift für Arbeitswissenschaft, 71(4), 269–278. https://doi.org/10.1007/s41449-017-0082-7
SummaryThis nursing field study used Hexoskin shirts to record raw electrocardiogram data for heart-rate-variability analysis during morning shifts and assessed whether the measures could help describe stressful events. The analysis also considered physical activity and the ambiguity of low-strain periods. Its findings caution against treating heart-rate-variability patterns as a direct label for breaks or stress.
Key FindingIn a field study using Hexoskin ECG, higher-stress phases were observed, but the researchers could not identify them clearly for three of the five nurses. Low activity was also an unreliable marker of breaks because it occurred during documentation, telephone calls and medication preparation. The rrHRV method was described as relatively robust to movement artifacts because it calculated values only when two adjacent R peaks were detected.
SummaryThis exploratory study used Hexoskin respiratory-inductance signals from four healthy women to examine time-frequency measures of paradoxical breathing during sitting and lying simulations with different airway resistances and a weighted vest. Outcomes included phase angle, gain and coherence. The small awake simulation was not a diagnostic study in patients with sleep apnea, asthma or obesity.
Key FindingCoherence decreased under total obstruction in some comparisons, while overall gain and phase-angle effects were inconsistent across posture and obstruction conditions. Low coherence produced missing phase and gain values, and participant responses varied substantially. The weighted vest reproduced only added thoracic and abdominal load, and the four-person healthy sample does not establish clinical detection of paradoxical breathing or obesity-related effects.
Eguchi, K., Barth, A., & Spicher, N. (2024). Benchmarking open-source algorithms for QRS detection and RRI editing in textile electrocardiography. In 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 1–6). IEEE. https://doi.org/10.1109/EMBC53108.2024.10782192
SummaryResearchers benchmarked 12 open-source QRS-detection algorithms and a downstream RR-interval editing step using single-lead Hexoskin ECG from 13 healthy adults performing several activities. The comparison used a 100 ms matching tolerance and included added baseline, muscle and electrode-motion noise. It was an algorithm benchmark rather than a clinical diagnostic or patient-outcome study.
Key FindingOn single-lead Hexoskin ECG, xqrs had the highest combined precision and sensitivity among the 12 detectors, with mean sensitivity 0.996 and precision 0.991 in the primary condition. For three participants with more false positives, RR-interval editing improved precision but reduced sensitivity. False-negative interpolation remained future work, and the 13-person healthy dataset does not establish performance in post-hospital patients.
Elliot, C. A., Hamlin, M. J., & Lizamore, C. A. (2019). Validity and Reliability of the Hexoskin Wearable Biometric Vest During Maximal Aerobic Power Testing in Elite Cyclists. Journal of Strength and Conditioning Research, 33(5), 1437–1444. https://doi.org/10.1519/JSC.0000000000002005
SummaryTen male elite cyclists completed two progressive cycling tests to exhaustion 3–4 days apart. Hexoskin heart rate, breathing frequency and estimated minute ventilation were compared with laboratory measurements. Heart rate and breathing frequency showed strong agreement through most work-rate stages, while ventilation estimates were less accurate, particularly at high intensity.
Key FindingIn 10 elite male cyclists, Hexoskin heart rate correlated at least 0.98 with the laboratory reference across work rates. Breathing frequency correlated at least 0.95 through 75% of maximum work rate, but estimated minute ventilation had larger errors, particularly at high intensity.
Raw signals
ECGRespiration
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinAcademic ThesisClinical Medicine & SurgeryOccupational Health & Human Factors
Ismail, E. (2023). Assessment of psychological stress on the clinical performance experienced by paramedic students during clinical assessments [Doctoral dissertation, Durban University of Technology]. DUT Open Scholar. https://doi.org/10.51415/10321/5265
SummaryThis exploratory study compared 56 undergraduate paramedic students completing final-term clinical assessments with 15 students completing mock classroom assessments. Hexoskin recorded heart rate, respiratory rate and heart-rate variability; questionnaires and saliva assays supplied separate psychological and biomarker measures. Valid Hexoskin streams were available for 53 participants. The groups were purposefully sampled rather than randomly assigned.
Key FindingElevated anxiety was reported in 49 of 56 assessment participants, and 33% did not pass the final-term assessment. Heart rate was higher in the assessment group before and during the activity, but not afterward; heart-rate-variability findings were mixed. The mock-assessment control could also experience stress, and the observational design does not show that anxiety caused performance differences.
Data channels
Breathing RateHeart Rate
HexoskinConference AbstractClinical Medicine & SurgeryOccupational Health & Human Factors
Engelbrecht, A., Baylon, G., Dwivedi, P., Soghier, L., & Wolfe, A. (2026). Heart Rate Variability as a Marker of Stress in Trainee Performance of Critical Procedures [Conference abstract 1260]. Critical Care Medicine, 54(3S). https://doi.org/10.1097/01.ccm.0001187036.71827.02
Hedge, E. T. (2020). Wearable Sensor Technology and Machine Learning for Prediction of Oxygen Uptake and Extraction of Kinetics during Moderate and Heavy Intensity Exercise [Master's thesis, University of Waterloo]. UWSpace. http://hdl.handle.net/10012/16138
SummaryThis thesis included two related exercise studies. One used eight healthy adults to evaluate a frequency-domain indicator of oxygen-uptake response kinetics; the other used 15 healthy adults to develop a random-forest oxygen-uptake model from Hexoskin-derived heart-rate and respiratory features. A separate seven-person dataset selected the tree count, and model performance was evaluated with leave-one-participant-out testing.
Key FindingAcross three exercise conditions, predicted oxygen uptake had a repeated-measures correlation of 0.911 with direct measurements and bias of 0.022 L/min. Predicted response kinetics were slower and only moderately correlated with measurements. The model required individual maximum heart rate and calibrated ventilation, limiting use outside the laboratory, and the distinct study and tuning groups must not be combined.
Raw signals
ECGRespiration
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human Factors
Evans, L. V., Ray, J. M., Bonz, J. W., Joseph, M., Gerwin, J. N., Dziura, J. D., Venkatesh, A. K., & Wong, A. H. (2022). Improving patient and clinician safety during COVID-19 through rapidly adaptive simulation and a randomised controlled trial: a study protocol. BMJ Open, 12(5), e058980. https://doi.org/10.1136/bmjopen-2021-058980
SummaryThis study protocol combines interviews and field observation to refine a simulation-preparedness program for emergency physicians, followed by a planned randomized trial. Participants would complete four shift recordings, with randomization after the first two. Hexoskin would measure heart rate and heart-rate variability, while post-shift anxiety would be measured separately with the State-Trait Anxiety Inventory.
Key FindingThe protocol specifies Hexoskin cardiac monitoring and would enroll 42 physicians per group and compare a three-hour CRI:SIS intervention with control using on-shift heart-rate variability and post-shift anxiety. Four shift recordings and five-minute analysis periods were specified. These are planned methods, not completed enrollment, measurements or treatment effects; the protocol does not establish reduced stress, improved preparedness or patient benefit.
Raw signals
ECG
Data channels
Heart Rate
HexoskinAcademic ThesisExercise Physiology & Sports ScienceOccupational Health & Human Factors
Mansouri, F. (2024). Upper vs whole body cooling during exercise with thermal protective clothing in the heat [Master's thesis, University of Manitoba]. MSpace. http://hdl.handle.net/1993/38169
SummaryEight healthy adults completed exercise in heat while wearing firefighter turnout gear under no-cooling, upper-body-cooling and whole-body-cooling conditions. A Hexoskin tank-top measured heart rate, while separate instruments measured core temperature, skin temperature and oxygen consumption. All participants completed three exercise bouts with both cooling systems, whereas none began the third no-cooling bout. Both cooling conditions reduced several measures of strain relative to no cooling, but whole-body cooling showed an additional core-temperature advantage only during the third bout.
Key FindingAll eight participants completed the exercise bouts with upper-body and whole-body cooling, while none began the third no-cooling bout. Both cooling systems reduced perceived exertion and breathing discomfort relative to no cooling, but skin-wetness responses differed: wetness rose during the first bout with no cooling and upper-body cooling, but not with whole-body cooling. The additional whole-body-cooling advantage for limiting core-temperature rise appeared only in the third bout, and applicability to operational firefighting tasks remains uncertain.
Data channels
Heart Rate
HexoskinArticleClinical Medicine & SurgeryCardiology & Arrhythmia
Fatisson, J., Oswald, V., Mullié, Y., Gosselin Boucher, V., Verfaille, V., Comtois, A. S., & Lalonde, F. (2021). Effets de manipulations ostéopathiques visant le péricarde sur le système nerveux autonome : une étude pilote. La Revue de l'Ostéopathie, 27-2, 43–54. https://www.larevuedelosteopathie.com/articles/174/
SummaryThis pilot study examined heart-rate variability after visceral osteopathic manipulations directed at pericardial attachments. Sixty-four healthy adults aged 25–35 were assigned to manipulation, simulated-manipulation or no-intervention groups. Hexoskin recorded heart rate, and five-minute segments were analyzed in time and frequency domains over several study visits.
Key FindingHeart-rate-variability measures derived from Hexoskin cardiac recordings showed mixed results. RMSSD decreased across all 64 participants from the initial to final measurement, and some frequency-domain differences appeared between manipulation and simulated-manipulation conditions. The study did not provide consistent evidence that the techniques changed heart-rate variability; the healthy 25–35-year-old sample and different assignment process for the no-intervention group limit conclusions about treatment effects.
Data channels
Heart Rate
Metrics
RMSSD
HexoskinConference AbstractExercise Physiology & Sports ScienceOccupational Health & Human Factors
Fox, N., Davis, J. E., Brown, A., Deel, N., Montoye, A., Molesky, M., Achatz, E., Miller, M., Reitinger, J., Reno, E., Yaeger, L., Wislowski, A., Subudhi, A., & Roach, R. (2017). Assessing physiological function during a high-altitude hike using real-time monitoring [Conference abstract]. Medicine & Science in Sports & Exercise, 49(5S), 764. https://doi.org/10.1249/01.mss.0000519034.56031.a1
Frade, M. C. M., Beltrame, T., Viana, D. R., Da Silva, M. M. C., Gois, M. D. O., De Facio, C. A., Gonzaga, L. A., Arcuri, J. F., Di Lorenzo, V. A. P., & Catai, A. M. (2021). Wearables to monitoring the activities daily living in patients post-hospitalization by COVID-19 [Conference abstract]. European Respiratory Journal, 58(Suppl. 65), PA2271. https://doi.org/10.1183/13993003.congress-2021.PA2271
Frade, M. C. M., Beltrame, T., Gois, M. de O., Pinto, A., Tonello, S. C. G. de M., Torres, R. da S., & Catai, A. M. (2023). Toward characterizing cardiovascular fitness using machine learning based on unobtrusive data. PLOS ONE, 18(3), e0282398. https://doi.org/10.1371/journal.pone.0282398
SummaryThe study combined seven days of longitudinal Hexoskin heart-rate, respiratory and movement data with demographic measures from 43 participants. These inputs were used to estimate cardiopulmonary-exercise-test VO2max. A support-vector-regression model was evaluated with nine-fold cross-validation, and SHAP analysis described the contribution of model inputs.
Key FindingEstimates of VO2max based on longitudinal Hexoskin data and demographic measures correlated with measured VO2max (Pearson r = 0.804), with mean absolute error of 0.38 ± 0.13 L/min and mean difference of 0.038 L/min. Age ranked highest among the model inputs, followed by heart rate, height, weight and acceleration. Internal cross-validation does not establish external performance or accuracy within the study's small clinical subgroups.
Furberg, R., Ortiz, A. M., McCombs, M., Cress, M., Thornburg, J., Pepper, J. K., & Lee, Y. O. (2019). Exposure to Potentially Harmful E-Cigarette Emissions via Vape Tricks: Protocol for a Mixed-Methods Study. JMIR Research Protocols, 8(4), e12304. https://doi.org/10.2196/12304
Gagliano, L., Ding, T. Y., Toffa, D. H., Beauregard, L., Robert, M., Lesage, F., Sawan, M., Nguyen, D. K., & Bou Assi, E. (2023). Decrease in wearable-based nocturnal sleep efficiency precedes epileptic seizures. Frontiers in Neurology, 13, 1089094. https://doi.org/10.3389/fneur.2022.1089094
SummaryThe study analyzed 304 nights from 47 people with confirmed epilepsy admitted to an inpatient monitoring unit. Hexoskin sleep measures were compared with seizures annotated from video EEG. Six patients with seizures every day or night were excluded, and nights were classified by whether a seizure occurred within 24 hours after awakening.
Key FindingLower sleep efficiency measured by Hexoskin was associated with greater odds of a seizure within 24 hours after awakening; higher wake time after sleep onset showed a similar association. Nights containing a nocturnal seizure also had lower sleep efficiency, more wake time and higher odds of a subsequent seizure. These inpatient night-level associations do not establish causality or prospective forecasting performance at home.
Ganapathy, N., Baumgärtel, D., & Deserno, T. M. (2021). Automatic Detection of Atrial Fibrillation in ECG Using Co-Occurrence Patterns of Dynamic Symbol Assignment and Machine Learning. Sensors, 21(10), 3542. https://doi.org/10.3390/s21103542
SummaryThe study proposed a dynamic symbolic assignment method that converts ECG RR intervals into transition features for classifying normal sinus rhythm and paroxysmal atrial fibrillation. Machine-learning performance was evaluated with public PhysioNet databases. Hexoskin and a capacitive ECG chair were used separately to demonstrate normal-rhythm transition patterns.
Key FindingOn the public databases, reported maximum F-scores reached 94.6% for AFPDB and 99.8% for AFTDB under selected settings. These were repeated cross-validation results from database signals, not Hexoskin performance measures or an independent challenge test. The garment example showed normal-rhythm patterns only and did not establish atrial-fibrillation detection accuracy or clinical validation.
Raw signals
ECG
HexoskinAcademic ThesisData Science & Artificial IntelligenceOccupational Health & Human Factors
Using Deep Learning for Motion Analysis of 3D Motion Capture Data for Forecasting Motion and Fatigue
Hernandez, G., Jr. (2021). Using deep learning for motion analysis of 3D motion capture data for forecasting motion and fatigue [Master's thesis, Texas State University].
SummaryThis thesis used motion-capture data from 10 university participants to test LSTM and GRU models for short-term lifting-motion forecasting and prediction of self-reported exertion. Eight participants supplied training data and two supplied test data. Hexoskin heart-rate and breathing-rate measurements were collected but explicitly excluded from the analysis.
Key FindingThe preferred motion-forecasting settings used a 100 ms horizon for LSTM and a 50 ms horizon for GRU. The fatigue models did not achieve the expected result: their predictions settled near a Borg rating of 14 and did not track higher reported exertion. Findings from two test participants in a university sample do not establish performance for experienced material-handling workers or injury prevention.
HexoskinArticleOccupational Health & Human FactorsData Science & Artificial IntelligenceCardiology & ArrhythmiaValidation & Methodology
Gerasimova-Meigal, L., Meigal, A., Dimitrov, V., Gerasimova, M., Sklyarova, A., Smirnov, N., & Kostyukov, V. (2023). Assessment of stress level with help of “smart clothing” sensors, heart rate variability-based markers and machine learning algorithms. Engineering Proceedings, 58, 20. https://doi.org/10.3390/ecsa-10-16173
SummaryNineteen healthy adults aged 19–55 contributed laboratory or daily-life recordings for a wearable stress-prediction study. Fifteen completed laboratory testing, and eight contributed field recordings. Hexoskin heart-rate data were converted into heart-rate-variability features and paired with self-reported stress ratings for comparison of five regression models.
Key FindingIn a comparison using features derived from Hexoskin heart-rate data, the random forest produced the highest reported correct-entry rate at 86.3%, while CatBoost reached 85.3% and processed each record in about 2.02 ms. More than 70% of segments represented low stress ratings of 2–3, limiting the range used for training and evaluation. The small study does not establish clinical stress diagnosis or performance across more diverse stress levels.
Raw signals
ECG
Data channels
Heart RateRR Interval
HexoskinArticleCardiology & ArrhythmiaRespiratory & Infectious DiseaseOccupational Health & Human FactorsValidation & Methodology
Gerasimova-Meigal, L., Meigal, A., Dimitrov, V., Gerasimova, M., & Sklyarova, A. (2024). “Smart clothing” technology for heart function monitoring during a session of “dry” immersion. Engineering Proceedings, 82, 24. https://doi.org/10.3390/ecsa-11-20475
SummaryEight healthy young adults wore a Hexoskin Smart Shirt during a 45-minute dry-immersion session. The session was used as a ground-based model of weightlessness. ECG-derived heart-rate variability and respiratory rate were analyzed in five-minute segments, with motion during blood-pressure measurement introducing some signal noise.
Key FindingDuring dry immersion, heart rate measured with Hexoskin fell by a further 5–10 beats/min, while SDNN and sample entropy changed significantly. Respiratory rate decreased from 16 to 13 breaths/min, but this change was not statistically significant, and several other heart-rate-variability measures did not change significantly. The small healthy cohort and ground-based analogue do not establish clinical or spaceflight performance.
Raw signals
ECG
Data channels
Breathing RateHeart RateRR Interval
HexoskinArticleOccupational Health & Human FactorsData Science & Artificial IntelligenceCardiology & ArrhythmiaValidation & Methodology
Gerwin, J. N., de Oliveira Almeida, G., Boyce, M. W., Joseph, M., Wong, A. H., Burleson, W., & Evans, L. V. (2024). HRVEST: A novel data solution for using wearable smart technology to measure physiologic stress variables during a randomized clinical trial. Frontiers in Computer Science, 6, 1343139. https://doi.org/10.3389/fcomp.2024.1343139
SummaryResearchers developed HRVEST to process Hexoskin ECG from a clinical trial involving 81 emergency physicians and 324 work-shift recordings. The open-source workflow converted files and synchronized metadata. It then divided recordings into five-minute windows, corrected artifacts, classified signal quality and calculated heart-rate-variability measures from a 347 GB dataset.
Key FindingThe HRVEST workflow for Hexoskin cardiac recordings processed 413 ECG recordings in an average of 15 minutes 28 seconds on the reported laptop and retained 99.7% usable data after artifact correction. Run time increased roughly linearly with file count, but depended on hardware and selected options. This was a processing-methods evaluation, not validation of physiological stress measurement or a clinical outcome study.
Gharbi, O., Lamrani, Y., St-Jean, J., Jahani, A., Toffa, D. H., Tran, T. P. Y., Robert, M., Nguyen, D. K., & Bou Assi, E. (2024). Detection of focal to bilateral tonic-clonic seizures using a connected shirt. Epilepsia, 65(8), 2280–2294. https://doi.org/10.1111/epi.18021
SummaryForty-two adults with epilepsy wore a Hexoskin connected shirt during simultaneous hospital video-EEG monitoring. An XGBoost pipeline used ECG and accelerometer features to detect 66 focal-to-bilateral tonic-clonic seizures. Respiratory signals were recorded but were not included in the analysis.
Key FindingUsing Hexoskin ECG and acceleration data from 42 hospitalized adults with epilepsy, an offline model detected 56 of 66 focal-to-bilateral tonic-clonic seizures (84.8% sensitivity), with a median of 0.55 false alarms per 24 hours. The study did not test real-time detection at home.
GholamHosseini, H., Baig, M., Maratas, J., Mirza, F., & Lindén, M. (2019). Obesity risk assessment model using wearable technology with personalized activity, calorie expenditure and health profile. Studies in Health Technology and Informatics, 261, 91–96. https://pubmed.ncbi.nlm.nih.gov/31156097/
SummaryThe study described a smartphone prototype for individualized activity and overweight-or-obesity risk profiling. It combined Hexoskin activity and vital-sign data with user-reported calorie intake and normalized selected variables using standard limits drawn from best-practice and national guidelines. The resulting weighted score was used to propose daily calorie plans.
Key FindingThe prototype combining body mass index with Hexoskin measurements assigned 50% of its overall weight to body mass index and 12.5% each to heart rate, breathing rate, minute ventilation and caloric expenditure. The authors reported training with 36 PhysioNet patient records and testing with randomly generated data. No prospective clinical evaluation, diagnostic accuracy or weight-loss benefit was reported, and future self-learning behavior was only proposed.
Gholam Hosseini, H., Baig, M. M., & Lindén, M. (2020). A smartphone-based obesity risk assessment application using wearable technology with personalized activity, calorie expenditure and health profile. European Journal for Biomedical Informatics, 16(2), 22–28. https://doi.org/10.24105/ejbfi.2020.16.2.5
SummaryThis development paper described a smartphone prototype that combined body mass index, user-reported information and averaged Hexoskin heart-rate, breathing, ventilation, cadence and calorie data. Three male project students aged 21–23 initially tested one week of garment collection. The app calculated an overall score and selected activity and dietary plans.
Key FindingThe prototype, which included Hexoskin cardiac, respiratory and activity data, weighted body mass index at 50% of its overall score and heart rate, breathing rate, minute ventilation and caloric expenditure at 12.5% each. Evaluation also used synthetically generated values, which were not participant or wearer records. The paper did not report prospective clinical validation, diagnostic accuracy or weight-loss outcomes; continuous self-learning was described only as future work.
Gossett, E. W., Piscopo, C., Hughes, J. M., Khan, S., Wakely, S., Salinas-Aguayo, A., Parker, T., Henning, R. A., & Kim, I. (2025). Enhancing ecological validity in wearable sensor stress research: A novel laboratory paradigm integrating cognitive, physical, and social-evaluative demands. Proceedings of the Human Factors and Ergonomics Society Annual Meeting, 69(1), 1313–1318. https://doi.org/10.1177/10711813251371653
SummaryTwenty university students completed a laboratory protocol combining cognitive workload, evaluator presence and light cycling. A Hexoskin smart shirt recorded ECG, respiration and movement, while self-reports and interviews measured perceived stress. Technical issues left ECG available for 16 participants, and only cardiovascular measures were compared statistically.
Key FindingMean and maximum heart rate derived from Hexoskin ECG were higher during the stress trial than the control trial, while the heart-rate-variability measure RMSSD showed no significant trial effect. Self-reported distress, challenge and threat also differed across conditions. The preliminary student study had missing physiological records and does not establish performance outside the laboratory or in military populations discussed as a future application.
Raw signals
ECG
Data channels
Heart Rate
Metrics
HR MaxRMSSD
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human FactorsValidation & Methodology
Grantcharov, P. D., Boillat, T., Elkabany, S., Wac, K., & Rivas, H. (2019). Acute mental stress and surgical performance. BJS Open, 3(1), 119–125. https://doi.org/10.1002/bjs5.104
SummaryOne attending surgeon wore a Hexoskin Smart Shirt during 25 consecutive elective laparoscopic and endoscopic procedures. Time-stamped ECG-derived heart-rate variability and procedure video were divided into one-, two- and five-minute intervals. Technical events in the laparoscopic procedures were rated with the Operating Room Black Box and Generic Error Rating Tool.
Key FindingAcross intervals analyzed using one surgeon’s Hexoskin ECG recordings, surgical-event rates were 47–66% higher in higher heart-rate-variability stress quantiles than in lower quantiles; the strongest association used one-minute RMSSD intervals. Data came from one surgeon, and technical performance was assessed only for gastric bypass and sleeve gastrectomy. The observational association does not establish whether stress caused events or events increased stress.
Gross, M. J., Hall, R., Bringer, J. D., Cook, C. J., Kilduff, L. P., & Shearer, D. A. (2017). Resonant frequency training in elite sport: A case study example. Journal of Sport Psychology in Action, 8(3), 173–183. https://doi.org/10.1080/21520704.2017.1287797
SummaryThis applied case study followed resonant-frequency breathing training in one 45-year-old elite Olympic Trap shooter. During a simulated competition, Hexoskin respiration and acceleration were synchronized to identify shots and examine breathing between them. The athlete reported that the garment did not affect her shooting.
Key FindingThe athlete reproduced her individualized breathing pattern between shots with some variability, and heart-rate variability increased during separate paced-breathing exercises. Hexoskin ECG quality during the simulated competition was insufficient for heart-rate-variability analysis. Reported improvements in calm, control and shooting performance came from the athlete and coach; the uncontrolled single case and absent pre-intervention baseline do not establish a training effect.
Raw signals
AccelerationRespiration
Data channels
Breathing Rate
HexoskinArticleNeuroscience, Sleep & CognitionOccupational Health & Human Factors
Guertin-Lahoud, S., Coursaris, C. K., Sénécal, S., & Léger, P.-M. (2023). User Experience Evaluation in Shared Interactive Virtual Reality. Cyberpsychology, Behavior, and Social Networking, 26(4), 263–272. https://doi.org/10.1089/cyber.2022.0261
SummaryIn a field study, 28 adults experienced virtual reality alone or in pairs while wearing a Hexoskin Smart Garment for heart-rate and movement measurement. The experience included a 30-minute active standing phase and an eight-minute passive seated phase. Questionnaires completed after both phases assessed presence, immersion, flow, anxiety, affect and copresence.
Key FindingIn a virtual reality study that tracked heart rate and movement with Hexoskin, paired participants reported greater copresence and more positive affect than solo participants. Presence, immersion, flow and state anxiety did not differ significantly, and neither heart rate nor physical movement changed significantly between groups. The convenience sample and field design support an experiential comparison, but they do not establish a physiological effect of shared virtual reality.
Gutta, S., Cheng, Q., & Benjamin, B. A. (2015). Control mechanism modeling of human cardiovascular-respiratory system. In 2015 IEEE Global Conference on Signal and Information Processing (GlobalSIP) (pp. 918–922). IEEE. https://doi.org/10.1109/GlobalSIP.2015.7418331
Data channels
Heart Rate
HexoskinArticleExercise Physiology & Sports ScienceNeuroscience, Sleep & CognitionClinical Medicine & SurgeryOccupational Health & Human Factors
Hajj-Boutros, G., Sonjak, V., Faust, A., Balram, S., Lagacé, J.-C., St-Martin, P., Divsalar, D. N., Sadeghian, F., Liu-Ambrose, T., Blaber, A. P., Dionne, I. J., Duchesne, S., Kontulainen, S., Theou, O., & Morais, J. A. (2024). Myths and Methodologies: Understanding the health impact of head down bedrest for the benefit of older adults and astronauts. Study protocol of the Canadian Bedrest Study. Experimental Physiology, 109(5), 812–827. https://doi.org/10.1113/EP091473
SummaryThe Canadian Bedrest Study used a two-arm randomized, non-blinded design in 23 healthy adults aged 55–65. Its 26-day schedule included 14 days of six-degree head-down bed rest and seven recovery days; half the participants received prescribed resistance and endurance exercise. Hexoskin recorded ECG, respiration and acceleration during designated 24-hour periods.
Key FindingIn the Canadian Bedrest Study, which used Hexoskin for physiological monitoring, 22 of 23 participants completed the bed-rest phase; one withdrew on day 3. Two control participants later withdrew from follow-up after atrial-fibrillation episodes that the ethics committee judged unrelated to the study. This protocol and methodology report coordinates broad physiological, cognitive and biomarker outcomes, but it does not provide comparative results establishing benefit from the exercise countermeasure, and its highly selected healthy cohort limits generalizability.
Lindquist, H. R. (2025). Neural correlates of motor control and stress response during ambidextrous polyrhythmic drumming: An examination into how different musical genres influence autonomic nervous system responses during individual instrumental practice [Manuscript]. NeuroDrummingLab. https://neurodrumminglab.com/Documents/Grooves_and_Stress-JournalArticle_v2.pdf
Haddad, M., Dalansi, F., Kharbach, M., Mohamed, A., & Aganovic, Z. (2019). Convergent validity and relative reliability of Hexoskin during a maximal field test [Conference abstract]. Medicine & Science in Sports & Exercise, 51(6S), 923. https://doi.org/10.1249/01.mss.0000563264.18648.9a
Hadid, A., McDonald, E. G., Cheng, M. P., Papenburg, J., Libman, M., Dixon, P. C., & Jensen, D. (2023). The WE SENSE study protocol: A controlled, longitudinal clinical trial on the use of wearable sensors for early detection and tracking of viral respiratory tract infections. Contemporary Clinical Trials, 128, 107103. https://doi.org/10.1016/j.cct.2023.107103
SummaryThe WE SENSE protocol describes a controlled longitudinal trial using wearable sensors around a low-grade influenza-vaccine challenge. The protocol planned to recruit 60 healthy adults, and 58 had enrolled by manuscript review. Astroskin was one of three complementary wearable platforms and the reference device for sleep, electrocardiography, and respiration monitoring. Planned monitoring covered 12 days: 7 days before and 5 days after vaccine administration. Data retrieval and sample analysis were still ongoing at protocol review, so no outcome results were reported.
Key FindingIn the WE SENSE protocol, which includes Astroskin monitoring, the primary planned outcome was within-person change in physiological and activity measures before versus after vaccination. The secondary planned outcome was a binary classifier of within-participant infection state. F1 score, accuracy, sensitivity, and specificity were planned evaluation measures rather than reported performance results.
Hadid, A., McDonald, E. G., Cheng, M. P., Papenburg, J., Libman, M., Dixon, P. C., & Jensen, D. (2023). The WE SENSE study protocol: A controlled, longitudinal clinical trial on the use of wearable sensors for early detection and tracking of viral respiratory tract infections. Contemporary Clinical Trials, 128, 107103. https://doi.org/10.1016/j.cct.2023.107103
SummaryThe WE SENSE protocol describes a controlled longitudinal trial using wearable sensors around a low-grade influenza-vaccine challenge. The protocol planned to recruit 60 healthy adults, and 58 had enrolled by manuscript review. Astroskin was one of three complementary wearable platforms and the reference device for sleep, electrocardiography, and respiration monitoring. Planned monitoring covered 12 days: 7 days before and 5 days after vaccine administration. Data retrieval and sample analysis were still ongoing at protocol review, so no outcome results were reported.
Key FindingIn the WE SENSE protocol, which includes Astroskin monitoring, the primary planned outcome was within-person change in physiological and activity measures before versus after vaccination. The secondary planned outcome was a binary classifier of within-participant infection state. F1 score, accuracy, sensitivity, and specificity were planned evaluation measures rather than reported performance results.
Hadid, A., McDonald, E. G., Ding, Q., Phillipp, C., Trottier, A., Dixon, P. C., Jlassi, O., Cheng, M. P., Papenburg, J., Libman, M., & Jensen, D. (2025). Development of machine learning prediction models for systemic inflammatory response following controlled exposure to a live attenuated influenza vaccine in healthy adults using multimodal wearable biosensors in Canada: a single-centre, prospective controlled trial. The Lancet Digital Health, 7(7), 100886. https://doi.org/10.1016/j.landig.2025.100886
SummaryThe WE SENSE trial examined whether machine learning could detect within-person physiological and activity changes surrounding a live attenuated influenza vaccine challenge. A secondary binary classifier predicted an individualized systemic-inflammatory state from wearable and symptom data. Night-time and daytime Astroskin/Hexoskin features were evaluated as part of this controlled challenge. The study does not establish diagnosis of naturally acquired respiratory infection.
Key FindingAdding night-time and daytime Astroskin/Hexoskin data yielded a reported 24-hour-tolerance ROC-AUC of 0.91, specificity of 0.83 and F1 score of 0.65. The high-sensitivity threshold produced some overprediction at moderate inflammatory-response levels. These results come from a controlled healthy-adult challenge and were not externally validated for clinical diagnosis.
Raw signals
AccelerationECGRespiration
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human Factors
Haffar, A., Khan, I. A., Ong, C., Magnuson, J. A., Austin, M. S., Krueger, C. A., & Lonner, J. H. (2022). Stress and strain during total joint arthroplasty are not impacted by hand dominance or operative laterality in orthopedic surgeons. The Journal of Arthroplasty, 37(6), 1054–1058. https://doi.org/10.1016/j.arth.2022.02.073
SummaryThree high-volume arthroplasty surgeons were monitored during conventional knee and hip arthroplasty in a prospective cohort study. A Hexoskin Smart Vest recorded cardiorespiratory measures and energy expenditure. Operative-limb laterality was not associated with significant differences in the measured variables for right- or left-handed surgeons. Findings about surgeon position came from this small specialist sample and were judged unlikely to be clinically significant.
Key FindingHexoskin cardiorespiratory and energy-expenditure variables did not differ significantly by operative-limb laterality for either right- or left-handed surgeons. During knee arthroplasty, consistently standing on the hand-dominant side was associated with higher HRV and lower minute ventilation, but the authors judged these differences unlikely to be clinically significant. Results from three high-volume surgeons do not establish effects on patient outcomes or broader surgical populations.
Haffar, A., Krueger, C. A., Goh, G. S., & Lonner, J. H. (2022). Total knee arthroplasty with robotic surgical assistance results in less physician stress and strain than conventional methods. The Journal of Arthroplasty, 37(6S), S193–S200. https://doi.org/10.1016/j.arth.2021.11.021
SummaryThis study monitored one surgeon during 40 consecutive unilateral knee arthroplasties, comparing 20 robotic-assisted with 20 conventional procedures. Hexoskin Smart Garments worn under surgical scrubs collected cardiorespiratory and caloric-expenditure measures as physiological-stress surrogates alongside wearable ergonomic measurements. Robotic cases took longer but had lower calorie expenditure per minute and lower mean heart rate. Whether these differences reduce surgeon pain or injury remains unknown.
Key FindingIn one surgeon monitored with Hexoskin, robotic-assisted knee arthroplasty took longer but had lower calorie expenditure per minute and lower mean heart rate than conventional surgery in this single-surgeon series. Robotic cases also involved less time in demanding lumbar flexion, while several neck and shoulder measures did not differ. The study did not establish that these physiological and ergonomic differences reduce musculoskeletal pain or injury.
Haffar, A., Krueger, C. A., Goh, G. S., & Lonner, J. H. (2023). UKA with a handheld robotic device results in greater surgeon physiological stress than conventional instrumentation. Knee Surgery, Sports Traumatology, Arthroscopy, 31(3), 777–785. https://doi.org/10.1007/s00167-022-06908-5
SummaryThe study compared one surgeon during 15 robotic-assisted and 15 conventional unicompartmental knee arthroplasties. Hexoskin garments collected cardiorespiratory and caloric-expenditure data beneath surgical scrubs. Robotic cases took longer and used more calories, while HRV, breathing rate and minute ventilation did not differ significantly. The handheld device reduced neck flexion but increased shoulder abduction, so the expected overall ergonomic and physiological advantages were not realized.
Key FindingFor one surgeon wearing Hexoskin, robotic unicompartmental knee arthroplasty involved greater heart rate and total calorie expenditure than conventional instrumentation, while HRV, breathing rate and minute ventilation did not differ significantly. The handheld device reduced neck flexion but increased shoulder abduction. These findings came from one surgeon and do not establish patient outcomes or broader ergonomic benefit.
Halidane, C., Bluteau, J., Pillarella, S., & Kirakoya, F. (2024). Impact of flexible seating on the quality of teacher-student interactions with coping to stress adaptation and mental health of elementary students in Quebec. International Journal of Health Promotion and Education, 62(4), 325–338. https://doi.org/10.1080/14635240.2023.2212373
SummaryThis study compared 107 Quebec students in three flexible-seating and three fixed-seating classes. Student mental-health measures were analyzed by gender, and teacher data were summarized by group. Girls in flexible classrooms had lower mean scores across the four reported mental-health indicators, while boys had lower school-problem scores but higher scores on the other measures. Nocturnal heart-rate variability in the 45-student subsample, recorded over two consecutive nights with Hexoskin biometric vests, did not differ between seating groups for either gender. The observational classroom comparison does not establish that seating caused the reported differences.
Key FindingAcross all students, none of the four mental-health group comparisons reached the paper’s significance threshold. Gender-stratified results differed: several scores were lower for girls in flexible classrooms, whereas boys in flexible classrooms had higher internalizing, inattention/hyperactivity and emotional-symptom scores. Nocturnal heart-rate variability assessed using Hexoskin showed no seating-group difference in the 45-student subsample, and the nonrandomized classroom design limits causal interpretation.
Harbour, E., Lasshofer, M., Genitrini, M., & Schwameder, H. (2021). Enhanced Breathing Pattern Detection during Running Using Wearable Sensors. Sensors, 21(16), 5606. https://doi.org/10.3390/s21165606
SummaryTwelve runners completed a synchronized incremental treadmill protocol to exhaustion while wearing a Hexoskin smart shirt, RIP sensors and reference spirometry. A custom algorithm filtered and segmented the RIP data to estimate flow reversals and breathing patterns. It identified more than 99% of reference flow reversals, with pooled precision and recall of 0.998 and mean lag of 0.018 s (−0.067, 0.104). Performance was strongest for flow-reversal detection and breathing rate; other breathing-pattern components were less consistent.
Key FindingA custom algorithm for analyzing Hexoskin respiratory-band signals identified more than 99% of flow reversals, with pooled precision and recall of 0.998 and mean lag of 0.018 s (−0.067, 0.104). Breath-cycle time and breathing rate showed low bias and error, while duty cycle showed systematic error and breathing-rate variability had high relative error at low values. Results from 12 runners in a masked laboratory treadmill test do not establish field performance or accuracy for other respiratory measures.
Harbour, E., van Rheden, V., Schwameder, H., & Finkenzeller, T. (2023). Step-adaptive sound guidance enhances locomotor-respiratory coupling in novice female runners: A proof-of-concept study. Frontiers in Sports and Active Living, 5, 1112663. https://doi.org/10.3389/fspor.2023.1112663
SummaryResearchers tested real-time, step-adaptive sound guidance for locomotor-respiratory coupling in 16 novice-to-intermediate female runners. Hexoskin tracked respiration and cadence during indoor and outdoor step-rate-feedback runs followed by individualized breathing-cue trials. Guidance increased step-breath synchronization in the sequential within-subject comparison. The acute, nonrandomized proof of concept had no separate no-sound control and did not assess long-term learning or metabolic benefit.
Key FindingIn runners whose respiration and cadence were tracked with Hexoskin, step-adaptive guidance increased indoor and outdoor locomotor-respiratory attachment, although reported outdoor baseline values differ slightly between the Results and table. Outdoor breathing-rate variability and expiratory entrainment stability improved, while the overall inspiratory-stability effect was nonsignificant. The small sequential study lacked randomization, a true no-sound control and an accepted reference for overall coupling accuracy.
Raw signals
AccelerationRespiration
Data channels
Cadence
HexoskinArticleValidation & MethodologyClinical Medicine & SurgeryCardiology & Arrhythmia
Hardon, H. J., Van Kerkhof, Y. N., Bartelds, B., Kammeraad, J. A. E., & Van Deutekom, A. W. (2025). The Validation and Accuracy of Wearable Heart Rate Trackers in Children With Heart Disease: Prospective Cohort Study. JMIR Formative Research, 9, e70835. https://doi.org/10.2196/70835
SummaryThis pediatric cardiology study compared a Hexoskin smart shirt and Corsano CardioWatch with 24-hour Holter ECG. The Hexoskin analysis included 36 children and found mean heart-rate accuracy of 87.4% (SD 11%). Accuracy fell from 94.9% in the first 12 hours to 80.0% in the second 12 hours and declined with greater movement and higher heart rates. A blinded cardiologist classified 31 of 36 Hexoskin rhythm recordings; five were obscured by artifacts or noise. Clinically significant brady- and tachyarrhythmias did not occur, so diagnostic accuracy for those rhythms was not established.
Key FindingAgainst 24-hour Holter ECG in 36 children, mean Hexoskin heart-rate accuracy fell from 94.9% in the first 12 hours to 80.0% in the second. A pediatric cardiologist classified 31 of 36 ECG rhythm strips from the shirt; clinically significant slow or fast arrhythmias did not occur, so the study could not assess detection of those rhythms.
Raw signals
AccelerationECG
Data channels
Heart Rate
HexoskinPoster / PresentationOccupational Health & Human FactorsNeuroscience, Sleep & CognitionValidation & Methodology
He, M., Cerna, J., Alkurdi, A., Dogan, A., Zhao, J., Clore, J. L., Sowers, R., Hsiao-Wecksler, E. T., & Hernandez, M. E. (2024). Physical, Social and Cognitive Stressor Identification using Electrocardiography-derived Features and Machine Learning from a Wearable Device. 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 1–4). IEEE. https://doi.org/10.1109/EMBC53108.2024.10782654
He, M., Cerna, J., Mathew, R., Zhao, J., Zhao, J., Espina, E., Clore, J. L., Sowers, R. B., Hsiao-Wecksler, E. T., & Hernandez, M. E. (2025). Objective anxiety level classification using unsupervised learning and multimodal physiological signals. Smart Health, 36, 100572. https://doi.org/10.1016/j.smhl.2025.100572
SummaryForty-four young adults completed a relaxation baseline and four laboratory anxiety-eliciting tasks while Hexoskin recorded ECG and an Empatica E4 recorded electrodermal activity and skin temperature. The analysis used baseline-normalized multimodal features and Gaussian mixture models to form two- or three-level physiological response groups without using self-report as the training label. The two-cluster solution had an average silhouette score of 0.40, while the three-cluster solution scored 0.14. With leave-one-participant-out validation, SVM accuracy was 90.9% for binary cluster labels and 73.3% for three-class labels, but the authors note overlap, modest cluster separation, and difficulty distinguishing intermediate levels.
Key FindingThe two-cluster model combining Hexoskin ECG with electrodermal activity and skin temperature from a separate device showed moderate separation with an average silhouette score of 0.40, compared with 0.14 for the three-cluster solution. Under leave-one-participant-out validation, SVM accuracy was 90.9% for binary cluster labels and 73.3% for three-class labels, while the three-class psychophysiological groups were not statistically distinct.
Hedge, E. T., Hughson, R. L., & Dominelli, P. B. (2022). Repeatability and reproducibility of changes in thoracoabdominal compartmental volumes and breathing pattern during low-, moderate- and heavy-intensity exercise. European Journal of Applied Physiology, 122(5), 1217–1229. https://doi.org/10.1007/s00421-022-04917-3
SummaryTen healthy adults enrolled in a protocol with one ramp cycling test and two step-test visits, but only seven had paired step-test data; Hexoskin respiratory bands measured thoracic and abdominal motion. A separate turbine-based metabolic system measured tidal volume, breathing rate, minute ventilation, and gas exchange. Relative compartment contributions during repeated step exercise had ICCs of 0.87 at low, 0.89 at moderate, and 0.93 at heavy intensity. At matched minute ventilation, tidal volume and breathing rate showed no statistically significant difference between ramp and step protocols, although calibration limitations restricted ramp-test compartment comparisons to motion indices rather than absolute volumes.
Key FindingAmong the seven participants with paired step-test data, thoracic and abdominal contributions measured with Hexoskin respiratory bands to tidal volume were highly repeatable across low, moderate, and heavy step exercise, with ICCs of 0.87, 0.89, and 0.93. At matched minute ventilation, tidal volume and breathing rate showed no statistically significant difference between ramp and step protocols, but ramp-test compartment signals could not be reliably calibrated to absolute volumes and were analyzed as motion indices.
Hedge, E. T., Amelard, R., & Hughson, R. L. (2023). Prediction of oxygen uptake kinetics during heavy-intensity cycling exercise by machine learning analysis. Journal of Applied Physiology, 134(6), 1530–1536. https://doi.org/10.1152/japplphysiol.00148.2023
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinArticleOccupational Health & Human FactorsData Science & Artificial IntelligenceValidation & Methodology
Hefied, Y. K., Aribi, D., Demesure, G., & Bril El-Haouzi, H. (2026). A data-driven approach for tailored fatigue modeling in the context of production planning and control. Computers & Industrial Engineering, 216, 111997. https://doi.org/10.1016/j.cie.2026.111997
SummaryNine project-consortium participants completed 11 controlled manual-assembly sessions after a 20-minute rest, with approximately 1.0–1.3 hours of work per session. Hexoskin supplied 1 Hz heart rate and breathing rate, Xsens supplied 100 Hz motion data for posture and RULA scoring, and Borg ratings captured perceived fatigue every 5–6 minutes. The hybrid framework used a data-driven fatigue estimate to calibrate either the theoretical model’s fatigue rate or its work/rest input signal, reducing session-level mean squared error in both approaches. The small cohort, limited repeated sessions, literature-derived membership functions, and access to only two Hexoskin metrics make the findings preliminary rather than evidence of a deployable production-planning system.
Key FindingAcross 11 controlled assembly sessions from nine participants, both adaptation strategies reduced mean squared error between the initial theoretical fatigue model and the data-driven estimate. The evaluation is preliminary: Hexoskin access was limited to heart rate and breathing rate, the cohort was small, and repeated sessions within each participant were insufficient for within-person validation.
Data channels
Breathing RateHeart Rate
HexoskinConference PaperOccupational Health & Human FactorsData Science & Artificial Intelligence
Hernandez, G., Valles, D., Wierschem, D. C., Koldenhoven, R. M., Koutitas, G., Mendez, F. A., Aslan, S., & Jimenez, J. (2020). Machine Learning Techniques for Motion Analysis of Fatigue from Manual Material Handling Operations Using 3D Motion Capture Data. In 2020 10th Annual Computing and Communication Workshop and Conference (CCWC) (pp. 300–305). IEEE. https://doi.org/10.1109/CCWC47524.2020.9031222
Higashino, M., Miyata, K., & Kudo, K. (2022). Coordination dynamics of thoracic and abdominal movements during voluntary breathing. Scientific Reports, 12(1), 13266. https://doi.org/10.1038/s41598-022-17473-9
SummarySixteen healthy adults completed paced voluntary breathing at 7.5, 15, 30, 60, and 120 breaths per minute while Hexoskin chest and waist strain gauges recorded thoracic and abdominal movement. Relative phase was near in phase at preferred breathing frequency, with a mean angle of −5.58 ± 12.63°, and the absolute phase angle moved farther from in phase as breathing frequency increased. At 120 breaths per minute, seven participants remained in phase, while two showed thoracic-leading, five abdominal-leading, and two anti-phase patterns. The changes were gradual rather than an abrupt phase transition, and the harmonica task, missing trials, unmeasured respiratory volume, and limited frequency range restrict generalization.
Key FindingChest and abdominal movement measured with Hexoskin was in phase at lower and preferred breathing frequencies, then gradually shifted toward participant-specific thoracic-leading, abdominal-leading, or anti-phase patterns as breathing frequency increased. The study found no abrupt phase transition and did not measure inhaled or exhaled air volume; harmonica breathing, discarded trials, and the limited 7.5–120 bpm range constrain interpretation.
Raw signals
AccelerationRespiration
HexoskinPoster / PresentationCardiology & ArrhythmiaOccupational Health & Human FactorsClinical Medicine & SurgeryValidation & Methodology
Li, H., & Boulanger, P. (2020). A survey of heart anomaly detection using ambulatory electrocardiogram (ECG). Sensors, 20(5), 1461. https://doi.org/10.3390/s20051461
SummaryThis review examines how ambulatory ECG systems detect abnormal heartbeats and rhythms. It discusses Astroskin as an example of a garment that could combine ECG with movement and breathing signals when investigating motion artifacts.
Key FindingThe review identifies motion artifacts and scarce labeled examples of abnormal rhythms as obstacles to automated ECG analysis. It does not report accuracy for an Astroskin arrhythmia detector.
Li, H., & Boulanger, P. (2021). An automatic method to reduce baseline wander and motion artifacts on ambulatory electrocardiogram signals. Sensors, 21(24), 8169. https://doi.org/10.3390/s21248169
SummaryThis single-participant methods study evaluated an automatic algorithm for reducing baseline wander and motion artifacts in ambulatory electrocardiogram recordings. Astroskin and VIVALNK devices recorded lead II ECG and accelerometer signals during daily activities; the methods report one hour per device, while the results later state eight hours of acquisition. The pipeline classified usable 10-second segments, combined ECG-derived noise with accelerometer data, and selected examples showed lower mean squared error across the shown examples and higher correlation in most examples than the comparison algorithms. The findings are preliminary because only the author's data were tested, and the method could not fully reconstruct P and T waves when noise contaminated them.
Key FindingOn selected ECG segments from one participant monitored with Astroskin and VIVALNK, the proposed method had lower mean squared error than the comparison algorithms and higher correlation on most examples; processing across more than 600 ten-second segments averaged 1.5201 seconds per segment. The evaluation used recordings from one healthy 32-year-old man, so larger testing in healthy people and cardiac patients is still needed.
Horvath, Z., & Nagy, D. (2021). New COVID protocol for elite athletes to returning to sport. In 2021 14th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI) (pp. 1–6). IEEE. https://doi.org/10.1109/CISP-BMEI53629.2021.9624364
Hunt, M. G., Rushton, J., Shenberger, E., & Murayama, S. (2018). Positive effects of diaphragmatic breathing on physiological stress reactivity in varsity athletes. Journal of Clinical Sport Psychology, 12(1), 27–38. https://doi.org/10.1123/jcsp.2016-0041
SummaryThis randomized laboratory study enrolled 76 varsity athletes and compared deep diaphragmatic breathing with progressive muscle relaxation after a common paced-breathing phase. Fitted Hexoskin Biometric Shirts captured ECG, respiration rate, tidal volume, heart rate, and RR intervals across baseline, intervention, and a later cognitive stress task. During the intervention, diaphragmatic breathing produced lower respiration rate, higher tidal volume, lower heart rate, and higher heart rate variability than progressive muscle relaxation; compared with paced breathing, it changed respiration rate and tidal volume but not heart rate or heart rate variability. The group differences did not persist during the cognitive challenge, and interpretation is limited by the absence of an inactive control, the single-session design, baseline heart rate variability imbalance, and unmatched breathing rates.
Key FindingIn varsity athletes monitored with Hexoskin, diaphragmatic breathing produced a lower breathing rate and higher tidal volume than paced breathing and produced lower heart rate and higher heart rate variability than progressive muscle relaxation during the intervention. These immediate differences did not carry into the cognitive stress task 10 minutes later, so the study does not establish a lasting stress-response benefit.
Hunt, M., Rajagopal, T., Cerecino, F., & O’Neil, M. (2021). Mindful versus diaphragmatic breathing: Spirituality moderates the impact on heart rate variability. Mindfulness, 12(11), 2743–2753. https://doi.org/10.1007/s12671-021-01738-x
SummaryThis randomized study assigned 48 University of Pennsylvania undergraduates to video-guided mindful breathing or diaphragmatic breathing. Hexoskin recordings provided respiration rate, tidal volume, continuous ECG, RR intervals, and SDNN heart rate variability at baseline, during the intervention, and at a one-week follow-up. Both groups reduced respiration rate and increased tidal volume, but only the diaphragmatic-breathing group showed significant heart rate variability increases during the video and at follow-up. Seven participants did not return, technical failures caused missing data, and the small selective sample and brief intervention limit generalizability.
Key FindingIn undergraduates monitored with Hexoskin, diaphragmatic breathing increased heart rate variability from baseline, while mindful breathing did not reach statistical significance; the between-group difference was present during the video but absent one week later. A spirituality-by-condition interaction was only marginally significant at p = 0.06, so the proposed moderating role of spirituality remains tentative.
A Middleman Application for Cross-Platform Data Collection from Hexoskin Smart Vest
Bonakdar, K. (2025). A middleman application for cross-platform data collection from Hexoskin smart vest [Master’s thesis, California State University, Northridge].
SummaryThis master's thesis developed the Boracle Middleman mobile application to collect, standardize, and store data from wearable devices. Hexoskin served as the direct Bluetooth Low Energy testbed on Android, streaming heart rate, respiration rate, step count, activity level, and cadence to local logs and a Firebase-backed pipeline. Tests covered 1-, 5-, and 15-minute sessions and separate five-minute sitting, walking, and jogging trials; log, local, and Firebase records matched, with no data loss observed. The work validates prototype data transport and storage under controlled developer testing, without a clinical cohort, physiological-accuracy comparison, completed iOS Hexoskin integration, or long-duration field validation.
Key FindingThe Android prototype maintained stable Hexoskin Bluetooth communication and one-to-one agreement among live logs, local storage, and Firebase during the reported short tests. These results support the software pipeline's data-preservation function, but they do not validate the physiological accuracy of the Hexoskin measurements or clinical performance.
Data channels
ActivityBreathing RateCadenceHeart RateSteps
HexoskinArticleNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Ichiba, T., Kawamura, A., Nagao, K., Kurumai, Y., Fujii, A., Yoshimura, A., Yoshiike, T., & Kuriyama, K. (2022). Periocular skin warming promotes sleep onset through heat dissipation from distal skin in patients with insomnia disorder. Frontiers in Psychiatry, 13, 844958. https://doi.org/10.3389/fpsyt.2022.844958
SummaryThis single-blind crossover study analyzed 38 adults with sleep difficulty or insomnia disorder after one of 39 enrolled participants withdrew at baseline. Participants completed a two-day baseline and two seven-night home intervention periods using warming and sham eye masks, with separate portable EEG and iButton skin-temperature measurements and Hexoskin ECG-derived heart rate variability. Warming shortened objective sleep-onset latency relative to sham, while foot-proximal temperature gradient and normalized high-frequency heart rate variability increased relative to baseline. Foot-proximal temperature gradient was associated with objective sleep-onset latency, but the regression explained only 4.6% of its variance and did not retain the heart rate variability measures. The 8.5-minute reduction was below the cited 10-minute clinical-significance threshold, and interpretation is limited by the single-blind home design, portable EEG definition, and Kao Corporation funding.
Key FindingPeriocular warming shortened EEG-measured sleep-onset latency by 8.5 minutes relative to sham, below the cited 10-minute clinical-significance threshold. The foot-proximal skin-temperature gradient was associated with objective sleep-onset latency (R²=0.046); Hexoskin-derived normalized high-frequency heart rate variability increased relative to baseline but was not retained in the final regression model.
Mouzoune, I. (2018). Validité de critère du textile intelligent Hexoskin pour évaluer la fonction cardiorespiratoire chez une population en santé [Mémoire de maîtrise, Université de Sherbrooke]. https://hdl.handle.net/11143/12266
SummaryThis master’s thesis compared Hexoskin with a Cosmed reference system during treadmill exercise in healthy, physically active adults. The maximal exercise analysis included 28 participants, and 27 contributed to the submaximal analysis. During maximal exercise, heart rate and respiratory rate correlated strongly with the reference, while estimated ventilation correlated weakly.
Key FindingDuring maximal treadmill exercise, correlations between Hexoskin and Cosmed ranged from 0.97 to 0.99 for heart rate and 0.89 to 0.99 for respiratory rate, but only 0.16 to 0.37 for ventilation. The results distinguish tracking breathing frequency from estimating the volume of air moved.
Ingraham, K. A., Ferris, D. P., & Remy, C. D. (2019). Evaluating physiological signal salience for estimating metabolic energy cost from wearable sensors. Journal of Applied Physiology, 126(3), 717–729. https://doi.org/10.1152/japplphysiol.00714.2018
Olschewski, M. (2025). Machine learning-based metabolic rate estimation from wearable sensors [Bachelor’s thesis, University of Stuttgart]. https://doi.org/10.18419/opus-16447
SummaryOlschewski reanalysed a dataset from ten healthy adults to compare machine-learning approaches for estimating energy expenditure. One feature configuration, labelled “Hexoskin,” combined waist acceleration, heart rate, breathing frequency, and minute ventilation measured in the underlying multi-device dataset. Random Forest performed best for that configuration when testing on a held-out participant, while a multilayer perceptron performed best when testing on a held-out task. The thesis explores a sensor configuration rather than establishing the accuracy of recordings from a Hexoskin garment, and its limited tuning and preprocessing choices constrain interpretation.
Key FindingFor the feature subset labelled “Hexoskin,” the lowest reported RMSE was 1.26 with Random Forest in leave-one-subject-out testing and 1.35 with a multilayer perceptron in leave-one-task-out testing. These results concern a reanalysed sensor configuration and should not be presented as a direct validation of Hexoskin hardware.
HexoskinConference AbstractCardiology & ArrhythmiaRespiratory & Infectious DiseaseClinical Medicine & Surgery
Ismail, I., Rand, C., Krishnamurthi, N., & Weese-Mayer, D. E. (2025). Heart rate variability measurement through a smart wearable device in congenital central hypoventilation syndrome (CCHS): Influence of PHOX2B genotype. American Journal of Respiratory and Critical Care Medicine, 211(Supplement 1), A4429. https://doi.org/10.1164/ajrccm.2025.211.Abstracts.A4429
Raw signals
ECG
HexoskinAcademic ThesisClinical Medicine & SurgeryCardiology & Arrhythmia
Étude fondamentale d’un protocole ostéopathique viscéral péricardique sur la physiologie cardiaque
Fatisson, J. (2018). Étude fondamentale d’un protocole ostéopathique viscéral péricardique sur la physiologie cardiaque [Mémoire de recherche, Collège d’Études Ostéopathiques].
SummaryFatisson investigated changes in heart rate variability around a pericardial osteopathic protocol in healthy adults. The study compared an intervention group with placebo and no-touch groups over four weekly appointments. Hexoskin recorded ECG-derived data for analysis in Kubios-HRV, alongside quality-of-life and mood questionnaires. Exploratory subgroup findings varied with initial LF/HF levels and do not establish a clinical treatment benefit.
Key FindingThe thesis used repeated wearable ECG measurements to examine physiological responses around manual therapy. Its exploratory subgroup findings require clinical validation and should not be presented as evidence that the protocol treats disease.
Pion-Massicotte, J., Godbout, R., Savard, P., & Roy, J.-F. (2019). Development and validation of an algorithm for the study of sleep using a biometric shirt in young healthy adults. Journal of Sleep Research, 28(2), e12667. https://doi.org/10.1111/jsr.12667
SummaryPion-Massicotte and colleagues developed a sleep-classification algorithm using ECG, respiratory movement, and accelerometry recorded with Hexoskin. Young healthy adults were monitored for two consecutive nights in a sleep laboratory alongside polysomnography. The corrected algorithm was evaluated on 35 recordings and achieved 77.4% agreement for wake, NREM, and REM classification. The study supports further investigation in healthy young sleepers; participant counts differ between the abstract and Methods, and the results should not be extrapolated to sleep disorders.
Key FindingAdding sleep-onset and sleep-offset corrections to a model using Hexoskin recordings increased three-state agreement with polysomnography from 70.2% to 77.4%; sleep/wake agreement reached 90.8%. The authors caution that findings from healthy young sleepers cannot be generalized to pathological conditions.
Raw signals
AccelerationECGRespiration
Data channels
ActivityBreathing RateHeart RateSleep Stages
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human FactorsValidation & Methodology
Jain, S., Barua Chowdhury, B. D., Mosier, J. M., Subbian, V., Hughes, K., & Son, Y.-J. (2025). Design and development of an integrated virtual reality (VR)-based training system for difficult airway management. IEEE Journal of Translational Engineering in Health and Medicine, 13, 49–60. https://doi.org/10.1109/JTEHM.2025.3529748
SummaryJain and colleagues developed a virtual-reality airway-training system that combined physical airway models and procedural sensors with a Hexoskin vest. Ten subjects took part in positional calibration, and seven clinicians evaluated realism and usability. The paper reports calibration and survey results but gives no physiological measurements from the vest.
Key FindingSeven clinicians evaluated the realism and usability of a virtual-reality airway-training system that included a Hexoskin vest. The paper reports participant feedback and system calibration, but no physiological results from the vest.
Janani Priyanka, P. R., Cheriyan, D., & Choi, J.-H. (2022). A proactive approach to execute targeted particulate matter control measures for construction works. Journal of Cleaner Production, 368, 133168. https://doi.org/10.1016/j.jclepro.2022.133168
SummaryPriyanka and colleagues studied how dust exposure varies across construction activities and materials in a laboratory chamber. Optical particle counters measured PM1, PM2.5, and PM10 at two heights, while Hexoskin supplied inhalation-rate data for a hypothetical worker risk assessment. The results informed proposed locations for dust-control measures based on the activity and the areas of highest exposure. Field testing and assessment before and after installing those controls remain future work.
Key FindingCombining dust concentration with inhalation rate allowed the authors to model exposure for a worker in a high-exposure zone. Hexoskin contributed respiratory input to the model; it did not measure particulate matter, and the study did not test clinical health outcomes.
HexoskinAcademic ThesisOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Kutzin, J. M. (2025). The Impact of Light on Healthcare Professionals' Stress Levels Following a Simulated Clinical Experience. Texas Woman's University, College of Nursing (doctoral dissertation). https://hdl.handle.net/11274/17133
SummaryEmergency-department clinicians wore Hexoskin before, during, and after a simulated clinical event in a randomized comparison of blue and fluorescent debriefing light. The available thesis evidence reports a simulation-related stress response but no statistically significant difference between lighting groups in stress level or recovery duration.
Key FindingBlue debriefing light did not produce a statistically significant stress-recovery advantage over fluorescent light in the available results.
Jayasekera, S., Hensel, E., & Robinson, R. (2021). Feasibility assessment of wearable respiratory monitors for ambulatory inhalation topography. International Journal of Environmental Research and Public Health, 18(6), Article 2990. https://doi.org/10.3390/ijerph18062990
SummaryResearchers compared wearable respiratory monitors against six criteria for measuring how people inhale outside the laboratory. Hexoskin ranked highest among the devices reviewed. Even so, none met all six criteria without modification.
Key FindingHexoskin ranked as the most suitable wearable reviewed, but no available monitor met all six requirements for ambulatory inhalation topography without further development.
Jayasekera, S., Hensel, E., & Robinson, R. (2021). Feasibility of Using the Hexoskin Smart Garment for Natural Environment Observation of Respiration Topography. Preprints (www.preprints.org). https://doi.org/10.20944/preprints202105.0462.v1
SummaryTen adult tobacco users enrolled in a three-day study of cigarette or hookah use in daily life. The researchers calibrated Hexoskin respiratory bands against a spirometer each day. Seven participants completed the study, yielding 4,733 breathing cycles for analysis of inhaled volume, flow and timing.
Jayasekera, S., Hensel, E. C., Jr., & Robinson, R. J. (2023). Benchtop characterization of wearable respiratory monitors for assessing feasibility of measuring lung volume. ASME Open Journal of Engineering, 2, Article 021046. https://doi.org/10.1115/1.4063340
SummaryResearchers tested Hexoskin and two other wearable respiratory monitors on a mechanical chest simulator. Over five repeated trials, the Hexoskin abdominal band produced the most linear response to chest expansion. Its signal also showed virtually no decay during simulated breath holds.
Key FindingHexoskin showed the strongest linearity and breath-hold stability among the three wearable respiratory monitors tested on the benchtop simulator.
Ben Jebara, S., Ouakrim, Y., Dixon, P. C., & Mezghani, N. (2024). On the Use of Hidden Markovian Model to Detect Cough from Respiratory Signals. 2024 IEEE 12th International Symposium on Signal, Image, Video and Communications (ISIVC). https://doi.org/10.1109/ISIVC61350.2024.10577891
Raw signals
AccelerationRespiration
AstroskinConference PaperOccupational Health & Human FactorsData Science & Artificial Intelligence
SummaryResearchers illustrated a proposed framework for assessing astronaut countermeasures with data from 90 firefighter students in cold-stress training. The students wore Hexoskin shirts; Astroskin Bio-Monitor was discussed as a possible spaceflight application.
Key FindingThe case study shows how physiological data could inform individualized monitoring. It reports no astronaut cohort and does not test Astroskin performance in space.
Jlassi, O., Hadid, A., McDonald, E. G., Ding, Q., Phillipp, C., Trottier, A., Cheng, M. P., Papenburg, J., Libman, M., Jensen, D., & Dixon, P. C. (2026). Predicting viral respiratory tract infections using wearable biosensor monitoring during 3-minute constant rate stair stepping tests. Frontiers in Sensors. https://doi.org/10.3389/fsens.2026.1736869
SummaryIn a 12-day influenza-challenge study, 55 healthy adults wore Hexoskin or Astroskin garments during repeated three-minute stair tests and two-minute recoveries. A model using heart-rate variability during recovery predicted a blood-biomarker immune-response score with an area under the ROC curve of 0.73. Models based on measurements taken during activity performed less well.
Key FindingRecovery heart-rate variability from Hexoskin and Astroskin produced the study's strongest immune-response model, with AUC 0.73.
Pion-Massicotte, J. (2014). Mise au point et validation d'un algorithme pour caractériser le sommeil à l'aide du vêtement intelligent Hexoskin. École Polytechnique de Montréal, Université de Montréal (mémoire de maîtrise, Institut de génie biomédical). https://publications.polymtl.ca/1589
SummaryThis master’s thesis tested whether a classifier using Hexoskin recordings could distinguish wakefulness, non-REM sleep and REM sleep against polysomnography. Twenty-one healthy young adults participated in a two-night protocol; excluding one participant’s recordings left 40 nights for analysis. The best corrected classifier reached mean agreement of 77.54%, with a mean kappa of 0.54.
Key FindingAcross 40 nights in healthy young adults, the Hexoskin-based classifier had mean agreement of 77.54% with polysomnography for wake, non-REM and REM sleep. Mean kappa was 0.54, indicating moderate agreement beyond chance.
Raw signals
AccelerationECGRespiration
Data channels
Breathing RateHeart RateSleep Stages
AstroskinHexoskinConference PaperOccupational Health & Human FactorsCardiology & ArrhythmiaNeuroscience, Sleep & Cognition
The Astroskin, a Wearable Body Metrics Garment to Measure Physiological Parameters in Non-Clinical Environments: Health and Spaceflight Missions Applications
Robillard, C., Roy, J. F., Fournier, P. A., Dubeau, S., Gagné-Turcotte, A., Robillard, M. È., & Pion-Massicotte, J. (2014, June). The Astroskin, a Wearable Body Metrics Garment to Measure Physiological Parameters in Non-Clinical Environments: Health and Spaceflight Missions Applications. ISGP Annual Meeting, Waterloo, Ontario, Canada.
SummaryRobillard and colleagues described Astroskin’s design for monitoring physiology outside the laboratory. During the XPAntarctik expedition, four users wore the garment for a reported total of 27 days. Power constraints limited recording to selected times.
Key FindingAll four expedition users reported no major discomfort and found the garment easy to use. The field test assessed prolonged wear and usability; it did not establish measurement accuracy or continuous recording for 27 days.
Shen, H., Hao, M., Ren, J., An, Z., & Long, Z. (2024). Experimental study on human HRV under different ventilation conditions in aircraft cockpit. In CSAA/IET International Conference on Aircraft Utility Systems (AUS 2024) (IET Conference Proceedings, Vol. 2024, No. 13, pp. 489-493). IET. https://doi.org/10.1049/icp.2024.2938
Data channels
Heart Rate
HexoskinArticleValidation & MethodologyOccupational Health & Human Factors
Joseph, M. N., Chang, J., Buck, S. G., Auerbach, M. A., Wong, A. H., Beardsley, T. D., Reeves, P. M., Ray, J. M., & Evans, L. V. (2021). A novel application of the modified Angoff method to rate case difficulty in simulation-based research. Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare, 16(6), e142–e150. https://doi.org/10.1097/sih.0000000000000530
SummaryTwenty-five emergency medicine residents wore Hexoskin during clinical simulations. Researchers calculated heart-rate variability from the ECG and compared the residents’ responses with difficulty ratings from five experts. The experts rated scenario difficulty consistently, but their ratings did not predict the residents’ physiological responses.
Key FindingIn simulations that used Hexoskin ECG to assess residents’ cardiac responses, modified Angoff ratings showed strong panel reliability but did not predict residents' heart rate variability changes during simulation.
Raw signals
ECG
Data channels
RR Interval
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & SurgeryCardiology & Arrhythmia
Joseph, M., Ray, J. M., Chang, J., Cramer, L. D., Bonz, J. W., Yang, T. J., Wong, A. H., Auerbach, M. A., & Evans, L. V. (2022). All clinical stressors are not created equal: Differential task stress in a simulated clinical environment. AEM Education and Training, 6(2), Article e10726. https://doi.org/10.1002/aet2.10726
SummaryTwenty-seven emergency medicine residents wore Hexoskin during six simulated encounters involving medical difficulty, equipment failure or interpersonal conflict. Residents reported different levels of distress depending on the stressor. Heart-rate variability fell from resting levels with all three stressors, but the differences between stressors were not significant.
Key FindingIn emergency medicine residents monitored with Hexoskin, different simulation stressors produced different distress responses, but all were associated with similar reductions in heart rate variability from rest.
Munsterhuis, K. A. K. O. (2022). De detectie van slikbewegingen met de Hexoskin longvolumesensor na inname van voedsel met verschillende structuur. Bachelor thesis, Biomedische Technologie, Universiteit Twente. https://essay.utwente.nl/93158/1/KoekkoekopMunsterhuis_BA-TNW.pdf
SummaryTen volunteers wore Hexoskin while swallowing water, custard, apple, bread, and saliva so that thoracic and abdominal respiratory signals could be compared with video-annotated swallow timing. Swallows after food intake were distinguishable from normal breathing, but the study did not identify a universal respiratory pattern that separated all food structures.
Key FindingHexoskin respiratory signals supported swallow-event detection, while reliable classification of food structure remained unresolved.
Raw signals
Respiration
HexoskinConference PaperValidation & MethodologyOccupational Health & Human Factors
Kamakura, Y., Takeuchi, H., & Ohsuga, M. (2021). Contactless and Low-Burden Measurement of Physiological Signals and Comparison of Obtained Indices. IEA 2021, LNNS 222. https://doi.org/10.1007/978-3-030-74611-7_83
K., S. A. K., Girard, B., & Menelas, B. A. J. (2020). Dynamic Difficulty Adjustment Through Real-Time Physiological Feedback for a More Adapted Virtual Reality Exposure Therapy. Games and Learning Alliance, 9th International Conference, GALA 2020, Laval, France, Proceedings; Lecture Notes in Computer Science 12517 (Springer). https://doi.org/10.1007/978-3-030-63464-3_10
Data channels
Heart Rate
HexoskinArticleOccupational Health & Human FactorsCardiology & Arrhythmia
Kato, K., Hashimoto, Y., Aimoto, K., Kamiya, M., Kawamura, K., Yoshimi, T., & Kondo, I. (2025). Electrocardiogram and respiration recordings show a reduction in the physical burden on professional caregivers when performing care tasks with a transfer support robot. Assistive Technology, 37(3), 185–193. https://doi.org/10.1080/10400435.2024.2409289
SummaryEighteen professional caregivers performed transfer tasks using a wheelchair and a transfer-support robot while Hexoskin recorded ECG and respiration. After robot-assisted transfers, caregivers had lower heart rates and reported less physical stress. Heart-rate variability and cardiorespiratory coherence were generally higher with the robot.
Key FindingIn caregivers whose ECG and respiration were recorded with Hexoskin, using the transfer-support robot reduced several physiological and perceived indicators of caregiver physical burden compared with wheelchair transfers.
Raw signals
ECGRespiration
Data channels
Heart Rate
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & Surgery
Khan, I. A., Haffar, A., Magnuson, J. A., Ong, C., Austin, M. S., Krueger, C. A., & Lonner, J. H. (2022). Surgeons experience greater cardiorespiratory strain and stress during total hip arthroplasty than total knee arthroplasty. The Journal of Arthroplasty, 37(4), 637–641. https://doi.org/10.1016/j.arth.2021.12.007
SummaryThe methods and results describe two surgeons who wore Hexoskin during 76 consecutive hip and knee replacements. The researchers compared physiological demand across the two operations. Hip replacement was associated with higher surgeon heart rate, minute ventilation and energy expenditure per unit time than knee replacement.
Key FindingTwo arthroplasty surgeons monitored with Hexoskin experienced greater cardiorespiratory strain during total hip arthroplasty than during total knee arthroplasty.
Khan, I. A., Baker, C. M., Magnuson, J. A., Courtney, P. M., Krueger, C. A., & Lonner, J. H. (2023). Surgeons experience more physiologic stress and strain during revision than primary total joint arthroplasty. The Journal of Arthroplasty, 38(6), 1126–1130. https://doi.org/10.1016/j.arth.2022.12.022
SummaryTwo surgeons wore Hexoskin during 70 primary and revision joint replacements. Revision procedures took longer and were associated with higher surgeon heart rate, stress index and energy expenditure. Heart-rate variability was lower during revisions than during primary procedures.
Key FindingThe two surgeons monitored with Hexoskin showed greater physiological demand during revision joint replacements than during primary joint replacements.
Khan, M. N. H., Creswell, D., Albert, J., O'Connell, P., Fallon, S., Polowitz, M., Xu, X., & Islam, B. (2025). Mindfulness meditation and respiration: Accelerometer-based respiration rate and mindfulness progress estimation to enhance app engagement and mindfulness skills. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, 9(3), Article 95. https://doi.org/10.1145/3749498
SummaryResearchers used Hexoskin as the respiratory reference for a smartphone system designed to track breathing and progress in mindfulness practice. The smartphone’s respiration estimate differed from the reference by an average absolute error of 1.6 breaths per minute. In a separate analysis, classifiers of mindfulness skill achieved F1 scores of 80% to 84%.
Key FindingThe smartphone’s respiratory-rate estimates had a mean absolute error of 1.6 breaths per minute against Hexoskin. A separate analysis classified three mindfulness skills.
Raw signals
Respiration
Data channels
Breathing Rate
HexoskinAcademic ThesisOccupational Health & Human FactorsCardiology & Arrhythmia
Vyas, K. (2019). Firefighter Resilience Assessment Using a Structured Approach. Ontario Tech University (Master of Health Science in Health Informatics thesis). https://hdl.handle.net/10155/1131
SummaryFifty pre-service firefighters completed baseline and simulated search-and-rescue monitoring with Hexoskin after six additional recruits lost data to garment or battery problems. Women showed higher SDNN and lower mean heart rate than men, but the small female subgroup limits interpretation of the reported sex differences.
Key FindingHexoskin heart-rate variability measures were incorporated into a structured firefighter resilience assessment during simulated operational training.
Klingenberg, A., Purrucker, V., Schüler, W., Ganapathy, N., Spicher, N., & Deserno, T. M. (2022). Human activity recognition from textile electrocardiograms. 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). https://doi.org/10.1109/EMBC48229.2022.9871210
Koshy, A., Čironis, L., McVey, M., Sousa, A., Ahmad, S. L., Hassan, T., Yuen, K., Douris, P., Zwibel, H., & DiFrancisco-Donoghue, J. (2020). An observation of common physiological parameters during esports activity. International Journal of Esports. https://www.ijesports.org/article/29/html
SummaryNineteen male university esports players enrolled in a study of physiological responses during League of Legends or Overwatch sessions lasting 1.5 to 2.5 hours. Seventeen provided usable Hexoskin recordings. Heart rate, breathing rate and minute ventilation changed significantly from rest; in League of Legends, the winning team had higher values than the losing team.
Key FindingHexoskin recorded significant cardiac and respiratory changes during competitive esports play in 17 analyzed players.
Raw signals
ECGRespiration
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinConference PaperOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Krätzig, G. P., Hembroff, C. C., & Ahlgrim, B. (2021). Comparison Study of Attention Between Training in a Simulator vs. Live-Fire Range. HCII 2021, LNAI 12776 (D. D. Schmorrow and C. M. Fidopiastis, Eds.), Springer Nature. https://doi.org/10.1007/978-3-030-78114-9_13
Krause, R., van Bavel, J. J. A., Wu, C., Vos, M. A., Nogaret, A., & Indiveri, G. (2021). Robust neuromorphic coupled oscillators for adaptive pacemakers. Scientific Reports, 11(1), 18073. https://doi.org/10.1038/s41598-021-97314-3
SummaryResearchers used surface ECG and respiratory recordings from three dogs wearing Hexoskin to develop and test a neuromorphic pacemaker model. The hardware reproduced the target cardiac timing with an average oscillation period of 556 milliseconds. Its pacing also varied with respiratory phase.
Key FindingHexoskin recordings provided the physiological reference used to demonstrate respiration-adaptive timing in a low-power neuromorphic pacemaker model.
Krishnapriya, G. B., Ponnalagu, R. N., & Goel, S. (2025). A Resource-Efficient Time-Domain-Based Algorithm to Estimate Respiration Rate From Single-Lead ECG Signal. IEEE Open Journal of Instrumentation and Measurement. https://doi.org/10.1109/OJIM.2025.3548816
SummaryResearchers tested an algorithm that estimates respiration from ECG using a public benchmark recorded with Hexoskin Hx1 in 13 people. They tested real-time operation separately in five people using a different sensor. On the Hexoskin benchmark, the mean absolute error was 3.66 breaths per minute and the mean absolute percentage error was 23.69%.
Key FindingA public Hexoskin Hx1 dataset served as the benchmark for an ECG-derived respiration algorithm with 3.66 breaths-per-minute mean absolute error.
Krüger, A. (2025). Stabilität von Atemmustern im Biathlonschießen und deren Einfluss auf die Trefferleistung unter varianter physischer Belastung. Universität Salzburg, Natur- und Lebenswissenschaftliche Fakultät, Fachbereich für Sport- und Bewegungswissenschaft (Masterarbeit). https://eplus.uni-salzburg.at/Abschlussarbeiten/content/titleinfo/11808009
SummaryNine junior and 11 professional biathletes wore Hexoskin during roller-ski shooting sessions under increasing physical load. Breathing-pattern stability predicted prone shooting accuracy, while an inhaled pattern at shot release was associated with lower standing accuracy, particularly among junior athletes.
Key FindingBreathing stability was linked to prone shooting success, and inhaling at standing shot release was associated with poorer accuracy.
Raw signals
AccelerationRespiration
AstroskinPoster / PresentationValidation & MethodologyOccupational Health & Human Factors
Kumar, A., Levin, E., Cowings, P., & Toscano, W. B. (2015). Evaluation of the accuracy of Astroskin as a behavioral health self-monitoring system for spaceflight [Poster presentation]. Annual Summer STEM Internship Symposium, Salinas, CA, United States. https://ntrs.nasa.gov/citations/20150021842
SummaryFour adults took part in a rotating-chair motion-sickness experiment on the ground. Researchers compared Astroskin heart and breathing rates with a Flexcomp system and its blood-pressure estimates with Finapres finger measurements.
Key FindingHeart rate averaged over 15-second blocks correlated strongly with Flexcomp (r = 0.989). Breathing-rate correlation was lower (r = 0.709), and Finapres blood-pressure readings were significantly higher than Astroskin estimates.
Kuznetsov, M., Grant, A. R., Coden, G., Travers, H. I., & Talmo, C. (2025). Radiographic femur girth ratio- not body mass index, predicts surgical energy expenditure in total knee arthroplasty. Journal of Orthopaedic Reports, 4(1), 100582. https://doi.org/10.1016/j.jorep.2025.100582
SummaryOne surgeon wore Hexoskin during 185 primary total knee replacements. A higher radiographic knee-girth ratio predicted higher surgeon heart rate, total energy expenditure and energy expenditure per minute. Patient body mass index did not correlate with the surgeon’s energy consumption.
Key FindingRadiographic knee-girth ratio predicted the surgeon’s energy demand measured with Hexoskin more effectively than patient body mass index.
Lambert, E. L., Nguyen, J. D., Noronha, S. J., Rodriguez, M. J., Saint-Fleur, M. A., Sebacher, K. L., & Travis, J. C. (2020). A feasibility assessment and analysis of alternatives of wearable and non-wearable cockpit biometrics aboard fighter class aircraft. Naval Postgraduate School, Systems Engineering Capstone Report. https://hdl.handle.net/10945/64918
Lamrani, Y., St-Jean, J., Toffa, D., Nguyen, D. K., & Bou Assi, E. (2021). Classification of interictal and ictal epileptic brain states based on respiratory data acquired with a smart wear. In 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) (p. 5205). IEEE. https://paperhost.org/proceedings/embs/EMBC21/files/2428.pdf
SummaryResearchers tested whether breathing patterns recorded with a Hexoskin shirt could distinguish seizures from periods between seizures. An epilepsy specialist used video EEG to mark seizure onset and offset without seeing the shirt data. Across 67 seizures in 13 patients, both breathing rate and minute ventilation differed between seizure and nonseizure periods (p < 0.01).
Key FindingAmong four classifiers tested on Hexoskin respiratory recordings from 13 patients, a support vector machine best distinguished seizure from nonseizure periods, averaging 76.7% accuracy.
Lamrani, Y., Tran, T. P. Y., Toffa, D. H., Robert, M., Bérubé, A. A., Nguyen, D. K., & Bou Assi, E. (2023). Unexpected cardiorespiratory findings postictally and at rest weeks prior to SUDEP. Frontiers in Neurology, 14, 1129395. https://doi.org/10.3389/fneur.2023.1129395
SummaryOne patient who later died from sudden unexpected death in epilepsy and two living controls wore Hexoskin during epilepsy monitoring. Weeks before the death, one seizure was followed by prolonged shallow breathing and a slow heart rate; most other recorded seizures were unremarkable. Separate heart-rate-variability analyses used the video-EEG system.
Key FindingHexoskin monitoring identified an unusual prolonged postictal cardiorespiratory disturbance weeks before sudden unexpected death in epilepsy in this single-patient report.
Data channels
Breathing RateHeart Rate
HexoskinArticleOccupational Health & Human FactorsValidation & Methodology
Landau, K., & Nadeau, S. (2020). Comparison of Different Parameters of Heart Rate Frequency of Tasks Performed during Aircraft Open-Basket Ground Deicing Activities. Ergonomics International Journal, 4(6), 1–13. https://doi.org/10.23880/eoij-16000260
SummaryTwelve aircraft ground-deicing technicians wore Hexoskin during open-basket field work. The shirt updated heart rate every second, and 11 operators provided data suitable for analysis. Heart-rate-reserve and age-adjusted thresholds classified strain as excessive more often than the working-heart-rate method.
Key FindingUsing heart rate recorded with Hexoskin in aircraft deicing technicians, heart-rate-reserve and age-adjusted approaches detected more threshold exceedances than working heart rate during open-basket deicing work.
Landry, C., Hedge, E. T., Hughson, R. L., Peterson, S. D., & Arami, A. (2020). Cuffless Blood Pressure Estimation for Activities of Daily Living. 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). https://doi.org/10.1109/embc44109.2020.9175976
SummaryCan wearable signals estimate blood pressure during daily activities? In three participants, researchers trained personalized models using Astroskin ECG, forehead photoplethysmography and acceleration to estimate systolic and diastolic pressure. They evaluated the estimates separately for each participant.
Key FindingWith the Train1 setup, mean absolute error ranged from 6.3 to 11.3 mmHg for systolic pressure and from 5.2 to 9.8 mmHg for diastolic pressure. The lowest errors came from one participant.
Landry, C., Hedge, E. T., Hughson, R. L., Peterson, S. D., & Arami, A. (2021). Accurate Blood Pressure Estimation during Activities of Daily Living: A Wearable Cuffless Solution. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2021.3054597
SummaryThis study developed personalized cuffless blood-pressure models for activities of daily living in five healthy adults. Astroskin supplied ECG, forehead photoplethysmography and acceleration inputs to nonlinear autoregressive neural-network models and comparator pulse-arrival-time models. Estimates were compared with Portapres finger blood pressure during six and a half hours of data collection per participant. Two participants returned about four months later, and one was tested again at six months.
Key FindingAcross participants, blood-pressure models using Astroskin ECG, forehead photoplethysmography and acceleration produced mean absolute error that ranged from 6.21 to 7.58 mmHg for systolic pressure and from 5.03 to 6.16 mmHg for diastolic pressure, depending on the model. All models met the reported AAMI bias requirement, while only selected models met the systolic standard-deviation requirement. The personalized results from five young healthy participants do not establish population-level or clinical performance.
Landry, C., Peterson, S. D., & Arami, A. (2022). A fusion approach to improve accuracy and estimate uncertainty in cuffless blood pressure monitoring. Scientific Reports. https://doi.org/10.1038/s41598-022-12087-7
SummaryThis study evaluated uncertainty-aware fusion of three cuffless blood-pressure models in five healthy participants. Astroskin supplied ECG, PPG, and pulse-arrival-time inputs, while Portapres finger blood pressure served as the reference. Each participant completed 6.5 hours of monitoring. Fusion improved blood-pressure and prediction-interval precision by up to 24%, but the small healthy sample and participant-specific training limit generalizability.
Key FindingCombining blood-pressure estimates from models using Astroskin signals improved blood-pressure and prediction-interval precision by up to 24%; the result was obtained in five healthy participants after participant-specific training.
Raw signals
ECGPPG
Data channels
Pulse Transit Time
HexoskinAcademic ThesisOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
SummaryFifty-nine physicians and nurses in two emergency departments participated in a cluster-randomized sleep and stress management study that used Hexoskin ECG during work shifts. The thesis reports a 9% improvement in work-hour heart-rate variability and about 15 additional minutes of sleep per night in the intervention group, with stronger cardiac effects among caregivers with moderate burnout.
Key FindingA brief sleep and stress intervention was associated with longer sleep and improved shift heart-rate variability among emergency clinicians.
Raw signals
ECG
Data channels
ActivityHeart RateRR Interval
HexoskinConference PaperOccupational Health & Human FactorsExercise Physiology & Sports Science
Le Floch, T., Nadeau, S., Landau, K., & Morency, F. (2018). Aircraft deicing in open baskets: Study of the effects of activities on heart rate variability. GfA Frühjahrskongress 2018, Frankfurt a. M. (64. Kongress der Gesellschaft für Arbeitswissenschaft), Beitrag A.4.4, GfA-Press, Dortmund. https://espace2.etsmtl.ca/id/eprint/16439
Data channels
Heart Rate
Metrics
Resting Heart Rate
HexoskinAcademic ThesisOccupational Health & Human FactorsExercise Physiology & Sports Science
Le Floch, T. (2018). Ergonomie du dégivrage aéronautique en nacelles ouvertes. École de technologie supérieure, Université du Québec (mémoire de maîtrise en génie des risques de santé et de sécurité du travail). https://espace.etsmtl.ca/id/eprint/2149
SummaryTwelve aircraft-deicing technicians wore Hexoskin during 15 hours and 52 minutes of open-basket field recording, with heart rate synchronized to video-coded work tasks. Heart rate exceeded the individual steady-state threshold for a cumulative 39 minutes, and fluid spraying, vehicle and basket movement, and control tasks were among the most demanding activities.
Key FindingTask-synchronized Hexoskin monitoring identified specific open-basket deicing activities associated with elevated cardiac workload.
Lee, R. H. Y., Vukovic, S., Lucci, V. E. M., Lando, J. T., & Claydon, V. E. (2026). Innovative wearable technology for autonomic and sleep monitoring: Examining metric-level signal performance of the Astroskin biometric shirt.. Autonomic Neuroscience, 267, 103464. https://doi.org/10.1016/j.autneu.2026.103464
SummaryResearchers compared Astroskin with reference methods for oxygen saturation, temperature, heart rate, systolic blood pressure, respiration and sleep at home. Several physiological measures showed strong agreement, but systolic blood pressure had low precision. The system detected sleep successfully, yet produced sleep stages in only 41% of attempts.
Key FindingAstroskin showed strong agreement for several ambulatory physiological measures, while blood-pressure precision and sleep-staging availability remained important limitations.
Feasibility of the Hexoskin™ Biometric Shirt Use in a Focused Breathing Study
Lemoine, D., & Birdee, G. (2019). Feasibility of the Hexoskin biometric shirt use in a focused breathing study. 16th Annual TLSAMP Research Conference, Abstract/Poster 1620.
Lewthwaite, H., D'Elia, G., Johnson, S., Gibson, P., Cross, T., & McDonald, V. M. (2023). Feasibility of wearable smart shirt technology for daily life physiology and symptom assessment in COPD. European Respiratory Journal, 62(Suppl. 67), PA1589. https://doi.org/10.1183/13993003.congress-2023.PA1589
Li, D., Liu, J., Lee, S. I., & Xiong, J. (2022). LASense: Pushing the Limits of Fine-grained Activity Sensing Using Acoustic Signals. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, 6(1), 1-27. https://doi.org/10.1145/3517253
SummaryFifteen participants wore Hexoskin as the respiratory reference for LASense, a contact-free acoustic system. At four metres from the smart speaker, LASense had a median error of 0.21 breaths per minute. Errors remained low across several room and noise conditions.
Key FindingHexoskin reference measurements supported validation of contact-free respiration sensing at distances up to six metres.
Li, J., Xu, E. P., Zapetis, S. L., Phanord, C. S., Ye, Z., Farrukh, U., Forbes, E., Trull, T. J., & Stange, J. P. (2025). Ambulatory Physiological State Dynamics Predict Proximal Behavioral Markers of Affect Regulation in Everyday Life. Journal of Psychopathology and Clinical Science, 134(8), 926-934. https://doi.org/10.1037/abn0001030
SummaryNinety-three adults wore Hexoskin for seven days and reported their feelings and behavior throughout the day. Individual models identified six to 13 physiological states per person. Where the states matched interpretable patterns, selected transitions predicted higher negative affect or impulsivity.
Key FindingTransitions among individualized Hexoskin-derived physiological states were associated with near-term changes in negative affect and impulsivity.
Lim, C. C., Lin, S., & Thurston, G. (2018). Evaluating association between air pollution and cardiovascular outcomes using smartphone particle sensors and wearable technologies in children. Environmental Health Perspectives. https://doi.org/10.1289/isesisee.2018.P01.0540
SummaryTen participants completed respiratory-sinus-arrhythmia biofeedback training while a wrist-worn BreathCoach system was evaluated against Hexoskin ECG and respiration. BreathCoach averaged 9.6 milliseconds of inter-beat-interval error and 0.61 seconds of breathing-cycle-duration error, and the adaptive training improved several biofeedback and recovery measures.
Key FindingHexoskin reference data supported validation of wrist-based inter-beat interval and breathing estimates during adaptive biofeedback training.
van Leuteren, R. W. (2016). CHOPIN: Continuous monitoring of respiration with the Hexoskin smart shirt to detect dynamic hyperinflation in COPD patients. University of Twente, Technical Medicine (Medical Sensing and Stimulation), master thesis; Medisch Spectrum Twente, Department of Pulmonology. https://purl.utwente.nl/essays/70888
SummaryA two-phase study compared Hexoskin respiratory inductance signals with conventional lung-function equipment in 31 healthy adults and 11 patients, 10 of whom had COPD. Signal correlations were generally strong, but agreement for detecting dynamic hyperinflation was low, with Cohen kappa values of about 0.2 to 0.3.
Key FindingHexoskin tracked respiratory volume changes well, while reliable dynamic-hyperinflation classification remained limited.
Raw signals
AccelerationECGRespiration
Data channels
Breathing Rate
HexoskinArticleOccupational Health & Human FactorsExercise Physiology & Sports Science
MacEachern, C. B., Esau, T. J., Zaman, Q. U., & Farooque, A. A. (2023). Assessing the effect of machine automation on operator heart and breathing rate during mechanical harvesting of wild blueberries. Smart Agricultural Technology, 4, 100171. https://doi.org/10.1016/j.atech.2023.100171
SummaryTwo wild-blueberry harvester operators wore Hexoskin during manual, semi-automated and fully automated harvesting. Compared with fully manual harvesting, full automation reduced average heart rate by 13.83% in the experienced operator. The corresponding reduction in the newer operator was 19.03%.
Key FindingGreater harvesting automation was associated with lower operator heart rate measured with Hexoskin than fully manual harvesting for both monitored operators.
Data channels
Breathing RateHeart Rate
HexoskinArticleNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Macnamara, A., Coussens, S., Chen, C., Schinazi, V. R., & Loetscher, T. (2022). The psychological impact of instrumental activities of daily living on people with simulated age-related macular degeneration. BJPsych Open, 8(5), e152. https://doi.org/10.1192/bjo.2022.558
SummaryTwenty-four normally sighted adults performed household tasks with normal vision and with simulated age-related macular degeneration. Researchers used Hexoskin to track physiology, time and steps, and also assessed task performance and distress. Simulated impairment slowed task completion, increased anxiety and distress, and reduced engagement, without significant changes in heart rate, heart-rate variability or respiratory rate.
Key FindingIn a household-task study using Hexoskin for physiological monitoring, simulated macular degeneration affected task performance and psychological state without a significant change in the monitored physiological measures.
Raw signals
Acceleration
Data channels
Breathing RateHeart RateRR IntervalSteps
HexoskinConference PaperData Science & Artificial IntelligenceNeuroscience, Sleep & CognitionOccupational Health & Human Factors
MacNeil, E., Bishop, A., & Izzetoglu, K. (2022). Study of Different Classifiers and Multi-modal Sensors in Assessment of Workload. HCII 2022, LNAI 13310 (D. D. Schmorrow and C. M. Fidopiastis, Eds.), Springer Nature. https://doi.org/10.1007/978-3-031-05457-0_13
Raw signals
Respiration
Data channels
Heart Rate
AstroskinArticleOccupational Health & Human FactorsValidation & Methodology
MacQuarrie, A., Stainer, M., Sidhu, J., & Deetlefs, C. (2023). Wearable physiologic monitoring in healthcare simulation. International Journal of Healthcare Simulation. https://doi.org/10.54531/polx6384
SummaryThis short report described wearable physiological monitoring in pilot healthcare-simulation studies with paramedicine students. The team added Astroskin monitoring to its established use of Hexoskin in simulation research. Both shirts streamed to an iPad and uploaded data for dashboard analytics before further analysis. The pilot evaluated deployment and participant comfort rather than data quality. The report did not state a participant count.
Key FindingThe researchers estimated that fitting Astroskin took less than 10 minutes per participant. Participants reported no discomfort while wearing the shirts. Full quantitative validation of Astroskin data quality was deferred to a separate publication.
HexoskinArticleOccupational Health & Human FactorsNeuroscience, Sleep & CognitionExercise Physiology & Sports Science
MacQuarrie, A. S., Hunter, J., Steele, J., Chandramouli, S., Stainer, M., Rengers, A., & Wickham, J. (2025). The effect of occupational physical activity on paramedic student neurocognitive response in high-fidelity simulation: a pilot randomized cross-over trial. Journal of Healthcare Simulation, ITNX9528. https://doi.org/10.54531/itnx9528
SummaryEleven final-year paramedicine students or recent graduates wore Hexoskin during simulations after an occupational carrying task and after seated rest. Heart rate, respiratory rate, movement and perceived exertion were higher after the carrying task. The two neurocognitive tests showed no overall intervention effect.
Key FindingIn a crossover simulation study using Hexoskin to monitor paramedic trainees and recent graduates, occupational activity increased physiological demand and perceived exertion before simulation without a clear overall reduction in neurocognitive test performance.
Raw signals
Acceleration
Data channels
ActivityBreathing RateHeart Rate
HexoskinAcademic ThesisOccupational Health & Human FactorsData Science & Artificial Intelligence
Sudarsan, M. (2020). Using wearable sensors to evaluate material handling operator's fatigue in repetitive activities: A design of experiments approach. Texas State University. https://hdl.handle.net/10877/12265
SummaryThis thesis investigated whether wearable measurements could help estimate perceived exertion during repetitive lifting in a simulated manufacturing setting. The analysis paired Hexoskin measurements with participants’ Borg exertion ratings and considered task duration, interval and distance alongside breathing rate, heart rate, minute ventilation and activity. The researcher fitted separate regression models for male and female participants and compared model fit on training and test data.
Key FindingIn a repetitive lifting experiment, Hexoskin measurements and task characteristics were used to model self-rated exertion separately for male and female participants.
Mannée, D., de Jongh, F., & van Helvoort, H. (2019). Tidal volumes during tasks of daily living measured with a smart shirt. European Respiratory Journal, 54(Suppl. 63), PA2228. https://doi.org/10.1183/13993003.congress-2019.PA2228
Mannée, D., de Jongh, F., & van Helvoort, H. (2021). The Accuracy of Tidal Volume Measured With a Smart Shirt During Tasks of Daily Living in Healthy Subjects: Cross-sectional Study. JMIR Formative Research. https://doi.org/10.2196/30916
Raw signals
Respiration
Data channels
Tidal Volume
HexoskinArticleOccupational Health & Human FactorsExercise Physiology & Sports Science
Mansouri, F., Nia, M. T., Villar, R., Cornish, S. M., & Giesbrecht, G. G. (2024). Upper- vs. Whole-Body Cooling During Exercise with Thermal Protective Clothing in the Heat. Aerospace Medicine and Human Performance, 95(9), 659-666. https://doi.org/10.3357/amhp.6434.2024
SummaryEight participants exercised in protective clothing with no cooling, upper-body cooling or whole-body cooling while Hexoskin monitored heart rate. Both cooling conditions reduced cardiovascular strain, and every participant completed all three exercise bouts with cooling. Without cooling, no participant began the third bout.
Key FindingIn eight participants exercising in protective clothing with Hexoskin monitoring, upper-body and whole-body liquid cooling both reduced heat-related cardiovascular strain and improved exercise completion in protective clothing.
Data channels
Heart Rate
HexoskinArticleOccupational Health & Human FactorsCardiology & ArrhythmiaNeuroscience, Sleep & Cognition
Marcel-Millet, P., Ravier, G., Grospretre, S., Gimenez, P., Freidig, S., & Groslambert, A. (2018). Physiological responses and parasympathetic reactivation in rescue interventions: The effect of the breathing apparatus. Scandinavian Journal of Medicine and Science in Sports (Scand J Med Sci Sports). https://doi.org/10.1111/sms.13291
SummaryThis randomized crossover study compared firefighter workload and recovery under protective clothing alone, self-contained breathing apparatus with the cylinder, and the full breathing apparatus. Thirty-four firefighters participated, and complete physiological data were analyzed for 28. Hexoskin continuously recorded ECG, chest motion and acceleration during a fitness test and three simulated rescue interventions. Heart rate, breathing frequency, movement, heart-rate recovery and heart-rate variability were analyzed.
Key FindingIn simulated rescue work monitored with Hexoskin ECG, the breathing-apparatus conditions increased completion time and perceived exertion and delayed parasympathetic recovery relative to protective clothing alone. Breathing frequency was lower with the full apparatus than in the other conditions, while mean and peak heart rate remained high across interventions. Six participants had a recording failure in one condition, and the simulated protocol does not establish outcomes in real fires.
Raw signals
AccelerationECGRespiration
Data channels
Breathing RateHeart RateRR Interval
Metrics
Heart Rate Recovery
HexoskinArticleOccupational Health & Human FactorsNeuroscience, Sleep & CognitionCardiology & Arrhythmia
Marcel-Millet, P., Groslambert, A., & Ravier, G. (2020). Effects on Firefighters' Nocturnal Cardiac Autonomic Activity and Sleep Quality of On-Call Nights With and Without Simulated Firefighting Interventions. Journal of Occupational and Environmental Medicine (JOEM), Volume 62, Number 11. https://doi.org/10.1097/jom.0000000000002025
SummaryThis crossover field study compared cardiac-autonomic activity and sleep across three nights in firefighters: a home control night, an on-call night without an intervention and an on-call night with a simulated intervention. Thirteen firefighters participated, and 12 were included in the cardiac and sleep analyses. Hexoskin recorded ECG, respiration and movement and supplied nocturnal heart-rate-variability and dashboard sleep measures. The simulated intervention occurred about 96 minutes after bedtime and lasted 4.2 minutes on average.
Key FindingHeart rate measured with Hexoskin was higher and several parasympathetic heart-rate-variability measures were lower during both on-call conditions than during the control night. Total sleep time was shortest on the night with the simulated intervention. The small workplace study relied on wearable-derived sleep measures and one simulated intervention rather than polysomnography or real-fire outcomes.
Raw signals
AccelerationECGRespiration
Data channels
Heart RateRR Interval
Metrics
Sleep EfficiencyTime to Fall AsleepTotal Sleep Time
HexoskinArticleOccupational Health & Human FactorsCardiology & ArrhythmiaNeuroscience, Sleep & Cognition
Marcel-Millet, P., Groslambert, A., Gimenez, P., Grosprêtre, S., & Ravier, G. (2021). Psychophysiological responses of firefighters to day and night rescue interventions. Applied Ergonomics, 95 (2021) 103457. https://doi.org/10.1016/j.apergo.2021.103457
SummaryThis workplace simulation study compared day and night rescue interventions in 16 male firefighters. Hexoskin recorded ECG during an intermittent fitness test and three rescue conditions: daytime sound alarm, nighttime sound alarm and nighttime vibrating alarm. The analysis covered alarm mobilization, intervention workload, heart-rate recovery and post-exercise heart-rate variability. Sessions were separated by three to 14 days.
Key FindingIn simulated rescue interventions monitored with Hexoskin ECG, nighttime sound alarms produced greater heart-rate reactivity than daytime sound alarms, while the vibrating alarm reduced reactivity relative to the nighttime sound alarm. Recovery after the nighttime sound-alarm condition was slower than after the daytime condition on several measures. The findings come from 16 male firefighters in simulated interventions and do not establish outcomes during real emergencies.
Raw signals
ECG
Data channels
Heart Rate
Metrics
HR MaxHeart Rate Recovery
HexoskinArticleValidation & MethodologyOccupational Health & Human FactorsCardiology & Arrhythmia
Marcel-Millet, P., Ravier, G., Esco, M. R., & Groslambert, A. (2020). Does firefighters' physical fitness influence their cardiac parasympathetic reactivation? Analysis with post-exercise heart rate variability and ultra-short-term measures. International Journal of Occupational Safety and Ergonomics (JOSE). https://doi.org/10.1080/10803548.2020.1738689
SummaryThis study examined post-exercise parasympathetic recovery and physical fitness in 24 firefighters. Hexoskin recorded ECG during an intermittent fitness test, three simulated rescue interventions and pre- and post-exercise rest. One-minute post-exercise RMSSD segments were compared with a five-minute criterion window, and firefighters were divided at the median fitness-test velocity. The shirt was a monitoring tool rather than the device under evaluation.
Key FindingIn analyses of recovery from Hexoskin ECG recordings, the sixth one-minute segment showed good-to-excellent agreement with the five-minute criterion across the tested conditions, whereas earlier segments were less consistent. Higher-fitness firefighters completed rescue tasks faster, but post-exercise LnRMSSD did not differ between fitness groups. Results from 24 simulated-rescue participants require confirmation in larger operational cohorts.
Raw signals
ECG
Data channels
Heart RateRR Interval
Metrics
HR AvgHR MaxRMSSD
HexoskinArticleOccupational Health & Human FactorsExercise Physiology & Sports ScienceValidation & Methodology
Marcel-Millet, P., Ravier, G., & Groslambert, A. (2020). Effect of Protective Equipment on Firefighters' External and Internal Workloads During a Simulated Rescue Intervention. Journal of Strength and Conditioning Research. https://pubmed.ncbi.nlm.nih.gov/32187151
SummaryThis randomized within-subject study compared firefighter workload under three protective-equipment conditions in 22 male firefighters. Hexoskin supplied ECG and hip-acceleration data during simulated rescue interventions. Heart-rate-based and perceived-exertion workloads were higher with the cylinder and full breathing apparatus than with protective clothing alone, while acceleration-based workload was lower and post-exercise heart-rate variability did not differ. The simulated all-male study does not establish operational outcomes in real fires.
Key FindingPerceived exertion was the only workload measure that distinguished all three equipment conditions; post-exercise Hexoskin ECG-derived heart-rate variability did not differ, and the results came from simulated rescues in 22 male firefighters.
Raw signals
AccelerationECG
Data channels
Heart Rate
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & SurgeryValidation & Methodology
Marjanovic, N. S., De Simone, A., Jegou, G., & L’Her, E. (2017). A new global and comprehensive model for ICU ventilator performances evaluation. Annals of Intensive Care, 7(1), 68. https://doi.org/10.1186/s13613-017-0285-2
SummaryTwenty intensive-care physicians tested multiple ventilators while Hexoskin tracked heart rate, respiratory rate and changes in thoracic volume. Physiological activation, usability and task performance varied between ventilators. The paper did not report the shirt’s heart-rate results separately.
Key FindingThe multimodal evaluation identified ventilator-specific differences in clinician stress and usability, with Hexoskin contributing cardiorespiratory monitoring.
Data channels
Breathing RateHeart RateTidal Volume
HexoskinReviewOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Marvin, G., Ben Schram, Orr, R., & Canetti, E. F. D. (2023). Occupation-Induced Fatigue and Impacts on Emergency First Responders: A Systematic Review. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph20227055
AstroskinConference AbstractOccupational Health & Human FactorsExercise Physiology & Sports ScienceValidation & Methodology
Mastrandrea, C., Greaves, D., & Hughson, R. (2021). Tracking astronaut physical activity and cardiorespiratory responses with the Bio-Monitor sensor shirt. The FASEB Journal, 35(S1), 02888. https://doi.org/10.1096/fasebj.2021.35.S1.02888
SummaryAstronauts wore the Canadian Space Agency’s Bio-Monitor shirt before launch and aboard the International Space Station. Researchers analyzed ECG quality and used accelerometry to compare time spent in high-force movement on Earth and in orbit.
Key FindingCombining ECG leads increased the usable recording time from 92% to 97% in flight and from 96% to 98% before flight. High-force movement fell from just over 2.5 hours per day before flight to about 50 minutes per day in orbit.
Raw signals
AccelerationECG
Data channels
Heart Rate
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & Surgery
Matheson, D. J., Burnett, R. A., Kapron, C. R., Blackburn, B. E., Gililland, J. M., Anderson, L. A., Pelt, C. E., Peters, C. L., & Archibeck, M. J. (2026). Severe Coronal Plane Deformity Correction in Total Knee Arthroplasty Is Associated With Increased Surgeon Physiologic Demand. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.01.013
SummaryThe study compared surgeon physiologic demand across coronal plane deformity groups in primary total knee arthroplasty. The study included eighty-five patients undergoing primary, elective cemented TKA, stratified by a 10 degree hip-knee-ankle angle threshold into mild varus, moderate/severe varus, mild valgus, and moderate/severe valgus groups. A Hexoskin smart garment worn by the operating surgeon recorded heart rate, minute ventilation, and energy expenditure during primary TKA cases. Energy expenditure differed across the four groups (P < 0.001). The garment itself was not evaluated.
Key FindingIn multilevel models, the operating surgeon’s Hexoskin-estimated energy expenditure was higher for mild valgus (P = 0.026) and moderate/severe valgus (P = 0.002) versus mild varus. Heart rate (P = 0.16) and minute ventilation (P = 0.23) did not differ across the four groups.
Membership of GITES, Alarcos, B., Díaz-Pulido, B., Fernández, O., Fernández-Guinea, S., Herraiz, A. G., Lendínez-Chica, M. D. M., Muela, J. M., Nunez-Nagy, S., Pérez-Martín, Y., Rodríguez-Costa, I., González, G. M. R., Trapero-Asenjo, S., & Velasco, J. R. (2026). Detection of balance in the elderly under the influence of stress (DEPIE): A cross-sectional study protocol. PLOS One. https://doi.org/10.1371/journal.pone.0341744
Mesuda, Y., Yukoya, S., Asanuma, K., Kayama, M., Itoh, K., Ikeda, K., Yamashita, Y., Nagai, T., Tamaguchi, M., Obata, A., & Tani, T. (2024). 歌唱習熟者の歌唱時の呼吸運動における傾向. 研究報告音声言語情報処理(SLP), 2024-SLP-152 (情報処理学会). https://ipsj.ixsq.nii.ac.jp/records/234752
Mezghani, N., Ouakrim, Y., Islam, M. R., Yared, R., & Abdulrazak, B. (2017). Context aware adaptable approach for fall detection based on smart textile. In 2017 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) (pp. 473–476). IEEE. https://doi.org/10.1109/BHI.2017.7897308
Minns, S. A., Martins-Klein, B., Zapetis, S. L., Xu, E. P., Li, J., León, G. A., Turnamian, M. R., Webb, D., Tharanipathy, A., Givens, E., & Stange, J. P. (2026). When breath lifts your mood: Dynamic everyday links between breathing, affect, and emotion regulation in remitted depression. Journal of Affective Disorders. https://doi.org/10.1016/j.jad.2025.120686
SummaryThe study investigated within-person time-lagged associations between respiratory parameters and subsequent high-arousal positive affect. Participants included adults aged 18-30 years with remitted major depressive disorder or no lifetime psychiatric history. The Hexoskin smart shirt was worn during a 7-day EMA period to continuously record respiration via RIP sensors. Breathing rate and minute ventilation predicted greater high-arousal positive affect 30 minutes later. The shirt was not evaluated against a reference.
Key FindingHigher Hexoskin minute ventilation (B = 0.036, SE = 0.015, p = .014) and breathing rate (B = 0.052, SE = 0.022, p = .018) predicted greater high-arousal positive affect 30 minutes later.
HexoskinAcademic ThesisData Science & Artificial IntelligenceClinical Medicine & Surgery
Early Detection and Self-Management of Long-Term Conditions using Wearable Technologies: An Application of Pre-diabetes Detection and Self-management of Diabetes Type – II
Baig, M. M. (2017). Early Detection and Self-Management of Long-Term Conditions using Wearable Technologies: An Application of Pre-diabetes Detection and Self-management of Diabetes Type – II. Auckland University of Technology, Master of Computer and Information Sciences (MCIS) thesis.
SummaryThis thesis proposed a wearable-data system for early prediabetes detection and type II diabetes self-management. Two participants supplied demographic, vital-sign, activity, blood-glucose, and HbA1c data, and one used a Hexoskin vest for real-time monitoring. An adaptive neuro-fuzzy inference model and individualized interpretation engine combined the available inputs. The thesis reports system-level performance estimates but does not provide a clinical validation cohort.
Key FindingThe proposed system reported 91.49% accuracy, 94% sensitivity, and 90% specificity. With only two participants and limited wearable use, those figures should be treated as prototype results rather than evidence of clinical diagnostic performance.
Rothstein, A., Hirsch, J., Hillian, A., & DiFrancisco-Donoghue, J. (2025). A Randomized Control Trial Comparing the Effects of N-95 Respirator Versus Surgical Mask Use on Resting Metabolic and Respiratory Changes. Journal of Occupational & Environmental Medicine, 67(5), 339-343. https://doi.org/10.1097/jom.0000000000003322
SummaryForty-two adults completed randomized 15-minute resting trials wearing no mask, a surgical mask or an N95 respirator. Hexoskin recorded heart rate, respiratory rate and minute ventilation. Masks produced small increases in respiratory exchange ratio, minute ventilation and perceived exertion, with the highest perceived exertion in the N95 condition.
Key FindingDuring resting mask trials that included Hexoskin monitoring, surgical and N95 masks caused small resting metabolic and respiratory changes that remained within expected physiological ranges.
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinConference AbstractNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Ishii, M. (2019). Respiratory responses reflecting the emotional contribution to freezing of gait in Parkinson's disease. WPC 2019 Abstracts. https://doi.org/10.3233/jpd-199900
Nawawi, M. M., Sidek, K. A., Azman, A. W., & Nasir, N. F. M. (2021). Reliability of Electrocardiogram Signals during Feature Extraction Stage for Smart Textile Shirts. Journal of Physics: Conference Series 2071 (2021) 012043; International Conference on Biomedical Engineering (ICoBE 2021). https://doi.org/10.1088/1742-6596/2071/1/012043
Mohd Nawawi, M. M., Sidek, K. A., & Azman, A. W. (2023). ECG biometric in real-life settings: Analysing different physiological conditions with wearable smart textiles shirts. Bulletin of Electrical Engineering and Informatics, 12(5), 2930–2938. https://doi.org/10.11591/eei.v12i5.5133
SummaryThis study evaluated ECG biometric authentication from Hexoskin ProShirt recordings under different physiological conditions. Eleven participants were recorded while standing, sitting, walking and completing uncontrolled activity. After filtering and QRS-based feature extraction, 854 samples were used for training and validation and 300 for testing a quadratic support-vector machine. The study assessed the classifier rather than validating Hexoskin against a clinical ECG reference.
Key FindingThe biometric classifier evaluated on Hexoskin ProShirt ECG reported accuracy above 98%, a 0.93% false-acceptance rate, a 3.64% false-rejection rate and a true-positive rate above 96% on the in-house dataset. Results from 11 participants and sample-level model development do not establish performance in larger populations or independent deployments.
Mohd Nawawi, M. M., Sidek, K. A., & Azman, A. W. (2024). Biometric analysis on smart textile garment in real life scenario. Journal of Advanced Research in Applied Sciences and Engineering Technology, 34(1), 372–386. https://doi.org/10.37934/araset.34.1.372386
SummaryThis study evaluated ECG biometrics from two commercially available smart-textile shirts under a real-life recording protocol. Twenty-two healthy participants wore either a Hexoskin ProShirt or a HeartIn Fit shirt for at least 15 minutes. Hexoskin recorded ECG at 256 Hz through three textile electrodes. A tuned quadratic support-vector machine achieved 97.4% accuracy, but the small healthy sample and short brand-specific recordings do not establish broader biometric performance.
Key FindingAcross ECG recordings from participants wearing either Hexoskin or HeartIn Fit shirts, a tuned quadratic support-vector machine achieved 97.4% accuracy across the study data; the result comes from 22 healthy participants and short recordings from two different shirt brands.
Mohd Nawawi, M. M., Sidek, K. A., & Azman, A. W. (2024). ECG in real world scenario: Time variability in biometric using wearable smart textile shirts. Journal of Advanced Research in Applied Sciences and Engineering Technology, 40(2), 36–49. https://doi.org/10.37934/araset.40.2.3649
SummaryThe study assessed electrocardiogram signals from Hexoskin ProShirt and HeartIn Fit shirts for biometric verification in real-world settings. The study collected data from 22 participants over more than 30 days. Participants wore commercial Hexoskin ProShirt or HeartIn Fit smart-textile shirts. The method combined time-domain preprocessing, QRS feature extraction, and a quadratic support-vector-machine classifier. The sample comprised 22 healthy participants, including 18 men and 4 women.
Key FindingThe classifier achieved accuracy above 99.63%, a 0.14% false-acceptance rate, a 2.86% false-rejection rate, and a 97.14% true-positive rate. The classifier used approximately 854 datasets for training and validation and 300 datasets for testing. Because the dataset combined Hexoskin and HeartIn shirts, the reported classifier performance was not Hexoskin-specific.
Raw signals
ECG
HexoskinAcademic ThesisValidation & Methodology
Remote vital signs monitoring using a mm-wave FMCW radar
Alizadeh, M. (2019). Remote vital signs monitoring using a mm-wave FMCW radar. University of Waterloo (MSc thesis, Electrical and Computer Engineering).
SummaryThis thesis developed a millimeter-wave frequency-modulated continuous-wave radar method for non-contact monitoring of breathing and heart rate. One healthy male participant was recorded while sitting or sleeping in different positions, with a Hexoskin vest supplying the reference breathing and cardiac signals. Signal processing included phase correction, harmonic analysis, and adaptive filtering for waveform reconstruction. Reported worst-case accuracy was 95% for breathing rate and 94% for heart rate within the study's stated tolerances.
Key FindingRadar estimates closely tracked the Hexoskin reference in the reported single-participant experiments, including a 40-minute back-sleeping trial. The one-person design and controlled geometry prevent generalization to clinical monitoring or diverse sleepers.
Validité de critère du textile intelligent Hexoskin pour évaluer la fonction cardiorespiraoire chez une population en santé.
Mouzoune, I., Gaudreault, N., Mezghani, N., & Boulay, P. (2017). Validité de critère du textile intelligent Hexoskin pour évaluer la fonction cardiorespiraoire chez une population en santé.. 2nd Quebec Congress in Adaptation-Rehabilitation Research (2e Congrès québécois de recherche en adaptation-réadaptation), poster abstract book.
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinArticleNeuroscience, Sleep & CognitionOccupational Health & Human Factors
Nagy, S. I., Matuz, A., Vörös, V., Schiffer, Á., Maróti, P., Hillebrand, P., Bandi, S., & Vas, B. (2026). Effects of virtual reality training on musical performance-related physiological responses: A mixed-reality physiological study. Computers in Human Behavior Reports. https://doi.org/10.1016/j.chbr.2026.100999
SummaryThis study tested a mixed-reality virtual-reality training program for music performance anxiety. The study included 15 students (19 enrolled, 4 excluded). The analysis used linear mixed-effects models per metric with group × session interaction, instrument type and gender as fixed effects and subject as random effect. Hexoskin smart shirts were worn during the resting state, baseline and exam sessions as the physiological monitoring tool, recording single-channel ECG and thoracic and abdominal respiration from which heart rate, respiratory rate and variability measures were derived. No significant training effect was detected, but the small sample and sensitivity analysis indicated limited power for small physiological effects.
Key FindingNo significant effect of the virtual-reality training on physiological responses monitored with Hexoskin was detected; with 15 analyzed students, the study had limited power to detect small effects.
Nguyen, E., Robert, M., Ding, T. Y., Gharbi, O., Jahani, A., St-Jean, J., Rodriguez, C., Wabi, I. S., Lazo, D. A. G., Nguyen, D. K., & Bou Assi, E. (2025). Assessment of a biometric shirt for sleep body position identification in epilepsy. Frontiers in Neurology. https://doi.org/10.3389/fneur.2025.1662988
SummaryThe study evaluated the Hexoskin shirt for identifying sleep body positions in patients with epilepsy. The study included 10 adult patients admitted to the CHUM epilepsy monitoring unit for at least 48 hours. The Hexoskin built-in accelerometer sleep position classification algorithm was compared second by second with blinded video-EEG annotations. The analysis included 347 hours of sleep from 40 nights.
Key FindingThe Hexoskin algorithm achieved 65% prone, 75% supine, 94% right lateral decubitus, 81% left lateral decubitus, and 65% sitting/standing classification accuracy compared to VEEG. Excluding intermediate positions (336 h) resulted in 80% prone, 76% supine, and 84% left classification accuracy. Results are based on a sample of 10 patients.
AMD: Analysis of Mood Dysregulation - A Machine Learning Approach
Wergeles, N. M. (2016). AMD: Analysis of mood dysregulation - A machine learning approach. University of Missouri-Columbia.
SummaryThis thesis developed a machine-learning pipeline for analyzing mood dysregulation from wearable physiology and self-reports. Forty women receiving treatment for emotional-distress disorders enrolled, while the prediction module ultimately analyzed seven participants after data availability and quality filters. Hexoskin collected ECG, respiration, and activity during approximately two weeks of daily life, and self-reported mood dysregulation supplied the target labels. Decision-tree, random-forest, Bayesian-network, and naive-Bayes models were evaluated after feature engineering and class balancing.
Key FindingThe all-subject random-forest model reported 95.84% accuracy and a ROC area of 99.2%, while the J48 decision tree reported 93.46% accuracy. These results came from a small filtered sample with resampled classes and require external validation before any clinical interpretation.
Nishibe, T., Domoto, H., Uchiya, T., Takumi, I., & Funase, A. (2025). Investigation of Effective Heart Rate Variability Indices for Emotion Estimation During Long-term Images Gazing. IIAI Letters on Informatics and Interdisciplinary Research, Vol.006 (IIAI Open Conference Publication Series). https://doi.org/10.52731/liir.v006.330
Raw signals
ECG
Data channels
Breathing RateRR Interval
HexoskinConference AbstractOccupational Health & Human FactorsNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Tracking Mental Workload by Multimodal Measurements During Minimally Invasive Surgery Training
Chatty, L., Omurtag, A., Roy, R., & Garbey, M. (2017). Tracking Mental Workload by Multimodal Measurements During Minimally Invasive Surgery Training. Surg Endosc.
Raw signals
Respiration
HexoskinConference PaperOccupational Health & Human FactorsNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Omurtag, A., Roy, R. N., Dehais, F., Chatty, L., & Garbey, M. (2018). Tracking Team Mental Workload by Multimodal Measurements in The Operating Room. Neuroergonomics: The Brain at Work and in Everyday Life (Academic Press). https://doi.org/10.1016/b978-0-12-811926-6.00016-6
Raw signals
ECG
Data channels
Breathing RateHeart Rate
HexoskinStudy ProtocolClinical Medicine & SurgeryValidation & Methodology
Othman, H., Hannon, B., Liu, Z. A., Raman, S., Sexton, E., Kasper, C., Auger, H., Tsai, C. J., Barry, A., & Wong, P. (2025). Patient Reported Outcomes/Metrics Program Trial (PROMPT)- palliative radiation: protocol of a prospective observational feasibility study. Annals of Palliative Medicine. https://doi.org/10.21037/apm-25-19
Otis, S., Mezghani, N., & Abdulrazak, B. (2018). Comparative Study of Heart Rate Extraction Methods for a Novel Intelligent Mattress. 2018 9th International Symposium on Signal, Image, Video and Communications (ISIVC). https://doi.org/10.1109/isivc.2018.8709083
Détection automatique des crises d'épilepsie par un chandail connecté
Gharbi, O. (2024). Détection automatique des crises d'épilepsie par un chandail connecté. Université de Montréal, Département de neurosciences, Faculté de médecine (M.Sc. thesis).
SummaryThis thesis developed a machine-learning system to detect focal to bilateral tonic-clonic seizures from Hexoskin electrocardiography and accelerometry recorded alongside video-EEG. Of 148 adults recruited in an epilepsy monitoring unit, 42 participants with epilepsy contributed 66 seizures and 8,067.9 hours of recordings to the analysis. An XGBoost classifier combined heart-rate-variability and movement features, with video-EEG serving as the reference. The reported system reached 84.8% sensitivity, a median 0.55 false alarms per 24 hours, and a ROC-AUC of 0.90.
Key FindingThe shirt-based system detected 56 of 66 seizures, with median time in false warning of 10 seconds per alarm. Performance was measured in a monitored epilepsy-unit cohort and does not establish effectiveness for unsupervised home use.
Predicting Viral Respiratory Tract Infections Using Wearable Garment Biosensors
Jlassi, O. (2023). Predicting Viral Respiratory Tract Infections Using Wearable Garment Biosensors. Université de Montréal, Département d'informatique et de recherche opérationnelle (M.Sc. thesis).
SummaryThis thesis examined whether physiological signals from Hexoskin and Astroskin garments could help predict vaccine-induced inflammation as a model of viral respiratory infection. Fifty-five healthy adults wore a garment during a 12-day protocol that included repeated three-minute stair-stepping tests before and after live attenuated influenza vaccination. Heart rate, breathing rate, minute ventilation, and RR-interval features were used in XGBoost and random-forest models. In a five-participant test cohort, the best model used heart-rate-variability features from the first recovery minute and achieved an AUC of 0.73.
Key FindingThe best reported test result combined XGBoost with recovery-period heart-rate-variability features, yielding 0.70 sensitivity, 0.77 specificity, and 0.75 precision. The test set contained only five participants, so the result is preliminary and does not establish clinical infection detection.
Parker, R., & Slamon, N. (2018). A prospective study of biometric parameters of critical care practitioners during simulation. Critical Care Medicine, Volume 46, Number 1 (Supplement). https://doi.org/10.1097/01.ccm.0000528429.94475.ff
Data channels
Breathing RateCadenceHeart Rate
HexoskinConference PaperOccupational Health & Human Factors
L'origine de l'objectif est-elle importante? Effets motivationnels d'objectifs autodéfinis en production
Passalacqua, M., Pellerin, R., Magnani, F., Joblot, L., Yahia, E., Rosin, F., & Léger, P. M. (2023). L'origine de l'objectif est-elle importante? Effets motivationnels d'objectifs autodéfinis en production. CIGI Qualita MOSIM 2023.
Raw signals
AccelerationECGRespiration
Data channels
Breathing RateHeart RateRR Interval
HexoskinArticleOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Passalacqua, M., Pellerin, R., Yahia, E., Magnani, F., Rosin, F., Joblot, L., & Léger, P. M. (2024). Practice With Less AI Makes Perfect: Partially Automated AI During Training Leads to Better Worker Motivation, Engagement, and Skill Acquisition. International Journal of Human–Computer Interaction. https://doi.org/10.1080/10447318.2024.2319914
SummaryThe study compared no, full, and partial AI decision-selection automation during manufacturing training. A total of 102 participants completed the study, and 100 were retained for analysis. The Hexoskin smart vest recorded electrocardiography, respiration, and acceleration as engagement measures. Outcomes included task performance, error detection, motivation, and cognitive, emotional, and behavioral engagement. The Hexoskin vest served as a monitoring tool and was not evaluated as a device.
Key FindingAI automation level had a significant effect on error-detection performance: F(2, 27) = 5.65, p = .009. Physical-effort variability was lower with partial than full automation: t = -5.18, p < .001. Neither the LF/HF ratio nor respiration rate differed across automation levels in the Hexoskin monitoring data.
Raw signals
AccelerationECGRespiration
Data channels
Breathing Rate
HexoskinArticleData Science & Artificial IntelligenceOccupational Health & Human Factors
Pavan, K., Singh, A., Igasaki, T., Pawar, D. S., & Ganapathy, N. (2024). Assessment of driver’s stress state using smart T-shirt textile electrodes and multimodal cross-attention networks. IEEE Sensors Letters, 8(10), Article 6013804. https://doi.org/10.1109/lsens.2024.3458931
SummaryThis controlled study evaluated textile electrodes and a cross-attention model for driver-stress classification. Fifteen healthy male volunteers wore Hexoskin shirts during baseline and stress-driving scenarios lasting about one hour each. The shirts recorded one-lead ECG at 256 Hz and respiration at 128 Hz, while the study also collected vehicle kinematics. The model achieved 79% average accuracy and a 75% average F-score, but the small all-male sample and two controlled scenarios limit generalizability.
Key FindingIn simulated driving, the multimodal model incorporating Hexoskin measurements achieved 79% average accuracy and a 75% average F-score in 15 healthy male volunteers; performance outside the two controlled driving scenarios remains untested.
Raw signals
ECGRespiration
HexoskinConference PaperData Science & Artificial IntelligenceOccupational Health & Human FactorsValidation & Methodology
Pavan, K., Roha, V. S., Igasaki, T., Karthick, P. A., Pawar, D. S., & Ganapathy, N. (2024). Classifying driver distraction with textile electrocardiograms. In 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 1–4). IEEE. https://doi.org/10.1109/embc53108.2024.10782613
SummaryTen licensed drivers wore a Hexoskin shirt that recorded single-lead ECG during baseline driving, texting and calling in a controlled setting. Researchers divided the ECG into 10-, 30- and 60-second segments to train a convolutional neural network to distinguish the three conditions. On the validation set, the model achieved 67.12% average accuracy and a weighted F-score of 0.65.
Key FindingA model using Hexoskin ECG to classify distraction during driving achieved weighted F-scores of 0.53 to 0.75 when each driver was tested separately from the drivers used for training.
Raw signals
ECG
HexoskinConference PaperData Science & Artificial IntelligenceOccupational Health & Human Factors
Pavan, K., Singh, A., Pawar, D. S., & Ganapathy, N. (2025). Assessment of driver inattention state using multimodal wearable signals and cross-attention-driven hierarchical fusion. In J. Mantas, A. Hasman, E. Zoulias, K. Karitis, P. Gallos, M. Diomidous, S. Zogas, & M. Charalampidou (Eds.), Envisioning the future of health informatics and digital health (Studies in Health Technology and Informatics, Vol. 323, pp. 121–125). IOS Press. https://doi.org/10.3233/shti250061
SummaryTen male volunteers wore Hexoskin shirts while driving normally and while making phone calls under controlled conditions. The shirts recorded single-lead ECG at 256 Hz and respiration at 128 Hz; the researchers combined the signals in a neural network. They tested the model on one driver at a time, training it on the remaining drivers.
Key FindingCombining Hexoskin ECG and respiration early in the model yielded 65.55% accuracy and a 62.77% F1 score for distinguishing normal driving from driving during a phone call.
Peers, D., Eales, L., Jones, K., Toth, A., Acharya, H., & Richman–Eisenstat, J. (2021). Singing and Dancing With Neuromuscular Conditions: A Mixed-Methods Study. Adapted Physical Activity Quarterly. https://doi.org/10.1123/apaq.2020-0133
SummaryThis mixed-methods study examined a 15-week singing and dancing program for adults with neuromuscular conditions. Six participants with neuromuscular conditions entered the research study, but each outcome had a smaller and different sample. A modified Hexoskin shirt provided respiratory monitoring during weekly 90-minute sessions and was calibrated to spirometry. Four participants donned the shirt and two wore it consistently across the program.
Key FindingAverage Hexoskin respiratory rate remained stable across 15 weeks in the two consistently monitored participants, with no difference between choir and dance sessions. Spirometry was stable in two participants and improved in one, while quality-of-life improvements were reported for two participants. The very small, incomplete outcome samples make these feasibility findings preliminary.
Pelgröm, A. T., de Jongh, F. H. C., Aardweg, J. G. V. D., & van Veen, I. H. P. A. A. (2025). Analysis of the breathing pattern in patients with asthma during physical exercise: A cross-sectional study. Respiratory Medicine. https://doi.org/10.1016/j.rmed.2025.108037
SummaryThis cross-sectional study compared exercise breathing patterns and dyspnoea in adults with well-controlled asthma and healthy adults. The study enrolled 32 adults, 16 with asthma and 16 healthy controls; 30 completed the protocol and were analyzed, 15 per group. The primary outcome was breathing pattern quantified by the new BP angle, arctan of delta VT (cL) over delta BF times FVC between 40 % and 60 % of max load, with a 45 deg cut-off. All subjects wore a Hexoskin vest to measure thoracic and abdominal breathing with respiratory inductance plethysmography, but the authors state these measurements fall outside the scope of this paper. Mean BP angle was similar in asthma and healthy groups (66.8° ± 25.4° vs 72.9° ± 26.4°); these measurements came from the metabolic cart, not Hexoskin.
Key FindingAcross both groups, participants with BP angle ≤45° reported greater peak dyspnoea than those above 45° (visual analogue scale 86.5 vs 65.5 mm, p = 0.036; Borg 8 vs 4, p = 0.001); the result did not use Hexoskin data.
HexoskinAcademic ThesisOccupational Health & Human FactorsExercise Physiology & Sports ScienceNeuroscience, Sleep & Cognition
Marcel-Millet, P. (2020). Étude des réponses psychophysiologiques des sapeurs-pompiers lors des interventions de lutte contre les incendies. Université de Bourgogne Franche-Comté, École doctorale n°554 Environnements-Santé. https://doi.org/10.70675/cd818ffcz9770z4f9ez8b94z8c422d79653c
SummaryThis thesis examined psychophysiological responses of firefighters during simulated fire-suppression interventions across five related studies. Hexoskin continuously recorded physiological and activity measures during fitness testing, simulated interventions, recovery periods, and selected on-call nights. The studies addressed workload, cardiac parasympathetic recovery, day-versus-night stress, post-exercise heart-rate-variability methods, and sleep during on-call duty. Participant counts differed by study and ranged from 13 to 34 firefighters.
Key FindingOn-call nights with an intervention had a mean Hexoskin total sleep time of 281.5 minutes, compared with 432.2 minutes on control nights and 399.5 minutes on on-call nights without an intervention. These small, related studies used simulated or station-based conditions and do not establish causal operational outcomes.
Raw signals
AccelerationECGRespiration
Metrics
Sleep EfficiencyTime to Fall AsleepTotal Sleep Time
Reliability and Validity of the Hexoskin Wearable Body Metrics Telemetry Shirt
Phillips, M., Beach, J., Cathey, M., Lockert, J., & Satterfield, W. (2017). Reliability and Validity of the Hexoskin Wearable Body Metrics Telemetry Shirt. Journal of Sport and Human Performance (J Sport Hum Perf).
SummaryThis small laboratory study examined the reliability and validity of Hexoskin during moderate and vigorous treadmill exercise. Six healthy trained adults completed 15-minute bouts on nine testing days over three weeks. Calories per minute, breathing rate and heart rate were compared across repeated tests and, where applicable, with a ParvoMedic metabolic cart. The shirt was the device under evaluation.
Key FindingHexoskin calorie estimates showed strong reliability and criterion validity during vigorous exercise but weaker, nonsignificant results during moderate exercise. Breathing-rate validity was high at both intensities, while test-retest reliability was inconsistent and improved after two outliers were removed. The six-person sample and outlier sensitivity make the estimates preliminary.
Effect of Heat on Psycho-Physiological Responses During a Self-Paced Cycling Time Trial
Pirlot, T., Baron, B., Ravier, G., & Groslambert, A. (2025). Effect of Heat on Psycho-Physiological Responses During a Self-Paced Cycling Time Trial. Journal of Science and Cycling (Science and Cycling Conference, Lille 2025).
Pourbemany, J., Essa, A., & Zhu, Y. (2021). Real Time Video based Heart and Respiration Rate Monitoring. arXiv (eess.IV). https://arxiv.org/abs/2106.02669
Pourbemany, J., & Zhu, Y. (2023). Cross Body Signal Pairing (CBSPCR): A Key Generation Protocol for Pairing Wearable Devices with Cardiac and Respiratory Sensors. Annual Computer Security Applications Conference (ACSAC '23). https://doi.org/10.1145/3627106.3627185
Rabineau, J., Hedge, E. T., Fournier, R., Mastrandrea, C. J., & Hughson, R. L. (2025). Heart rate variability during exercise can quantify cardiorespiratory deconditioning in 55- to 65-yr-old men and women exposed to head-down bed rest. J Appl Physiol. https://doi.org/10.1152/japplphysiol.00017.2025
SummaryThe study evaluated cardiorespiratory deconditioning induced by head-down bed rest in late middle-aged adults. Twenty-two healthy participants, aged 55 to 65 years, were included in the study. Participants wore the Hexoskin smart t-shirt to record a one-lead electrocardiogram during incremental cycle ergometer tests. The analysis included 68 of 88 planned test records. Baseline correlation was r = 0.90 (P < 0.001) for VO2 at HRV0.75 vs VT1 and r = 0.93 (P < 0.001) for HRV0.5 vs VT2.
Key FindingFor thresholds derived from Hexoskin ECG, the control group repeated-measures correlation was rrm = 0.66 (0.32; 0.84) for HRV0.75 vs VT1 and rrm = 0.82 (0.61; 0.92) for HRV0.5 vs VT2 (both P < 0.001). The analysis was based on 68 of 88 planned test records.
Rahman, T., Adams, A. T., Ravichandran, R. V., Zhang, M., Patel, S. N., Kientz, J. A., & Choudhury, T. (2015). DoppleSleep: A Contactless Unobtrusive Sleep Sensing System Using Short-Range Doppler Radar. UbiComp '15, Osaka, Japan. https://doi.org/10.1145/2750858.2804280
Raw signals
AccelerationECGRespiration
Data channels
Breathing RateHeart Rate
HexoskinConference AbstractOccupational Health & Human FactorsClinical Medicine & Surgery
Redmond, B., Ray, J., Joseph, M., Bruno, C., Gross, I., Auerbach, M., & Johnston, L. (2019). Analyzing physiologic markers as surrogates for provider stress and distress for participants in a procedural training bootcamp [Poster abstract No. 201]. Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare, 14(4), e39. https://journals.lww.com/01266021-201908000-00012
SummaryEmergency medicine residents wore Hexoskin vests during three neonatal intubation simulations designed to become progressively more stressful. The researchers compared continuous heart and breathing measurements with participants’ ratings, observer reports and procedural performance. The poster described heart-rate spikes in all 14 participants, although their own accounts of stress did not always match observers’ assessments.
Key FindingIn a neonatal airway simulation using Hexoskin, 70% of post-scenario responses indicated stress, but residents felt stress had affected their performance only a quarter of the time.
Data channels
Breathing RateCadenceHeart RateMinute Ventilation
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & Surgery
Redmond, B., Joseph, M., Ray, J., Shabanova, V., Gross, I. T., Bruno, C., McPadden, J., Auerbach, M., & Johnston, L. (2020). Stress as tool or toxin: Physiologic markers and subjective report in neonatal simulation. Pediatric Research, 88(5), 784–791. https://doi.org/10.1038/s41390-020-0806-9
SummaryThis single-center simulation study examined subjective and physiological stress across three increasingly stressful neonatal-resuscitation scenarios. Twelve emergency-medicine residents wore Hexoskin shirts continuously from the initial survey through the final debriefing. Heart-rate variability served as an objective stress marker, while surveys assessed perceived stress and affect and intubation success represented procedural performance. Each participant served as their own baseline control.
Key FindingThe median LF/HF ratio derived from Hexoskin cardiac recordings increased from 2.29 in the first scenario to 4.70 and 4.63 in the second and third scenarios (P=.04 for each comparison). Physiological changes occurred even when participants did not report corresponding stress, and procedural proficiency declined in the more stressful scenarios. The 12-person simulation study does not establish effects during live neonatal care.
HexoskinArticleNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Rodríguez-Costa, I., Díaz-Pulido, B., Pérez-Martín, Y., Nunez-Nagy, S., Valero-Gil, M. Á., Cano-Hernamperez, A., & Trapero-Asenjo, S. (2026). Ageing Population and Balance Under Stressful Conditions-A Cross-Sectional Observational Study. Healthcare. https://doi.org/10.3390/healthcare14020237
SummaryThis cross-sectional study tested whether an acute emotional stressor changed fast-paced Timed Up and Go performance in older adults. The study included 31 participants. The analysis assessed TUG time before and after stressful IAPS image exposure. The Hexoskin Pro vest was worn as a monitoring tool to record the physiological data used for HRV calculation before and during viewing of stressful images, to confirm stress induction. The study reported HF (ln) 3.54 ± 0.5 pre-stress vs 3.19 ± 0.61 stress, t(30) = 3.64, p = 0.001, d = 0.653.
Key FindingIn a balance study using Hexoskin cardiac monitoring, mean Timed Up and Go time increased after the stressor from 7.00 ± 1.16 s to 7.37 ± 1.40 s (p < 0.001); without a control group, the study cannot establish that stress caused the change.
HexoskinConference PaperOccupational Health & Human Factors
Salar, M., Capanoglu, M. F., Sherman, A., Sesek, R. F., & Davis, J. (2017). Training related risk factors of firefighters. Proceedings of the Human Factors and Ergonomics Society 2017 Annual Meeting. https://doi.org/10.1177/1541931213601941
HexoskinConference PaperOccupational Health & Human FactorsData Science & Artificial Intelligence
Salvan, L., Marois, A., Kopf, M., & Gagnon, J. F. (2022). Sensors-Enabled Human State Monitoring System for Tactical Settings. 2022 IEEE Conference on Cognitive and Computational Aspects of Situation Management (CogSIMA). https://doi.org/10.1109/cogsima54611.2022.9903277
Biomedical Signal Processing and Inference in Wearable Sensing Applications
Gutta, S. (2016). Biomedical signal processing and inference in wearable sensing applications. Oklahoma State University.
SummaryThis thesis developed methods for ECG-based biometric recognition, cardiorespiratory modeling, and sleep-apnea inference in wearable sensing applications. Hexoskin recorded one healthy 25-year-old man during an awake-to-sleep transition to compare real physiology with cardiorespiratory-model simulations. Separate biometric analyses used the MIT-BIH Normal Sinus Rhythm database rather than Hexoskin recordings. The garment therefore served as a limited physiological data source within a broader methodological dissertation.
Key FindingThe Hexoskin component demonstrated model comparison on a single healthy participant during an awake-to-sleep transition. It did not validate biometric recognition or sleep-apnea detection in a clinical population.
Sanz-Quinto, S., Girard, O., López-Grueso, R., Brizuela, G., & Moya-Ramón, M. (2022). Hematological and Ventilatory Responses to a 3900 M Altitude Sojourn in an Elite Wheelchair-marathoner. European Journal of Sport Sciences. https://doi.org/10.24018/ejsport.2022.1.1.2
SummaryThis single-athlete case study followed hematological and ventilatory responses during a five-week stay at 3,900 m. Hexoskin measured resting respiratory rate during five minutes of supine recording after awakening. Respiratory rate increased from 5.1 ± 0.4 breaths/min before altitude exposure to 9.1 ± 1.6 in week 1 and 9.3 ± 2.1 in week 2. Results from one elite wheelchair marathoner do not establish a general altitude response.
Key FindingResting respiratory rate measured with Hexoskin increased from 5.1 ± 0.4 breaths/min before altitude exposure to 9.1 ± 1.6 in week 1 and 9.3 ± 2.1 in week 2; this was a single-athlete case study.
Saygin, M., Schoenmakers, M., Gevonden, M., & de Geus, E. (2025). Speech Detection via Respiratory Inductance Plethysmography, Thoracic Impedance, Accelerometers, and Gyroscopes: A Machine Learning-Informed Comparative Study. Psychophysiology. https://doi.org/10.1111/psyp.70021
SummaryThis comparative laboratory study trained speech-detection models using wearable data from 56 adults. Hexoskin Pro shirts supplied thoracic and abdominal respiratory inductance plethysmography signals for the dual-band and thorax-only models. Test-set AUC was 98.5% for dual-band RIP, 99.1% for thorax-only RIP, 97.8% for impedance, and 99.6% for sternal accelerometry. The controlled speech tasks do not establish performance in daily life.
Key FindingIn controlled speech tasks involving 56 adults, a model using only the thoracic respiratory signal from Hexoskin reached a test-set area under the ROC curve of 0.991, compared with 0.985 using both respiratory bands. A separate sternal accelerometer reached 0.996; performance in everyday conversation remains untested.
Scataglini, S., Moorhead, A. P., & Feletti, F. (2020). A Systematic Review of Smart Clothing in Sports: possible Applications to Extreme Sports. Muscles, Ligaments and Tendons Journal. https://doi.org/10.32098/mltj.02.2020.19
SummaryThis systematic review examined smart clothing used in sports and its possible application to extreme sports. The authors screened 837 records after duplicate removal and included 24 studies covering 18 systems and 22 garment types. Astroskin was summarized as one of the available products and was described as measuring blood pressure, pulse oximetry, three-lead ECG, respiration, skin temperature and activity. The review did not collect new participant data with Astroskin.
Key FindingThe review identified 22 smart-clothing types across 24 included studies, with heart rate and respiratory rate among the commonly monitored signals. Astroskin was discussed as a commercial system rather than tested in a new validation study. Study-quality scores in the review ranged from two to five Newcastle-Ottawa stars.
Schlatter, S., Guillot, A., Schmidt, L., Mura, M., Trama, R., Di Rienzo, F., Lilot, M., & Debarnot, U. (2021). Combining proactive transcranial stimulation and cardiac biofeedback to substantially manage harmful stress effects. Brain Stimulation. https://doi.org/10.1016/j.brs.2021.08.019
SummaryThis randomized study compared transcranial stimulation, cardiac biofeedback and their combination during an experimental stress protocol. Eighty healthy adults completed the analysis after five of 85 enrolled participants were excluded. Hexoskin continuously tracked cardiac activity during the second session, which included baseline, anticipatory stress, a 15-minute intervention, the Trier Social Stress Test and cognitive tasks. Five-minute segments were used for heart-rate-variability analysis.
Key FindingIn a study that used Hexoskin to monitor cardiac responses during stress, group-by-time interactions were reported for SDRR, pNN50 and LF/HF, while heart rate and cortisol did not show significant interactions and RMSSD showed a trend. The laboratory study tested short-term physiological and task responses in healthy volunteers and does not establish clinical stress-management benefit.
Data channels
Heart Rate
HexoskinArticleOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Schlatter, S., Louisy, S., Canada, B., Thérond, C., Duclos, A., Blakeley, C., Lehot, J. J., Rimmelé, T., Guillot, A., Lilot, M., & Debarnot, U. (2022). Personality traits affect anticipatory stress vulnerability and coping effectiveness in occupational critical care situations. Scientific Reports. https://doi.org/10.1038/s41598-022-24905-z
SummaryThis simulation study examined personality, anticipatory stress and coping responses in anesthesiology and critical-care residents. Hexoskin continuously monitored cardiac activity during anticipation, a coping intervention, a critical-care scenario, debriefing and final rest. The study enrolled 147 participants; 120 were included in anticipatory-stress models and 118 in cardiac-coherence models. Regression models tested Big Five traits and interactions with relaxation breathing, biofeedback or control conditions.
Key FindingIn a simulation study that recorded cardiac activity with Hexoskin, higher neuroticism was associated with greater psychological and cardiac anticipatory stress, while extraversion was associated with lower values on both measures. Openness interacted with relaxation breathing and biofeedback in the cardiac-coherence models. These associations come from a simulation setting and do not establish that personality traits cause clinical performance differences.
Schüler, W., Spicher, N., & Deserno, T. M. (2021). Cardiopulmonary coupling analysis using smart wearables and mobile computing. Current Directions in Biomedical Engineering. https://doi.org/10.1515/cdbme-2021-2074
SummaryThis feasibility study adapted cardiopulmonary-coupling analysis for a smartphone using overnight Hexoskin recordings. Four volunteers contributed 12 whole-night recordings; the shirt streamed ECG to the app and its respiratory-inductance signal served as the reference for ECG-derived respiration. ECG-derived respiratory rate differed from the shirt reference by 17.22% on average, or 3.54 breaths/min. The four-person feasibility study does not establish clinical sleep assessment.
Key FindingECG-derived respiratory rate differed from the Hexoskin respiratory-inductance reference by 17.22% on average (3.54 breaths/min); only four volunteers were studied.
Schüler, W., Bente, L. M., Deserno, T. M., & Kacprowski, T. (2024). Real-Time ECG-monitoring in Virtual Reality. Medical Imaging 2024: Imaging Informatics for Healthcare, Research, and Applications, Proc. of SPIE Vol. 12931. https://doi.org/10.1117/12.3006472
Heart Rate Variability Compared in a Trained and Untrained Population under Normoxic and Hypoxic Conditions
Wilson, S. L. (2015). Heart Rate Variability Compared in a Trained and Untrained Population under Normoxic and Hypoxic Conditions. California State University, Sacramento, Department of Kinesiology (Master of Science thesis).
SummaryThis thesis compared heart-rate variability in seven aerobically trained and six untrained men under normoxic and hypoxic conditions. Participants completed two randomized crossover visits with one hour of rest, ten minutes of submaximal exercise, and a five-minute cool-down. Hexoskin recorded ECG for SDNN calculation as well as heart rate during the protocol. The small study also compared blood pressure and oxygen saturation responses between training groups and conditions.
Key FindingAmong trained participants, exercise SDNN was lower in hypoxia than normoxia only at the study's exploratory 0.10 significance level, while untrained participants showed a significant heart-rate increase in hypoxia. The sample of 13 men was too small to establish general training-group effects.
Raw signals
ECG
Data channels
Heart Rate
Metrics
SDNN
HexoskinConference PaperOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Sharma, A., Léger, P. M., Cameron, A. F., Sénécal, S., & Coursaris, C. (2024). Impact of Smartphone Multitasking on Walking Behavior: Is Cognitive Absorption the Key?. SIGHCI 2023 Proceedings (Twenty-Second Annual Pre-ICIS Workshop on HCI Research in MIS). https://aisel.aisnet.org/sighci2023/15/
Data channels
Cadence
HexoskinConference PaperOccupational Health & Human Factors
Sharma, A., Cameron, A. F., Léger, P. M., Bayard-Arthur, E., Coursaris, C. K., & Sénécal, S. (2025). Smombies on the Move: Exploring the Role of Digital Nudges. AMCIS 2025 Proceedings (Thirty-first Americas Conference on Information Systems, Montréal, 2025). https://aisel.aisnet.org/amcis2025/sig_core/sig_core/9/
Data channels
Cadence
HexoskinConference PaperOccupational Health & Human FactorsData Science & Artificial Intelligence
Sharotry, A., Jimenez, J. A., Wierschem, D., Mediavilla, F. A. M., Koldenhoven, R. M., Valles, D., Koutitas, G., & Aslan, S. (2020). A Digital Twin Framework for Real-Time Analysis and Feedback of Repetitive Work in the Manual Material Handling Industry. Proceedings of the 2020 Winter Simulation Conference (WSC). https://doi.org/10.1109/wsc48552.2020.9384043
A Method for Measuring Puffing and Respiratory Parameters of Tobacco Users within their Natural Usage Environment
Jayasekera, S. (2022). A Method for Measuring Puffing and Respiratory Parameters of Tobacco Users within their Natural Usage Environment. Rochester Institute of Technology (RIT Digital Institutional Repository).
SummaryThis thesis developed a method for measuring tobacco-puffing and respiratory patterns in natural-use settings. Hexoskin respiratory signals were calibrated to volume, compared with a spirometer, and synchronized with a wearable puffing topography monitor. The natural-environment deployment enrolled ten tobacco users and analyzed eight datasets from seven participants across cigarette and hookah use. The work evaluated measurement and synchronization methods rather than a clinical outcome.
Key FindingMean inhalation volume differed by about 27 mL between Hexoskin and the spirometer, approximately 4.5% of a roughly 600 mL mean inhalation volume. The small validation samples, long-term calibration variability, and mixed natural-use dataset limit broader accuracy claims.
Raw signals
Respiration
HexoskinArticleOccupational Health & Human FactorsExercise Physiology & Sports Science
A Mixed Method Approach to Assessing the Feasibility of Implementing the Ottawa Paramedic Physical Abilities Test (TM) in the Australian Context
Sheridan, S., Pope, R., MacPhee, R. S., MacQuarrie, A., Fischer, S., Buzza, G., Stack, H., Bolton, L., Grevell, J., Sheridan, C. T., Buckman, J., & Rayner, R. (2026). A Mixed Method Approach to Assessing the Feasibility of Implementing the Ottawa Paramedic Physical Abilities Test (TM) in the Australian Context. The Internet Journal of Allied Health Sciences and Practice.
SummaryThis mixed-method feasibility study assessed whether the Ottawa Paramedic Physical Abilities Test could be implemented in Australia. Twelve paramedicine students were recruited; two did not begin testing because resting vital signs exceeded safety thresholds, six completed all physical tests, and two met every pass or satisfactory standard. The analysis used feasibility outcomes in three groups: participant characteristics and test performance, feasibility of the tests for the Australian paramedicine context, and feasibility of Hexoskin monitoring. The Hexoskin Smart Garment with its datalogger was used as a monitoring tool to record heart rate, accelerometry and ventilation during the fitness tests. The study reported 6 of 12 participants completed all physical tests and 2 completed all to a pass or satisfactory standard.
Key FindingIn an Australian feasibility study using Hexoskin during a paramedic fitness assessment, six of 12 recruits completed all physical tests and two met the pass or satisfactory standard on every test. Two recruits did not start because their resting vital signs exceeded the safety thresholds.
Raw signals
Acceleration
Data channels
ActivityBreathing RateHeart Rate
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & Surgery
Shimada, A., Kanaji, S., Sugita, Y., Ikeda, T., Koterazawa, Y., Aoki, T., Harada, H., Otowa, Y., Urakawa, N., Goto, H., Hasegawa, H., Yamashita, K., Matsuda, T., & Kakeji, Y. (2026). Evaluating surgeons' stress using heart rate variability during minimally invasive surgery for gastric cancer: a single-center prospective cohort study. Langenbeck's Archives of Surgery. https://doi.org/10.1007/s00423-026-04056-9
SummaryThis single-center prospective cohort study examined how surgical approach and experience affected stress during minimally invasive distal gastrectomy. Four surgeons performed robot-assisted or laparoscopic procedures in 40 patients, while Hexoskin continuously recorded intraoperative heart rate variability. Stress was assessed with the LF/HF ratio across 10 standardized surgical steps, and postoperative workload was measured with NASA-TLX. Among qualified surgeons, robotic surgery was associated with lower stress than laparoscopy, especially during suprapancreatic lymph-node dissection.
Key FindingFor qualified surgeons wearing Hexoskin, normalized LF/HF was 0.48 with robotic versus 1.76 with laparoscopic surgery during right gastric artery dissection (P = 0.030).
Singh, A., Rehman, S. U., Yongchareon, S., & Chong, P. H. J. (2024). Human Vital Signs Estimation Using Resonance Sparse Spectrum Decomposition. IEEE Transactions on Human-Machine Systems. https://doi.org/10.1109/thms.2024.3381074
SummaryThis controlled study tested a radar method for estimating heart rate and respiratory rate in four participants. Hexoskin supplied the reference heart-rate and respiratory-rate measurements. The radar method used resonance sparse spectrum decomposition and harmonic processing to reduce clutter, motion, and respiratory interference. Accuracy was reported as 98%–100% within 2 beats per minute at distances up to 2 m, but the four-person laboratory study limits generalizability.
Key FindingThe radar method achieved 98%–100% heart-rate and respiratory-rate accuracy within 2 beats per minute up to 2 m against the Hexoskin reference; only four participants were tested.
Data channels
Breathing RateHeart Rate
HexoskinConference AbstractOccupational Health & Human Factors
Slamon, N., Penfil, S., Deutsch, E., & Nadkarni, V. (2016). Biometric stress tracking and analysis during acute ICU care using a novel biosensing garment. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000509806.93957.c4
Slamon, N. B., Penfil, S. H., Nadkarni, V. M., & Parker, R. M. (2018). A Prospective Pilot Study of the Biometrics of Critical Care Practitioners during Live Patient Care using a Wearable “Smart Shirt”. Journal of Intensive and Critical Care. https://doi.org/10.21767/2471-8505.100112
SummaryThis prospective pilot study monitored five pediatric critical-care physicians during live patient care. Hexoskin recorded heart rate, respiratory rate and heart-rate variability during baseline rest, patient rounds, tracheal intubation and central-line placement. Each participant was compared with their own baseline. The shirt was not compared with a reference device.
Key FindingMean heart rate measured with Hexoskin increased from 81 beats/min at baseline to 99 during intubation and 108 during central-line placement, while SD1/SD2 decreased from 0.244 to 0.180 and 0.167. The five-person pilot suggests measurable physiological stress during procedures but does not establish general performance or patient-outcome effects.
Data channels
Breathing RateHeart Rate
HexoskinConference AbstractOccupational Health & Human Factors
Slamon, N., Nadkarni, V., Penfil, S., & Parker, R. (2018). Analysis of heart rate and heart rate variability during live pediatric intensive care activities. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000528260.44703.62
Smith, J. P., Shehata, M., Powell, R. G., McGuire, P. F., & Smith, A. J. (2016). Physiological Features of the Internal Jugular Vein from B-Mode Ultrasound Imagery. ISVC 2016, Part II, LNCS 10073. https://doi.org/10.1007/978-3-319-50832-0_30
Raw signals
AccelerationECG
Data channels
Breathing Rate
HexoskinArticleValidation & MethodologyExercise Physiology & Sports ScienceOccupational Health & Human Factors
Smith, C. M., Chillrud, S. N., Jack, D. W., Kinney, P., Yang, Q., & Layton, A. M. (2019). Laboratory Validation of Hexoskin Biometric Shirt at Rest, Submaximal Exercise, and Maximal Exercise While Riding a Stationary Bicycle. Journal of Occupational and Environmental Medicine. https://doi.org/10.1097/jom.0000000000001537
SummaryThis laboratory study validated Hexoskin respiratory and cardiac measures during seated rest and incremental stationary cycling. Nineteen healthy bicycle commuters were tested; respiratory analyses included 17 participants and heart-rate analysis included 18. Respiratory rate, tidal volume and minute ventilation were compared with spirometry, and heart rate was compared with 12-lead ECG. Adjustment models for field use were also developed.
Key FindingDiscrepancies between Hexoskin and reference heart-rate and respiratory-rate measurements were below 10% across rest, submaximal and maximal stages, while tidal-volume and ventilation discrepancies varied by intensity. A sex- and body-weight-adjusted ventilation model reached R²=0.89 with RMSE 9.8 L/min. The healthy laboratory sample and activity-specific adjustment models do not establish accuracy in patients or unrestricted daily activity.
Sokol, M., Holuša, J., Hejda, J., Volf, P., Matějka, M., & Kutílek, P. (2026). Environmental conditions and cardiac autonomic function during an Antarctic summer expedition at James Ross Island. Scientific Reports. https://doi.org/10.1038/s41598-026-51221-7
SummaryThis study investigated cardiac autonomic function during an Antarctic summer expedition at James Ross Island. The study included twelve multinational expedition members, consisting of eight males and four females with a mean age of 36.2 ± 8.7 years. The Hexoskin Pro Smart Shirt served as one of three wearable ECG devices used to record single-lead ECG over 12-hour daytime windows. Data were collected during 12-hour daytime recordings every other day over a 49-day expedition, with 45 measurement days available. Results were pooled across all ECG devices, showing that a one SD decrease in outdoor temperature was associated with a +0.241 log-units pNN50.
Key FindingA one-standard-deviation decrease in outdoor temperature was associated with a 0.241-log-unit increase in pNN50, or approximately 27%. RMSSD declined approximately 22% over the 49-day period. The reported temperature associations were pooled across all ECG devices and were not Hexoskin-specific.
Sousa, A., Ahmad, S. L., Hassan, T., Yuen, K., Douris, P., Zwibel, H., & DiFrancisco-Donoghue, J. (2020). Physiological and Cognitive Functions Following a Discrete Session of Competitive Esports Gaming. Frontiers in Psychology. https://doi.org/10.3389/fpsyg.2020.01030
SummaryThis observational study measured physiological and cognitive changes during one competitive esports session in 17 participants. Nine played a first-person shooter and eight played a multiplayer online battle arena game, while Hexoskin monitored heart rate throughout approximately 2.5 hours of play. The rise from resting to peak heart rate was greater in the first-person-shooter group (p = 0.043). The small nonrandomized groups do not establish that game type caused the difference.
Key FindingThe rise from resting to peak heart rate measured with Hexoskin was greater during first-person-shooter play than multiplayer-online-battle-arena play (p = 0.043); the 17-person observational comparison does not establish causality.
Speckhard, A. D., Knous, J. L., & Coughlin, A. M. (2017). Comparison Of Physiological Demands Of Basketball Practice Sessions To A Pre-season Game. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000518634.25126.69
Spicher, N., Klingenberg, A., Purrucker, V., & Deserno, T. M. (2021). Edge computing in 5G cellular networks for real-time analysis of electrocardiography recorded with wearable textile sensors. arXiv. https://arxiv.org/abs/2107.13767
Raw signals
ECG
HexoskinArticleNeuroscience, Sleep & CognitionData Science & Artificial IntelligenceClinical Medicine & Surgery
St-Jean, J., Gharbi, O., Toffa, D. H., Tran, T. P. Y., Robert, M., Nguyen, D. K., & Bou Assi, E. (2025). Detection of focal impaired awareness seizures using a biometric shirt. Epilepsia Open. https://doi.org/10.1002/epi4.70099
SummaryThe study evaluated a shirt-based detection approach for seizures annotated on video-EEG blinded to shirt data. The participants included adult patients aged 19 to 61 years who experienced focal impaired awareness seizures. The Hexoskin biometric shirt was worn continuously by epilepsy monitoring unit patients to record respiration, ECG, and accelerometry. Features from respiration, ECG HRV, and acceleration were used with an XGBoost classifier and nested leave-one-subject-out cross-validation. At a firing power threshold of 0.65, the system detected 71 seizures with a mean sensitivity of 66%.
Key FindingAt a firing power threshold of 0.65, a seizure-detection system incorporating Hexoskin recordings achieved a mean sensitivity of 66% and a false alarm rate of 30.6 per 24 hours. The results include a subset of 13 out of 27 patients who demonstrated 100% event sensitivity.
Raw signals
AccelerationECGRespiration
Data channels
Breathing Rate
HexoskinArticleNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Stange, J. P., Li, J., Xu, E. P., Ye, Z., Zapetis, S. L., Phanord, C. S., Wu, J., Sellery, P., Keefe, K., Forbes, E., Mermelstein, R. J., Trull, T. J., & Langenecker, S. A. (2023). Autonomic complexity dynamically indexes affect regulation in everyday life. J Psychopathol Clin Sci. https://doi.org/10.1037/abn0000849
SummaryThis ambulatory study examined autonomic complexity and affect regulation in 37 young adults with remitted major depressive disorder and 28 healthy comparison participants. Hexoskin shirts recorded single-lead ECG and acceleration during waking hours for seven days, paired with six daily ecological momentary assessments. Heart-rate-variability metrics were calculated from five-minute segments within the 30 minutes before each post-survey. The analysis tested within-person changes in complexity during affect-regulation episodes and differences between groups.
Key FindingParticipants completed 1,269 pre-post survey pairs, and 947 post-surveys had valid Hexoskin data; wearable data were missing for 22% of completed post-surveys on average. RMSSD, sample entropy and DFA α1 were moderately to strongly correlated, while the study's regulation findings remain observational and specific to the monitored cohort.
Vukovic, S., Lee, R. H. Y., & Claydon, V. E. (2024). Validation of a Novel Method for Identifying Sleep-Disordered Breathing in Spinal Cord Injury. SFU Undergraduate Research Symposium Journal. https://journals.lib.sfu.ca/index.php/ugrs/article/view/6469
SummaryThis poster evaluated Astroskin signals for a study of sleep-disordered breathing after spinal cord injury. Researchers compared skin temperature and blood oxygen saturation with a digital thermometer and pulse oximeter, respectively. The poster distinguishes these sensor comparisons from its overnight recordings.
Key FindingSkin temperature correlated with the thermometer (r = 0.997), and oxygen saturation correlated with pulse oximetry (r = 0.943). The poster did not establish how accurately the system identifies individual breathing events.
SummaryResearchers reported home sleep recordings from four people with spinal cord injury and four healthy controls. The abstract presents the sensor comparisons in healthy controls separately from the overnight case series.
Key FindingIn healthy controls, Astroskin oxygen saturation had a reported bias of −2.95 percentage points relative to the reference, and skin temperature had a bias of −0.3 °C. Dynamic blood-pressure changes were captured poorly. These comparisons do not measure the ability to diagnose sleep-disordered breathing.
Raw signals
ECG
Data channels
SpO₂Temperature
HexoskinAcademic ThesisValidation & MethodologyClinical Medicine & Surgery
SummaryThis thesis developed video-based methods for non-contact monitoring of movement, respiration, and pulse in bed and clinical settings. Several experiments used healthy adults or older hospital patients, while one proof-of-concept recording used Hexoskin ECG as the reference for pulse signals extracted from visible and thermal video. The Hexoskin experiment involved one healthy volunteer who remained still for about 90 seconds, with ten seconds used in the comparison. Both the processed video region and Hexoskin ECG showed a dominant frequency of 0.9 Hz, or about 54 beats per minute.
Key FindingThe proof-of-concept video signal matched the Hexoskin ECG frequency in one brief, motionless recording. That result supports signal extraction under the tested conditions but does not validate continuous pulse monitoring across patients, motion, or sleep.
Sun, P., Wergeles, N. M., Zhang, C., Guerdan, L. M., Trull, T., & Shang, Y. (2016). ADA - Automatic Detection of Alcohol Usage for Mobile Ambulatory Assessment. 2016 IEEE International Conference on Smart Computing (SMARTCOMP). https://doi.org/10.1109/smartcomp.2016.7501676
Talpur, A., Shaikh, F. K., Baloch, N., Felemban, E., Khelil, A., & Alam, M. M. (2019). Validation of Wired and Wireless Interconnected Body Sensor Networks. Sensors. https://doi.org/10.3390/s19173697
SummaryThis study compared an experimental wired DigiAID body-sensor network with Hexoskin and then evaluated a wireless DigiAID design. Ten young adults wore DigiAID and Hexoskin simultaneously during sitting, walking, and sleeping, with Hexoskin serving as the commercial comparator for heart and respiratory rates. The dynamic power-control algorithm reduced node energy use by 3%–90% while maintaining packet reception. The paper does not state whether the separate wired and wireless participant groups were the same people, and its range-based comparisons do not establish clinical accuracy.
Key FindingThe wireless DigiAID power-control algorithm reduced node energy use by 3%–90%; the Hexoskin comparison concerned the separate wired network and used activity-specific normal ranges rather than a clinical reference.
Tan, D. Y. W., & Yong, T. H. (2017). Suitability of Smartshirt by Hexoskin to Monitor Heart Rate for Racket Sports. 2017 International Conference on Robotics, Automation and Sciences (ICORAS). https://doi.org/10.1109/icoras.2017.8308057
Data channels
Heart Rate
HexoskinAcademic ThesisOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Police Decision-Making: The Impact of Choice on Use-of-Force Decisions
Summerfield, T. S. L. (2017). Police Decision-Making: The Impact of Choice on Use-of-Force Decisions. University of Regina.
SummaryThis thesis investigated whether the number of available response choices influenced use-of-force decisions by Royal Canadian Mounted Police cadets. A total of 112 cadets were analyzed after three of 115 collected records were excluded for technical issues. Hexoskin measured heart rate as an index of physiological arousal during a high-threat judgment simulation, alongside performance, response time, and confidence measures. The design compared two limited-choice groups with one extensive-choice group.
Key FindingThe thesis reported no consistent pattern of physiological arousal across the choice conditions. Because the study used a training simulation and heart rate as an arousal proxy, it does not establish how choice structure affects real-world use-of-force outcomes.
Influence of Gestational Exercise on One-Month Infant Resting Autonomic and Cardiac Control
Schneider, T. N. (2022). Influence of Gestational Exercise on One-Month Infant Resting Autonomic and Cardiac Control. East Carolina University.
SummaryThis thesis examined resting autonomic and cardiac measures in one-month-old infants whose mothers had been assigned to different exercise programs during pregnancy. Hexoskin recorded infant heart rate, heart-rate variability, and breathing rate for at least ten minutes at the one-month visit. Seventy-four mother-infant pairs were analyzed from 95 who returned for the visit. Regression analyses related infant outcomes to the four gestational exercise groups and participant characteristics.
Key FindingExercise-group intensity predicted infant heart rate, and gestational age predicted RMSSD, with both associations reported at p = .03. Nineteen recordings were excluded because the Hexoskin system could not interpret the data, and the thesis does not establish a clinical benefit for infants.
Data channels
Breathing RateHeart Rate
HexoskinArticleRespiratory & Infectious DiseaseClinical Medicine & SurgeryValidation & Methodology
Hennepe, N. T., Steegh, V. L. J. M., Pouw, M. H., Roukema, J., De Kleuver, M., & Van Hooff, M. L. (2024). Pulmonary function in patients with adolescent idiopathic scoliosis: an explorative study of a wearable smart shirt as a measurement instrument. Spine Deformity. https://doi.org/10.1007/s43390-024-00938-4
SummaryThis exploratory feasibility study assessed Hexoskin monitoring during a standardized walk with stair climbing in adolescents with idiopathic scoliosis. Five participants completed 31–35 minutes of walking while the shirt recorded tidal volume, breathing rate, minute ventilation, and heart rate. Comfort scores ranged from 6 to 9 out of 10. The shirt was not calibrated against spirometry, and the five-person descriptive study does not establish measurement accuracy.
Key FindingContinuous Hexoskin monitoring was feasible and generally well tolerated in five participants, but the study did not calibrate the shirt against spirometry or establish measurement accuracy.
Teckchandani, T. A., Neary, J. P., Andrews, K. L., Maguire, K. Q., Jamshidi, L., Nisbet, J., Shields, R. E., Afifi, T. O., Sauer-Zavala, S., Lix, L. M., Krakauer, R. L., Asmundson, G. J. G., Krätzig, G. P., & Carleton, R. N. (2023). Cardioautonomic lability assessed by heart rate variability changes in Royal Canadian Mounted Police cadets during the cadet training program. Frontiers in Psychology. https://doi.org/10.3389/fpsyg.2023.1144783
SummaryThis longitudinal study assessed cardiac-autonomic variability during the 26-week Royal Canadian Mounted Police Cadet Training Program. Hexoskin garments recorded daily three-lead ECG, and 31 heart-rate-variability parameters were calculated from resting recordings in Kubios. A total of 157 cadets participated, while the anxiety-group tables reported 95 screen-negative and 12 screen-positive cadets. Of 6,699 collected recordings, 2,871 met the analysis criteria.
Key FindingThe standard deviation of the LF:HF ratio derived from Hexoskin ECG during training was lower in GAD-7 screen-positive cadets than in screen-negative cadets, 1.28 versus 2.58 (P=.035), while the average LF:HF ratio did not differ. More than half of the recordings were excluded for signal artifact, and the article does not explicitly identify the 107 cadets in the comparison tables as the full analyzed cohort.
Eine explorative Studie zur Validität der Herzfrequenzmessung mittels Smart Shirts bei Laufsportlern
Alfuth, M., Teeuwen, M., Klemp, J., & Skonetzki-Cheng, S. (2021). Eine explorative Studie zur Validität der Herzfrequenzmessung mittels Smart Shirts bei Laufsportlern. German Journal of Sports Medicine.
Data channels
Heart Rate
HexoskinReportRespiratory & Infectious DiseaseOccupational Health & Human FactorsData Science & Artificial Intelligence
Performance monitoring by simultaneous sensing of internal gas exchange and respiration patterns - Pythia phase II
Stassinos, E., Sonnon, S., Wong, H., & Berlanga, A. (2021). Performance monitoring by simultaneous sensing of internal gas exchange and respiration patterns - Pythia phase II. Nevada National Security Site, Site-Directed Research and Development Program (DOE/NV/03624--1181).
Prediction of Oxygen Uptake and its Dynamics by Wearable Sensors During Activities of Daily Living
Beltrame, T. (2016). Prediction of Oxygen Uptake and its Dynamics by Wearable Sensors During Activities of Daily Living. University of Waterloo (Doctor of Philosophy in Kinesiology).
SummaryThis thesis investigated wearable-sensor prediction of oxygen uptake and oxygen-uptake dynamics during walking and activities of daily living across several separate studies. In the Hexoskin studies, acceleration, ECG, and respiratory signals supplied heart rate, ventilation, breathing frequency, and movement features for machine-learning models, while gas analysis provided the oxygen-uptake reference. One unsupervised study analyzed 13 healthy men over up to four days of daily activity, with sensors worn 6.3 ± 1.4 hours per day. Predicted and measured oxygen uptake were significantly correlated in the reported analyses.
Key FindingOne daily-activity analysis reported r = 0.87 between predicted and measured oxygen uptake, while another reported r = 0.69. The studies used small, mostly young and male cohorts, and three additional participants were excluded because of respiratory-band or ECG-electrode problems.
V., D. P. T., Falk, T. H., & Maier, M. (2016). MS-QI: A Modulation Spectrum-Based ECG Quality Index for Telehealth Applications. IEEE Transactions on Biomedical Engineering, vol. 63, no. 8. https://doi.org/10.1109/tbme.2014.2355135
SummaryThis methods study proposed a modulation-spectrum ECG quality index for telehealth recordings. Hexoskin supplied single-channel textile ECG and actimetry from three users during sitting, walking and running, alongside synthetic and public ECG datasets. The proposed MS-QI was compared with kurtosis and an in-band-to-out-of-band power ratio. Hexoskin was a data source for algorithm evaluation rather than the device under evaluation.
Key FindingOn the Hexoskin dataset, MS-QI correlated with actimetry at Pearson ρ=-0.94 and Spearman ρ=-0.92, outperforming the reported Pearson correlations for the comparator indices. The Hexoskin participant count and protocol were limited, and actimetry was used as the quality reference rather than expert clinical annotation.
Raw signals
AccelerationECG
Data channels
Activity
AstroskinConference PaperOccupational Health & Human FactorsValidation & Methodology
Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform
Toscano, W., Cowings, P., Sullivan, P., Martin, A., Roy, J., Krihak, M., Winther, S., Hanson, A., & Shaw, T. (2017). Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform. NASA Human Research Program Investigators' Workshop.
SummaryResearchers tested an Astroskin prototype during 30-day simulated missions in NASA’s Human Exploration Research Analog. They assessed whether crew members could record usable physiological signals during exercise and whether monitoring could continue for 24 hours.
Key FindingExercise signals were usable in most cases. Storing data on the Astroskin module supported 24-hour monitoring; real-time Bluetooth streaming shortened the recording time.
Valente, L., Quaresma, C., & Quintão, C. (2026). Multimodal Analysis of Human Movement Patterns Using a Smart Wearable T-Shirt and Force Platform. Proceedings of the 19th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2026) - Volume 1: BIOSIGNALS. https://doi.org/10.5220/0014473900004070
van Leuteren, R., Fabius, T., de Jongh, F., van der Valk, P., Brusse-Keizer, M., & van der Palen, J. (2017). Detecting dynamic hyperinflation in COPD patients using a smart shirt: a pilot study. European Respiratory Journal 50 (suppl 61): PA2214. https://doi.org/10.1183/1393003.congress-2017.pa2214
Raw signals
Respiration
HexoskinConference PaperExercise Physiology & Sports ScienceOccupational Health & Human Factors
van Rheden, V., Burr, L. A., Harbour, E., Finkenzeller, T., Meschtscherjakov, A., & Tscheligi, M. (2021). Run, Beep, Breathe: Exploring the Effects on Adherence and User Experience of 5 Breathing Instruction Sounds while Running. Audio Mostly 2021 (AM '21), September 1–3, 2021, virtual/Trento, Italy. https://doi.org/10.1145/3478384.3478412
Raw signals
AccelerationRespiration
Data channels
Breathing RateHeart Rate
HexoskinArticleExercise Physiology & Sports ScienceOccupational Health & Human Factors
van Rheden, V., Harbour, E., Finkenzeller, T., & Meschtscherjakov, A. (2024). Into the Rhythm: Evaluating Breathing Instruction Sound Experiences on the Run with Novice Female Runners. Multimodal Technologies and Interaction. https://doi.org/10.3390/mti8040025
SummaryTwo exploratory within-participant studies evaluated breathing-instruction sounds during treadmill running. Study 1 and study 2 each included 11 novice female runners. Hexoskin recorded respiration, heart rate, and acceleration to assess adherence to the breathing sounds. In study 1, each of five sound conditions included 5 minutes of running after a 10-minute warm-up. The small samples of female runners tested on a laboratory treadmill limit generalizability.
Key FindingWith respiration tracked by Hexoskin, mean absolute percentage error for breathing-rate stabilization was 1.16 ± 1.05% in study 1 and 1.9 ± 0.11% in study 2. Participants stayed attached to the instructed breathing rate for 86.81 ± 9.71% and 86.18 ± 11.96% of the time. All sounds scored below 5/10 on intention to use.
Raw signals
AccelerationRespiration
Data channels
Breathing RateHeart Rate
HexoskinConference AbstractNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Vebares, T. J., Miner, J., Haney, A. M., Sun, P., & Trull, T. J. (2021). Respiratory sinus arrhythmia and alcohol consumption in daily life. RSA Abstracts, Wiley supplement 2021, S1 (doi 10.1111/acer.14628). https://doi.org/10.1111/acer.14628
Raw signals
AccelerationECG
Data channels
Breathing Rate
HexoskinArticleNeuroscience, Sleep & CognitionClinical Medicine & Surgery
Verma, A., Hesterman, J. Y., Chazen, J. L., Holt, R., Connolly, P., Horky, L., Vallabhajosula, S., & Mozley, P. D. (2020). Intrathecal 99mTc-DTPA imaging of molecular passage from lumbar cerebrospinal fluid to brain and periphery in humans. Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring. https://doi.org/10.1002/dad2.12030
SummaryThis imaging study followed intrathecal tracer movement in 15 healthy volunteers using serial planar imaging and SPECT/CT. Hexoskin monitored heart rate, ventilation and physical activity, and its accelerometer was used after the study to check compliance with the physical-activity limit. The smart shirt was a monitoring aid rather than the intervention or primary measurement system. Hexoskin wear duration was not reported.
Key FindingThe publication reports tracer-distribution and urinary-excretion results but no Hexoskin physiological outcomes. The methods describe subgroup counts totaling 13 rather than the stated 15 volunteers, and the article does not reconcile the remaining two participants.
Raw signals
Acceleration
Data channels
Activity
AstroskinConference PaperValidation & MethodologyExercise Physiology & Sports ScienceOccupational Health & Human Factors
Villa, J., Shaw, T., Toscano, W., & Cowings, P. (2018). Evaluation of Astroskin Bio-monitor during high intensity physical activities. Memorias del XLI Congreso Nacional de Ingeniería Biomédica. https://doi.org/10.24254/cnib.18.49
SummaryFour participants exercised on a treadmill, a cycle and a rowing machine while researchers evaluated an Astroskin prototype. The team compared its heart-rate readings with a Polar monitor and with heart rate calculated in DADiSP.
Key FindingHeart-rate readings were generally highly correlated. During one participant’s treadmill test, Astroskin tracked the DADiSP result but diverged from Polar, so the overall correlation did not hold for every comparison.
Villar, R., Beltrame, T., & Hughson, R. L. (2015). Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities. Appl. Physiol. Nutr. Metab.. https://doi.org/10.1139/apnm-2015-0140
SummaryThis two-day laboratory study validated Hexoskin during lying, sitting, standing and walking. Twenty healthy adults enrolled, although some analyses included 16, 18 or 19 participants after exclusions. Heart rate, breathing rate, tidal volume, minute ventilation and hip-motion intensity were compared with laboratory references. The final minute of each steady-state activity trial was analyzed.
Key FindingHexoskin heart rate and breathing rate showed intraclass correlations of 0.96–0.99 and 0.96–1.00, respectively, with narrow reported limits of agreement. Hip-motion intensity showed intraclass correlations of 0.80–0.97, while tidal volume and minute ventilation tracked reference changes in arbitrary units. Results from healthy young volunteers and short laboratory activities do not establish clinical or free-living performance.
Pont, V. (2014). Mapper l'effort physique grâce au Hexoskin. HES-SO Valais-Wallis.
SummaryThis thesis developed an Android and web application for mapping physical effort during sports sessions. Smartphone GPS supplied route and movement information, while the web application retrieved Hexoskin data through the REST API and linked average pulse and pulse heat maps to the route. The interface also displayed duration, distance, speed, calories, and session comparisons. The thesis describes a software implementation and does not report a participant cohort or physiological validation study.
Key FindingThe project demonstrated a software workflow for combining mapped activity with Hexoskin pulse data. Without a reported validation cohort or performance metrics, it should not be presented as evidence of physiological accuracy or training benefit.
Vollmer, M., Bläsing, D., & Kaderali, L. (2019). Alignment of Multi-Sensored Data: Adjustment of Sampling Frequencies and Time Shifts. Computing in Cardiology Conference (CinC). https://doi.org/10.22489/cinc.2019.031
Raw signals
ECG
HexoskinPreprintData Science & Artificial IntelligenceClinical Medicine & Surgery
Towards Identifying the Optimal Timing for Near Real-Time Smoking Interventions Using Commercial Wearable Devices
Weber, T., Ferrin, M., Chau, D. H., Ahmed, S., & Sharmin, M. (2018). Towards Identifying the Optimal Timing for Near Real-Time Smoking Interventions Using Commercial Wearable Devices. Manuscript submitted to ACM.
Webster, E., Sukaviriya, N., Chang, H. Y. H., & Kozloski, J. (2017). Predicting cognitive states from wearable recordings of autonomic function. IBM J. RES. & DEV.. https://doi.org/10.1147/jrd.2017.2648698
SummaryThis preliminary study tested personalized prediction of self-labelled cognitive states from Hexoskin physiological and movement data. Five people were recorded during daily work, four were included in classification, and only three showed reliably better-than-chance performance. Random-forest accuracy averaged 61.3% and k-nearest-neighbor accuracy 57% with 10-minute look-back windows. The proof-of-concept sample and self-labelled outcomes do not establish general or prospective performance.
Key FindingIn a cognitive-state classification study using Hexoskin signals, only three of four analyzed participants showed reliably better-than-chance classification; mean accuracy was 61.3% for random forest and 57% for k-nearest neighbors.
Wierschem, D. C., Jimenez, J. A., & Mediavilla, F. A. M. (2020). A motion capture system for the study of human manufacturing repetitive motions. The International Journal of Advanced Manufacturing Technology. https://doi.org/10.1007/s00170-020-05822-9
SummaryThis manufacturing-methods study combined optical motion capture with wearable physiological monitoring to analyze repetitive work. A worker wore a Hexoskin bioshirt during demonstration tasks, while a separate lifting experiment involved 11 male participants. The shirt recorded heart rate, ventilation and breathing rate each second alongside motion data. The work focused on motion segmentation, dynamic-time-warping patterns and statistical process control rather than validating the garment.
Key FindingThe lifting treatments produced mean heart rates from 134.55 to 159.12 beats/min and mean breathing rates from 18.88 to 26.20 breaths/min. The physiological values were descriptive inputs to the manufacturing-analysis framework, so the study does not establish diagnostic, fatigue-prediction or device-validation performance.
Data channels
Breathing RateHeart RateMinute Ventilation
HexoskinStudy ProtocolOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Wilbur, R. E., Griffin, J. S., Sorensen, M., & Furberg, R. D. (2018). Establishing Digital Biomarkers for Occupational Health Assessment in Commercial Salmon Fishermen: Protocol for a Mixed-Methods Study. JMIR Research Protocols. https://doi.org/10.2196/10215
Data channels
ActivityHeart Rate
HexoskinArticleExercise Physiology & Sports ScienceOccupational Health & Human Factors
Wilkes, M., MacInnis, M. J., Hawkes, L. A., Massey, H., Eglin, C., & Tipton, M. J. (2018). The Physiology of Paragliding Flight at Moderate and Extreme Altitudes. High Altitude Medicine & Biology. https://doi.org/10.1089/ham.2017.0127
SummaryThis field study described physiological responses during paragliding at moderate and extreme altitudes and during aerial manoeuvres. Hexoskin recorded ECG, respiratory movement and acceleration in four moderate-altitude pilots, two extreme-altitude pilots and two manoeuvre pilots. Flight phases were analyzed in five-minute sections, with additional flight data from 17 Flymaster users. All monitored pilots were male, and group sizes were small.
Key FindingPilots monitored with Hexoskin had a higher mean heart rate at extreme than at moderate altitude (112 vs 98 beats/min, p = 0.048). Oxygen consumption during takeoff was measured separately by a metabolic system.
Wilson, S. L., Bradley, R., Shin, J. M., Trafton, B., Quintana, R., & Parker, D. L. (2016). Heart Rate Variability in Aerobically Trained Subjects vs. Untrained Subjects in Hypoxic and Normoxic Conditions. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000485934.19628.11
Raw signals
ECG
Metrics
SDNN
HexoskinArticleOccupational Health & Human FactorsClinical Medicine & Surgery
Wolfe, A. H. J., Hinds, P. S., du Plessis, A. J., Gordish-Dressman, H., Arnold, R. M., & Soghier, L. (2022). Defining Objective Measures of Physician Stress in Simulated Critical Communication Encounters. Critical Care Explorations. https://doi.org/10.1097/cce.0000000000000721
SummaryThis simulation study examined objective and self-reported stress during critical physician communication encounters. Twelve participants wore Hexoskin shirts throughout a one-day course, including a 30-minute baseline and six simulated encounters. State anxiety increased by 8 points for observers and 12 points for participants in the hot-seat role, while several heart-rate-variability measures differed by role. The small simulation study did not validate Hexoskin against a reference or establish effects in clinical encounters.
Key FindingIn simulated encounters that used Hexoskin for physiological monitoring, self-reported state anxiety increased by 8 points for observers and 12 points for hot-seat participants (p = 0.021); the result comes from 12 participants in simulated encounters.
HexoskinArticleOccupational Health & Human FactorsNeuroscience, Sleep & Cognition
Wolfe, A. H. J., Hinds, P. S., du Plessis, A. J., Gordish-Dressman, H., Freedenberg, V., & Soghier, L. (2024). Mindfulness Exercises Reduce Acute Physiologic Stress Among Female Clinicians. Critical Care Explorations. https://doi.org/10.1097/cce.0000000000001171
SummaryThe study assessed the feasibility of using the Hexoskin smart shirt as an objective stress measure. Participants included 13 clinicians, including physicians, a nurse practitioner, and female pediatric nurses. The Hexoskin smart shirt recorded HRV continuously during an 8-hour mindfulness training day. During body scan exercises, RMSSD was 35.68 ± 3.79 compared to 21.90 ± 2.56 at baseline (p = 0.026).
Key FindingDuring a feasibility study that also used Hexoskin for physiological monitoring, questionnaire-based STAI scores decreased from 44.6 to 27.2 (p < 0.001). The study assessed the feasibility of measurement rather than the accuracy of the garment against a reference.
HexoskinArticleClinical Medicine & SurgeryOccupational Health & Human Factors
Wolfe, A. H. J., Hinds, P. S., du Plessis, A. J., Gordish-Dressman, H., & Soghier, L. (2026). Describing the Impact of Physician End-of-Life Communication Training on Simulated Stress Using a Novel Stress Marker. Am J Hosp Palliat Care. https://doi.org/10.1177/10499091251330279
SummaryThis study describes the impact of physician end-of-life communication training on simulated stress using a novel stress marker. The study included 21 participants. The Hexoskin smart shirt was used to obtain baseline and in-simulation heart rate variability as the objective stress marker. Data were analyzed in 5-min heart rate variability epochs from a 30-min baseline before a 1-day retreat and three simulated encounters. The Hexoskin smart shirt was not evaluated against a reference.
Key FindingAmong residents monitored with Hexoskin, those with end-of-life care exposure had decreases in SDNN and RMSSD (P < 0.0001, P = 0.006).
Raw signals
ECG
HexoskinStudy ProtocolOccupational Health & Human FactorsValidation & Methodology
Wong, S., Cumming, T., MacQuarrie, A., Bull, R., Robertson, C., Saha, M., McFarland, L., & Logan, H. (2022). Holistic measurement of early childhood educators' well-being: a protocol. International Journal of Research & Method in Education. https://doi.org/10.1080/1743727x.2022.2128746
Data channels
Activity
HexoskinConference AbstractClinical Medicine & SurgeryRespiratory & Infectious Disease
Yawn, B., Pasquale, C., Houlihan, M., McCreary, G., Malanga, E., Plummer, R., Tortorich, D., Row, R., Giordano, S., & Sanjar, S. (2019). Impact of Including a Patient Investigator in a Pilot Observational Study. CHEST. https://doi.org/10.1016/j.chest.2019.08.1422
HexoskinConference PaperOccupational Health & Human FactorsData Science & Artificial Intelligence
Yiiong, S. P., Ting, H. Y., Tan, D. Y. W., & Chia, R. (2019). Investigation of Relation between Sport's Motion and Heart Rate Variability (HRV) Based on Biometric Parameters. IOP Conference Series: Materials Science and Engineering 495 (CUTSE). https://doi.org/10.1088/1757-899x/495/1/012015
Yong, T. H., & Tan, D. Y. W. (2017). Preliminary Investigation of Movement-Heart Rate Relationship Using Kinect-Based Badminton Performance Analysis. 2017 International Conference on Robotics, Automation and Sciences (ICORAS). https://doi.org/10.1109/icoras.2017.8308052
Data channels
Heart Rate
HexoskinArticleNeuroscience, Sleep & CognitionOccupational Health & Human Factors
Yuda, E., Yoshida, Y., & Hayano, J. (2020). Smart Shirt Respiratory Monitoring to Detect Car Driver Drowsiness. International Journal of Affective Engineering. https://doi.org/10.5057/ijae.ijae-d-20-00015
SummaryThis study tested whether respiratory variability from a Hexoskin shirt could help detect driver drowsiness. Nine healthy participants contributed 2,359 minutes of driving, and complex demodulation was used to derive respiratory frequency and variability. Respiratory-rate variability rose progressively from four minutes before heart-rate Dip & Waves events, while no heart-rate-variability metric showed a significant time trend. The small study used Dip & Waves as a drowsiness marker and did not test real-time warning performance.
Key FindingRespiratory-rate variability derived from Hexoskin breathing signals increased from four minutes before Dip & Waves events, while no heart-rate-variability measure showed a significant time trend; nine healthy drivers were studied.
Zhao, X., Li, Y., Zhang, L., Wang, J., Jialin, A., An, Q., Fu, Y., Yao, C., & Deng, W. (2026). Sighing Dynamics as a Candidate Digital Biomarker for Anxiety in Daily Life Using Wearable Respiratory Monitoring: Intensive Longitudinal Study. JMIR Formative Research. https://doi.org/10.2196/89485
SummaryThis intensive longitudinal study paired ecological momentary assessment with continuous Hexoskin respiratory monitoring in daily life. Thirty-eight adults enrolled, and 33 contributed enough synchronized data for analysis across four 36-hour monitoring blocks. Breath-by-breath tidal-volume data were used to identify sighs in five-minute windows before anxiety ratings. The study examined state and trait anxiety associations while also assessing wear time, signal quality and linked-data coverage.
Key FindingIn an ambulatory study that paired anxiety reports with Hexoskin respiratory monitoring, higher trait anxiety was associated with a lower sigh proportion (OR 0.80, 95% CI 0.74–0.87; P<.001), while the within-person anxiety-by-group interaction was significant (OR 1.14, 95% CI 1.03–1.26; P=.01). The protocol achieved 79.5% EMA completion, 84.1% high-quality respiratory samples and 81.1% EMA-respiratory linkage. Five enrolled participants were excluded for too few valid synchronized windows, so the findings require confirmation in larger cohorts.
Zhu, J., Gascho, J., Kerhoulas, Z., Cheng, J., Kim, H., Brueckner, S., Bhambhani, C., Ashton-Miller, J., & Li, P. (2024). Fulgura Frango: Breath-Extended Harpsichord. Music Proceedings of the International Conference on New Interfaces for Musical Expression (NIME'24), Utrecht.
Zwilling, M., Romano, A., Hoffman, H., Lotan, M., & Tesler, R. (2022). Development and validation of a system for the prediction of challenging behaviors of people with autism spectrum disorder based on a smart wearable shirt: A mixed-methods design. Frontiers in Behavioral Neuroscience. https://doi.org/10.3389/fnbeh.2022.948184
Contact Hexoskin
Tell us about your project, research needs, or questions and our team will follow up.
Loading form…
Message sent
Thank you for contacting Hexoskin. Your message was submitted successfully and our team will follow up.
Request Publications Summary
Submit your details and the Hexoskin team will follow up with the requested publications summary.
Loading form…
Request received
Thank you. Your publications summary request was submitted successfully.
Export Filtered Research
Submit your details to generate a branded document containing the publications currently displayed.
Loading form…
HexoskinDocument Preview
Include
Hexoskin
Scientific Publications Research
Custom filtered bibliography based on your specific criteria.