Heart
3-lead ECG and heart rate, FDA-cleared. Heart rate variability for research.
Protocol Feasibility
Our clinical team reviews the protocol with you before the first participant: the measures, the wear schedule, the participant burden, and the site workflow, drawing on studies already run with the garment.
3-lead ECG and heart rate, FDA-cleared. Heart rate variability for research.
Respiratory rate, FDA-cleared. Tidal volume and minute ventilation for research.
Activity, FDA-cleared. Steps, body position, and sleep for research.
Hexoskin OneView, the participant app with ePROs, and secure data hosting.
Feasibility questions slow a study when they surface after the first participant. Hexoskin answers them during protocol design: which measures the garment supports for your population, how many hours of wear the analysis needs, what schedule participants can sustain, and how sites will fit, sync, and follow compliance. The study starts with a plan that already works, without adding a separate phase.
The measures the protocol needs, matched to what the platform records for your population.
Recording hours and timing that the analysis needs and participants can sustain.
Fitting, routine, sync, and support, planned for the cohort.
Training, compliance follow-up, and escalation, set before the first participant.

FDA 510(k) Cleared · Available for Research
Cardiorespiratory monitoring that patients wear like everyday clothing. The Hexoskin Medical System (HMS) records, displays, and stores 3-lead ECG, heart rate, respiratory rate, and activity, at home or in a healthcare facility, with textile sensors instead of adhesive electrodes.
For research, the HMS recorder and shirt can be configured to follow participants living with cardiovascular, respiratory, neurological, sleep, oncology, and rare conditions, day and night, with as little burden as possible.
The FDA clearance covers the recording, display, and storage of three-lead ECG, heart rate, respiratory rate, and activity in adults, as described in K243981. The research configuration and its derived measures are for research use and are not part of the clearance. HMS does not produce alarms, is not intended for real-time patient monitoring, does not provide automatic analysis or diagnosis, is not an apnea monitor, and is not intended for use with a pacemaker or as life-supporting equipment for critical care patients.
Tell us about the protocol, the population, and the setting. Our clinical team will reply with the configuration, the measures, and the next step for your program.
Every output the Hexoskin Medical System records or computes. Select a card to read its unit and definition, filter by data group or measurement area, or search for a measure.
Shirt and recorder for continuous cardiac, respiratory, and movement recording, with textile sensors and no adhesive electrodes.
3 outputs with definitions
Heart rate: average over the last 16 heart beats.
RR interval: time between two heart beat detections, calculated for every QRS event. Saved at the center of the QRS complex.
NN interval: Time between two heart beat detections, calculated for every QRS event.
Energy Expenditure Estimate: Total energy based on ECG, using the Mifflin and Keytel equation. Adjusted for the weight, height, sex, HRmax and HRmin of the user.
7 outputs with definitions
Heart rate status: quality of the heart rate signal.
QRS status: status of the last QRS detection.
6 outputs with definitions
13 outputs with definitions
6 outputs with definitions
2 outputs with definitions
Breathing rate: calculated over the last 7 respiration cycles.
Inspiration: detection of an inspiration onset event.
Expiration: detection of an expiration onset event.
Minute Ventilation: Volume of air per minute inspired in the last 7 complete respiration cycles. Based on the raw signal; for study reporting use minute_ventilation_adjusted.
Minute Ventilation, Adjusted: Volume of air per minute inspired in the last 7 complete respiration cycles, adjusted for the user profile.
Tidal Volume: Volume of air inspired in the last inspiration. Based on the raw signal; for study reporting use tidal_volume_adjusted.
Tidal Volume, Adjusted: Volume of air inspired in the last inspiration, adjusted for the user profile.
Breathing rate status: quality of the breathing rate signal.
5 outputs with definitions
8 outputs with definitions
8 outputs with definitions
Respiration Coefficient: Calculated from the adjusted minute ventilation and the adjusted tidal volume. Reflects the O2 input and CO2 output of the user.
Volume Expired: Maximum expired volume, standard test.
Acceleration: three-axis sensor with a 0.004 g resolution.
Activity: signal based on the accelerometer intensity vector.
Cadence: averaged over the last 7 strides, based on the accelerometer.
Step: the number of steps since the beginning of a recording.
Device position: gives the onset of a position change.
4 outputs with definitions
4 outputs with definitions
Steps: Number of steps detected for that range (activity) or record.
Sleep phase: gives the onset of a sleep phase change.
Sleeper position: gives the onset of a position change.
8 outputs with definitions
7 outputs with definitions
Duration: Total duration of the range (activity or time range) or record.
Recorded Time: Number of heart rate samples at 1 Hz, that is, the number of seconds of signal stored on the server.
VO2 max: Estimation of maximum rate of oxygen consumption measured during a maximal aerobic exercise based on distance traveled. Can be calculated by completing the fitness test “12 minutes Run Fitness Test” on Hexoskin OneApp.
No outputs match these filters. Try another term.
Published studies show what participants and study teams achieved with the garment in comparable populations.
Support article on protecting the privacy and confidentiality of participants in clinical trials using Hexoskin.
Read the SourceHexoskin overview of wearable physiological recording in clinical development studies.
Read the SourceSensors, recorder, and outputs of the Hexoskin garment, with single-lead ECG, dual-band respiration, and acceleration.
Read the SourceBackground reading on continuous physiological monitoring in this field. Each paper is a free download.

Missing data weakens clinical trial conclusions. This paper shows where data loss comes from and how continuous recording between visits limits it when visits are missed or participants drop out.
Download the White Paper
The burden of chronic obstructive pulmonary disease, and how continuous respiratory recording supports telemonitoring programs and patient follow-up between visits.
Download the White Paper
A review of the techniques used to measure breathing, the growing range of digital health devices, and the role of scientific validation when selecting a wearable for respiratory monitoring.
Download the White PaperShare the protocol or the study outline. Our clinical team can review the measures, the wear schedule, and the site workflow with you.